/[lmdze]/trunk/Sources/dyn3d/Guide
ViewVC logotype

Log of /trunk/Sources/dyn3d/Guide

View Directory Listing Directory Listing


Sticky Revision:
(Current path doesn't exist after revision 253)

Revision 140 - Directory Listing
Modified Fri Jun 5 18:58:06 2015 UTC (8 years, 11 months ago) by guez
Changed unit of variables lat_min_guide and lat_max_guide from module
conf_guide_m from degrees to rad. Then we do not have to convert the
whole array rlat from rad to degrees in SUBROUTINE tau2alpha.

Removed some useless computations in inigeom.

Removed module coefils. Moved variables sddv, unsddv, sddu, unsddu,
eignfnu, eignfnv of module coefils to module inifgn_m. Downgraded
variables coefilu, coefilu2, coefilv, coefilv2, modfrstu, modfrstv of
module coefils to local variables of SUBROUTINE inifilr.

Write and read a 3-dimensional variable Tsoil in restartphy.nc and
startphy.nc instead of multiple variables for the different
subs-urfaces and soil layers. This does not allow any longer to
provide only the surface value in startphy.nc and spread it to other
layers. Instead, if necessary, pre-process the file startphy.nc to
spread the surface value.


Revision 139 - Directory Listing
Modified Tue May 26 17:46:03 2015 UTC (8 years, 11 months ago) by guez
dynetat0 read rlonu, rlatu, rlonv, rlatv, cu_2d, cv_2d, aire_2d from
"start.nc" and then these variables were overwritten by
inigeom. Corrected this. Now, inigeom does not compute rlonu, rlatu,
rlonv and rlatv. Moreover, cu_2d, cv_2d, aire_2d are not written to
"restart.nc". Since xprimu, xprimv, xprimm025, xprimp025, rlatu1,
rlatu2, yprimu1, yprimu2 are computed at the same time as rlonu,
rlatu, rlonv, rlatv, and since it would not be convenient to separate
those computations, we decide to write xprimu, xprimv, xprimm025,
xprimp025, rlatu1, rlatu2, yprimu1, yprimu2 into "restart.nc", read
them from "start.nc" and not compute them in inigeom. So, in summary,
"start.nc" contains all the coordinates and their derivatives, and
inigeom only computes the 2D-variables.

Technical details:

Moved variables rlatu, rlonv, rlonu, rlatv, xprimu, xprimv from module
comgeom to module dynetat0_m. Upgraded local variables rlatu1,
yprimu1, rlatu2, yprimu2, xprimm025, xprimp025 of procedure inigeom to
variables of module dynetat0_m.

Removed unused local variable yprimu of procedure inigeom and
corresponding argument yyprimu of fyhyp.

Moved variables clat, clon, grossismx, grossismy, dzoomx, dzoomy,
taux, tauy from module serre to module dynetat0_m (since they are read
from "start.nc"). The default values are now defined in read_serre
instead of in the declarations. Changed name of module serre to
read_serre_m, no more module variable here.

The calls to fxhyp and fyhyp are moved from inigeom to etat0.

Side effects in programs other than gcm: etat0 and read_serre write
variables of module dynetat0; the programs test_fxyp and
test_inter_barxy need more source files.

Removed unused arguments len and nd of cv3_tracer. Removed unused
argument PPSOL of LWU.

Bug fix in test_inter_barxy: forgotten call to read_serre.


Revision 137 - Directory Listing
Modified Wed May 6 15:51:03 2015 UTC (9 years ago) by guez
Removed unused argument missval in ma_fucoll_r[1-3]1, ma_fufill_r[1-3]1.

Split filtreg into two procedures: filtreg_scal and filtreg_v. I did
not like the test on the extent of the argument and there was no
common code between the two cases: jjm and jjm + 1. Also, it is
simpler now to just remove the argument "direct" from filtreg_v instead
of allowing it and then stopping the program if it is false.

Removed the computation of pkf in reanalyse2nat, was not used.

As a consequence of the split of filtreg, had to extract the
computation of pkf out of exner_hyb. This is clearer anyway because we
want to be able to call exner_hyb with any size in the first two
dimensions (as in test_disvert). But at the same time exner_hyb
required particular sizes for the computation of pkf. It was
awkward. The only computation of pkf is now in leapfrog.


Revision 135 - Directory Listing
Modified Thu Apr 30 14:22:32 2015 UTC (9 years ago) by guez
Use matmul in filtreg.

Revision 134 - Directory Listing
Modified Wed Apr 29 15:47:56 2015 UTC (9 years ago) by guez
Sources inside, compilation outside.

Revision 132 - Directory Listing
Modified Fri Mar 20 16:31:06 2015 UTC (9 years, 2 months ago) by guez
Original Path: trunk/dyn3d/Guide
Removed procedure jacobi, which was a copy of the file from Numerical
Recipes in Fortran 77. Refer to the Numer_Rec_95 library instead.

There was a strange line in procedure coordij: j cannot be equal to 0
after the loop on j.


Revision 127 - Directory Listing
Modified Tue Feb 10 17:58:56 2015 UTC (9 years, 3 months ago) by guez
Original Path: trunk/dyn3d/Guide
clon and clat from module serre are now in rad instead of
degrees. They are only used in rad, so we do only one conversion when
we read them.


Revision 116 - Directory Listing
Modified Thu Dec 4 16:35:03 2014 UTC (9 years, 5 months ago) by guez
Original Path: trunk/dyn3d/Guide
In test_disvert, write output files before testing order of pressure
values, so we have more information if there is a problem.


Revision 115 - Directory Listing
Modified Fri Sep 19 17:36:20 2014 UTC (9 years, 8 months ago) by guez
Original Path: trunk/dyn3d/Guide
Extracted code from tau2alpha for first call into new procedure
init_tau2alpha. dxdys, dxdyu, dxdyv are now local variables if guide
computed by init_tau2alpha. This allows us to remove terrible argument
type of tau2alpha: we just give to tau2alpha the right dxdy and
rlat.

In module conf_guide_m, changed default values of tau_min_*, because
0.02 is too small for the default daystep = 240, iperiod = 5. Changed
default values of guide_[uv] to false. Moved variable ok_guide from
conf_gcm_m to conf_guide_m, ok_guide is no longer an input parameter,
it is computed from guide_*. Had then to move test on ok_guide and
day_step from conf_gcm_m to conf_guide_m. Added checks on input
nudging parameters in procedure conf_guide. Upgraded variable factt to
module conf_guide_m in order to check nudging parameters. Bug fix:
variable guide_q was not in namelist conf_guide_nml.

Removed unused variables aire_min, aire_max of MODULE guide_m.

Moved the call to conf_guide from guide to gcm. This was needed to
define ok_guide before getting into guide (since ok_guide is no longer
in conf_gcm_m). Moved test on grossismx and grossismy from tau2alpha
to guide. It is clearer now that only tau_max is used for a regular
grid, and we do not have to repeat this test in each call to
tau2alpha. In guide, we only call writefield when alpha is not a
constant.


Revision 114 - Directory Listing
Added Fri Sep 19 11:41:35 2014 UTC (9 years, 8 months ago) by guez
Original Path: trunk/dyn3d/Guide


  ViewVC Help
Powered by ViewVC 1.1.21