/[lmdze]/trunk/Sources/dyn3d/conf_gcm.f
ViewVC logotype

Contents of /trunk/Sources/dyn3d/conf_gcm.f

Parent Directory Parent Directory | Revision Log Revision Log


Revision 3 - (show annotations)
Wed Feb 27 13:16:39 2008 UTC (16 years, 2 months ago) by guez
Original Path: trunk/libf/dyn3d/conf_gcm.f90
File size: 4794 byte(s)
Initial import
1 module conf_gcm_m
2
3 ! This module is clean: no C preprocessor directive, no include line
4
5 IMPLICIT NONE
6
7 INTEGER:: nday= 10
8 ! Nombre de jours d'integration
9 ! On pourait aussi permettre des mois ou des annees !
10
11 integer:: day_step= 240 ! nombre de pas par jour, multiple de iperiod
12
13 integer:: iperiod= 5
14 ! periode pour le pas Matsuno (en pas de temps)
15
16 integer:: iapp_tracvl= 5
17 ! Should normally be equal to "iperiod"
18 ! frequence du groupement des flux (en pas de temps)
19
20 integer:: iconser= 240
21 ! periode de sortie des variables de controle
22 ! (En pas de temps)
23
24 integer:: iecri= 1 ! période d'écriture du fichier "dyn_hist.nc" (en jours)
25
26 integer:: idissip= 10 ! periode de la dissipation (en pas)
27
28 integer:: iphysiq= 5
29 ! Help = Periode de la physique en pas de temps de la dynamique.
30
31 integer:: dayref = 1 ! jour de l'année de l'état initial
32 ! (= 350 si 20 décembre par exemple)
33
34 integer:: anneeref = 1998 ! Annee de l'etat initial (avec 4 chiffres)
35
36 integer:: raz_date = 0 ! Remise a zero de la date initiale
37 ! 0 pas de remise a zero, on garde la date du fichier restart
38 ! 1 prise en compte de la date de gcm.def avec remise a zero
39 ! des compteurs de pas de temps
40
41 REAL:: periodav= 1.
42 ! periode de stockage fichier histmoy (en jour)
43
44 logical, save:: offline
45
46 contains
47
48 SUBROUTINE conf_gcm(clesphy0)
49
50 ! Auteurs : L. Fairhead, P. Le Van
51 ! Version du 29/04/97
52
53 ! Nouveaux paramètres nitergdiv, nitergrot, niterh, tetagdiv, tetagrot,
54 ! tetatemp ajoutés pour la dissipation.
55
56 ! Autre paramètre ajouté en fin de liste de tapedef : fxyhypb
57 ! Si fxyhypb = .TRUE., choix de la fonction à dérivée tangente
58 ! hyperbolique
59 ! Sinon, choix de fxynew, à dérivée sinusoïdale
60
61 ! On ne compare pas les valeurs des paramètres du zoom, grossismx,
62 ! grossismy, clon, clat, fxyhypb lues sur le fichier start avec
63 ! celles passées par run.def, au début du gcm.
64 ! Ces paramètres définissent entre autres la grille et doivent être
65 ! cohérents, sinon il y aura divergence du gcm.
66
67 use IOIPSL, only: getin
68 use dimens_m
69 use paramet_m
70 use comdissnew, only: read_comdissnew
71 use logic, only: iflag_phys, fxyhypb, ysinus, purmats, ok_guide
72 use serre, only: clon, clat, grossismx, grossismy, alphax, alphay, &
73 dzoomx, dzoomy, taux, tauy
74 use clesphys, only: ok_limitvrai, ok_orolf, iflag_con, nbapp_rad, &
75 ok_orodr, cycle_diurne, new_oliq, soil_model
76 use iniprint, only: lunout, read_iniprint
77
78 INTEGER, PARAMETER:: longcles = 20
79
80 REAL, intent(out), optional:: clesphy0(longcles)
81
82 namelist /conf_gcm_nml/dayref, anneeref, raz_date, nday, day_step, &
83 iperiod, iapp_tracvl, iconser, iecri, periodav, idissip, purmats, &
84 ok_guide, iflag_phys, iphysiq, cycle_diurne, soil_model, new_oliq, &
85 ok_orodr, ok_orolf, ok_limitvrai, nbapp_rad, iflag_con, clon, clat, &
86 grossismx, grossismy, dzoomx, dzoomy, taux, tauy
87
88 !------------------------------------
89
90 print *, "Call sequence information: conf_gcm"
91 call read_iniprint
92
93 print *, "Enter namelist 'conf_gcm_nml'."
94 read(unit=*, nml=conf_gcm_nml)
95 write(unit=*, nml=conf_gcm_nml)
96
97 call read_comdissnew
98
99 IF (lunout /= 5 .and. lunout /= 6) THEN
100 OPEN(lunout, FILE='lmdz.out')
101 ENDIF
102
103 if (present(clesphy0)) then
104 clesphy0(:) = 0.
105 clesphy0(1) = REAL(iflag_con)
106 clesphy0(2) = REAL(nbapp_rad)
107
108 IF (cycle_diurne) clesphy0(3) = 1.
109 IF (soil_model) clesphy0(4) = 1.
110 IF (new_oliq) clesphy0(5) = 1.
111 IF (ok_orodr) clesphy0(6) = 1.
112 IF (ok_orolf) clesphy0(7) = 1.
113 IF (ok_limitvrai) clesphy0(8) = 1.
114 end if
115
116 IF (grossismx < 1.) THEN
117 PRINT *, 'Error: grossismx < 1'
118 STOP 1
119 ELSE
120 alphax = 1. - 1. / grossismx
121 ENDIF
122 IF (grossismy < 1.) THEN
123 PRINT *, 'Error: grossismy < 1'
124 STOP 1
125 ELSE
126 alphay = 1. - 1. / grossismy
127 ENDIF
128 PRINT *, 'alphax = ', alphax
129 PRINT *, 'alphay = ', alphay
130
131 ! Key = fxyhypb
132 ! Desc = Fonction hyperbolique
133 ! Def = y
134 ! Help = Fonction f(y) hyperbolique si = .true.
135 ! sinon sinusoidale
136 fxyhypb = .TRUE.
137 CALL getin('fxyhypb', fxyhypb)
138
139 ! Key = ysinus
140 ! IF = !fxyhypb
141 ! Desc = Fonction en Sinus
142 ! Def = y
143 ! Help = Fonction f(y) avec y = Sin(latit.) si = .true.
144 ! sinon y = latit.
145 ysinus = .TRUE.
146 CALL getin('ysinus', ysinus)
147
148 ! Key = offline
149 ! Desc = Nouvelle eau liquide
150 ! Def = n
151 ! Help = Permet de mettre en route la
152 ! nouvelle parametrisation de l'eau liquide
153 offline = .FALSE.
154 CALL getin('offline', offline)
155 write(lunout, *)' offline = ', offline
156
157 END SUBROUTINE conf_gcm
158
159 end module conf_gcm_m

  ViewVC Help
Powered by ViewVC 1.1.21