Parent Directory | Revision Log
Sticky Revision: |
Removed argument ierr of abort_gcm. It was always 1 and not used. Just encapsulated pres2lev into a module. Removed test on run_off in procedure calcul_fluxs. Useless. The test is always done just before in interfsurf_hq. Removed named constants rea and repsm in module suphec: never used.
Removed unused argument missval in ma_fucoll_r[1-3]1, ma_fufill_r[1-3]1. Split filtreg into two procedures: filtreg_scal and filtreg_v. I did not like the test on the extent of the argument and there was no common code between the two cases: jjm and jjm + 1. Also, it is simpler now to just remove the argument "direct" from filtreg_v instead of allowing it and then stopping the program if it is false. Removed the computation of pkf in reanalyse2nat, was not used. As a consequence of the split of filtreg, had to extract the computation of pkf out of exner_hyb. This is clearer anyway because we want to be able to call exner_hyb with any size in the first two dimensions (as in test_disvert). But at the same time exner_hyb required particular sizes for the computation of pkf. It was awkward. The only computation of pkf is now in leapfrog.
Sources inside, compilation outside.
Removed unused variables lock_startdate and time_stamp of module calendar. Noticed that physiq does not change the surface pressure. So removed arguments ps and dpfi of subroutine addfi. dpfi was always 0. The computation of ps in addfi included some averaging at the poles. In principle, this does not change ps but in practice it does because of finite numerical precision. So the results of the simulation are changed. Removed arguments ps and dpfi of calfis. Removed argument d_ps of physiq. du at the poles is not computed by dudv1, so declare only the corresponding latitudes in dudv1. caldyn passes only a section of the array dudyn as argument. Removed variable niadv of module iniadvtrac_m. Declared arguments of exner_hyb as assumed-shape arrays and made all other horizontal sizes in exner_hyb dynamic. This allows the external program test_disvert to use exner_hyb at a single horizontal position.
Removed useless argument mode of subroutine read_reanalyse.
Removed option to guide surface pressure because it was not functional: psrea1 was not defined in procedure guide. Removed local variables psrea1 and psrea2 of procedure guide. ps becomes an "intent(in)" argument in guide. Removed case guide_p in guide. Removed variable guide_p of module conf_guide_m. Removed case guide_p and argument ps in read_reanalyse. Removed case guide_p and argument ps in reanalyse2nat.
In procedure conf_guide, replaced calls to getpar by reading a namelist. Removed file getparam.f, now unused. So getin of IOIPSL is now unused too. Removed files getincom.f, getincom2.f, cmpblank.f, find_sig.f, gensig.f and nocomma.f. Moved variables lat_min_guide and lat_max_guide from module tau2alpha_m to module conf_guide_m. Removed variables nivsig and nivsigs of module disvert_m. Instead, in initdynav and initfluxsto, directly wrote arithmetic sequence for verical axis, pending a better vertical axis. Removed variables nivsig and nivsigs of "(re)?.start.nc". In procedure exner_hyb, replaced p(:, :, 1) by equivalent ps.
Changed all ".f90" suffixes to ".f".
Moved everything out of libf.
Cleaning.
Changed name of module "comvert" to "disvert_m". Changed constant 1. to 0.3 in vertical sampling "strato".
Removed argument "pdteta" of "calfis", because it was not used. Created module "conf_guide_m", containing procedure "conf_guide". Moved module variables from "guide_m" to "conf_guide_m". In module "getparam", removed "ini_getparam" and "fin_getparam" from generic interface "getpar". Created module variables in "tau2alpha_m" to replace common "comdxdy".
Inlined procedure "pression". Split "guide.f90" into "guide.f90" and "tau2alpha.f90". Split "read_reanalyse.f" into single-procedure files in directory "Read_reanalyse". Useless copy of variables in "iniphysiq". Directly define module variables in "gcm" and remove procedure "iniphysiq". Added "pressure-altitude" in "test_disvert".
This form allows you to request diffs between any two revisions of this file. For each of the two "sides" of the diff, enter a numeric revision.
ViewVC Help | |
Powered by ViewVC 1.1.21 |