--- trunk/Sources/dyn3d/dynredem0.f 2015/05/26 17:46:03 139 +++ trunk/Sources/dyn3d/dynredem0.f 2015/06/05 18:58:06 140 @@ -40,6 +40,10 @@ INTEGER idim_s, idim_sig INTEGER dimid_temps INTEGER ncid, varid + integer varid_controle, varid_rlonu, varid_rlatu, varid_rlonv, varid_rlatv + integer varid_xprimu, varid_xprimv, varid_xprimm025, varid_xprimp025 + integer varid_rlatu1, varid_rlatu2, varid_yprimu1, varid_yprimu2, varid_ap + integer varid_bp, varid_presnivs, varid_phisinit REAL zjulian, hours INTEGER yyears0, jjour0, mmois0 @@ -104,48 +108,50 @@ ! Definir et enregistrer certains champs invariants: - CALL nf95_def_var(ncid, 'controle', nf90_float, idim_index, varid) - CALL nf95_put_att(ncid, varid, 'title', 'Parametres de controle') + CALL nf95_def_var(ncid, 'controle', nf90_float, idim_index, varid_controle) + CALL nf95_put_att(ncid, varid_controle, 'title', 'Parametres de controle') - CALL nf95_def_var(ncid, 'rlonu', nf90_float, idim_rlonu, varid) - CALL nf95_put_att(ncid, varid, 'title', 'Longitudes des points U') + CALL nf95_def_var(ncid, 'rlonu', nf90_float, idim_rlonu, varid_rlonu) + CALL nf95_put_att(ncid, varid_rlonu, 'title', 'Longitudes des points U') - CALL nf95_def_var(ncid, 'rlatu', nf90_float, idim_rlatu, varid) - CALL nf95_put_att(ncid, varid, 'title', 'Latitudes des points U') + CALL nf95_def_var(ncid, 'rlatu', nf90_float, idim_rlatu, varid_rlatu) + CALL nf95_put_att(ncid, varid_rlatu, 'title', 'Latitudes des points U') - CALL nf95_def_var(ncid, 'rlonv', nf90_float, idim_rlonv, varid) - CALL nf95_put_att(ncid, varid, 'title', 'Longitudes des points V') + CALL nf95_def_var(ncid, 'rlonv', nf90_float, idim_rlonv, varid_rlonv) + CALL nf95_put_att(ncid, varid_rlonv, 'title', 'Longitudes des points V') - CALL nf95_def_var(ncid, 'rlatv', nf90_float, idim_rlatv, varid) - CALL nf95_put_att(ncid, varid, 'title', 'Latitudes des points V') + CALL nf95_def_var(ncid, 'rlatv', nf90_float, idim_rlatv, varid_rlatv) + CALL nf95_put_att(ncid, varid_rlatv, 'title', 'Latitudes des points V') - CALL nf95_def_var(ncid, 'xprimu', nf90_float, idim_rlonu, varid) - CALL nf95_put_att(ncid, varid, 'title', 'dx / dX aux points u') + CALL nf95_def_var(ncid, 'xprimu', nf90_float, idim_rlonu, varid_xprimu) + CALL nf95_put_att(ncid, varid_xprimu, 'title', 'dx / dX aux points u') - CALL nf95_def_var(ncid, 'xprimv', nf90_float, idim_rlonv, varid) - CALL nf95_put_att(ncid, varid, 'title', 'dx / dX aux points v') + CALL nf95_def_var(ncid, 'xprimv', nf90_float, idim_rlonv, varid_xprimv) + CALL nf95_put_att(ncid, varid_xprimv, 'title', 'dx / dX aux points v') - CALL nf95_def_var(ncid, 'xprimm025', nf90_float, idim_rlonu, varid) - CALL nf95_def_var(ncid, 'xprimp025', nf90_float, idim_rlonu, varid) + CALL nf95_def_var(ncid, 'xprimm025', nf90_float, idim_rlonu, & + varid_xprimm025) + CALL nf95_def_var(ncid, 'xprimp025', nf90_float, idim_rlonu, & + varid_xprimp025) - CALL nf95_def_var(ncid, 'rlatu1', nf90_float, idim_rlatv, varid) - CALL nf95_def_var(ncid, 'rlatu2', nf90_float, idim_rlatv, varid) - CALL nf95_def_var(ncid, 'yprimu1', nf90_float, idim_rlatv, varid) - CALL nf95_def_var(ncid, 'yprimu2', nf90_float, idim_rlatv, varid) + CALL nf95_def_var(ncid, 'rlatu1', nf90_float, idim_rlatv, varid_rlatu1) + CALL nf95_def_var(ncid, 'rlatu2', nf90_float, idim_rlatv, varid_rlatu2) + CALL nf95_def_var(ncid, 'yprimu1', nf90_float, idim_rlatv, varid_yprimu1) + CALL nf95_def_var(ncid, 'yprimu2', nf90_float, idim_rlatv, varid_yprimu2) - CALL nf95_def_var(ncid, 'ap', nf90_float, idim_sig, varid) - CALL nf95_put_att(ncid, varid, 'title', 'Coefficient A pour hybride') + CALL nf95_def_var(ncid, 'ap', nf90_float, idim_sig, varid_ap) + CALL nf95_put_att(ncid, varid_ap, 'title', 'Coefficient A pour hybride') - CALL nf95_def_var(ncid, 'bp', nf90_float, idim_sig, varid) - CALL nf95_put_att(ncid, varid, 'title', 'Coefficient B pour hybride') + CALL nf95_def_var(ncid, 'bp', nf90_float, idim_sig, varid_bp) + CALL nf95_put_att(ncid, varid_bp, 'title', 'Coefficient B pour hybride') - CALL nf95_def_var(ncid, 'presnivs', nf90_float, idim_s, varid) + CALL nf95_def_var(ncid, 'presnivs', nf90_float, idim_s, varid_presnivs) ! Geopentiel au sol: CALL nf95_def_var(ncid, 'phisinit', nf90_float, & - (/idim_rlonv, idim_rlatu/), varid) - CALL nf95_put_att(ncid, varid, 'title', 'Geopotentiel au sol') + (/idim_rlonv, idim_rlatu/), varid_phisinit) + CALL nf95_put_att(ncid, varid_phisinit, 'title', 'Geopotentiel au sol') ! Definir les variables pour pouvoir les enregistrer plus tard: @@ -183,56 +189,23 @@ CALL nf95_enddef(ncid) - CALL nf95_inq_varid(ncid, 'controle', varid) - CALL nf95_put_var(ncid, varid, tab_cntrl) - - CALL nf95_inq_varid(ncid, 'rlonu', varid) - CALL nf95_put_var(ncid, varid, rlonu) - - CALL nf95_inq_varid(ncid, 'rlatu', varid) - CALL nf95_put_var(ncid, varid, rlatu) - - CALL nf95_inq_varid(ncid, 'rlonv', varid) - CALL nf95_put_var(ncid, varid, rlonv) - - CALL nf95_inq_varid(ncid, 'rlatv', varid) - CALL nf95_put_var(ncid, varid, rlatv) - - CALL nf95_inq_varid(ncid, 'xprimu', varid) - CALL nf95_put_var(ncid, varid, xprimu) - - CALL nf95_inq_varid(ncid, 'xprimv', varid) - CALL nf95_put_var(ncid, varid, xprimv) - - CALL nf95_inq_varid(ncid, 'xprimm025', varid) - CALL nf95_put_var(ncid, varid, xprimm025) - - CALL nf95_inq_varid(ncid, 'xprimp025', varid) - CALL nf95_put_var(ncid, varid, xprimp025) - - call NF95_INQ_VARID (ncid, "rlatu1", varid) - call NF95_PUT_VAR(ncid, varid, rlatu1) - - call NF95_INQ_VARID (ncid, "rlatu2", varid) - call NF95_PUT_VAR(ncid, varid, rlatu2) - - CALL nf95_inq_varid(ncid, 'yprimu1', varid) - CALL nf95_put_var(ncid, varid, yprimu1) - - CALL nf95_inq_varid(ncid, 'yprimu2', varid) - CALL nf95_put_var(ncid, varid, yprimu2) - - CALL nf95_inq_varid(ncid, 'ap', varid) - CALL nf95_put_var(ncid, varid, ap) - - CALL nf95_inq_varid(ncid, 'bp', varid) - CALL nf95_put_var(ncid, varid, bp) - - CALL nf95_inq_varid(ncid, 'presnivs', varid) - CALL nf95_put_var(ncid, varid, presnivs) - - CALL nf95_inq_varid(ncid, 'phisinit', varid) - CALL nf95_put_var(ncid, varid, phis) + CALL nf95_put_var(ncid, varid_controle, tab_cntrl) + CALL nf95_put_var(ncid, varid_rlonu, rlonu) + CALL nf95_put_var(ncid, varid_rlatu, rlatu) + CALL nf95_put_var(ncid, varid_rlonv, rlonv) + CALL nf95_put_var(ncid, varid_rlatv, rlatv) + CALL nf95_put_var(ncid, varid_xprimu, xprimu) + CALL nf95_put_var(ncid, varid_xprimv, xprimv) + CALL nf95_put_var(ncid, varid_xprimm025, xprimm025) + CALL nf95_put_var(ncid, varid_xprimp025, xprimp025) + call NF95_PUT_VAR(ncid, varid_rlatu1, rlatu1) + call NF95_PUT_VAR(ncid, varid_rlatu2, rlatu2) + CALL nf95_put_var(ncid, varid_yprimu1, yprimu1) + CALL nf95_put_var(ncid, varid_yprimu2, yprimu2) + CALL nf95_put_var(ncid, varid_ap, ap) + CALL nf95_put_var(ncid, varid_bp, bp) + CALL nf95_put_var(ncid, varid_presnivs, presnivs) + CALL nf95_put_var(ncid, varid_phisinit, phis) CALL nf95_close(ncid)