1 |
module yoecumf |
2 |
|
3 |
! From phylmd/YOECUMF.h, version 1.1.1.1 2004/05/19 12:53:07 |
4 |
|
5 |
! M. Tiedtke, ECMWF, 18th Jan. 1989 |
6 |
! Parameters for cumulus massflux scheme |
7 |
|
8 |
implicit none |
9 |
|
10 |
logical lmfpen ! penetrative convection switched on |
11 |
logical lmfscv ! shallow convection switched on |
12 |
logical lmfmid ! midlevel convection switched on |
13 |
logical lmfdd ! cumulus downdraft switched on |
14 |
logical lmfdudv ! cumulus friction switched on |
15 |
real entrpen ! entrainment rate for penetrative convection |
16 |
real entrscv ! entrainment rate for shallow convection |
17 |
real entrmid ! entrainment rate for midlevel convection |
18 |
real entrdd ! entrainment rate for cumulus downdrafts |
19 |
real cmfctop ! relative cloud massflux at level above nonbuoyanc level |
20 |
real cmfcmax ! maximum massflux value allowed for updrafts etc |
21 |
real cmfcmin ! minimum massflux value (for safety) |
22 |
real cmfdeps ! fractional massflux for downdrafts at lfs |
23 |
|
24 |
real rhcdd |
25 |
! relative saturation in downdrafts (no longer used) (formulation |
26 |
! implies saturation) |
27 |
|
28 |
real cprcon ! coefficients for determining conversion from cloud water to rain |
29 |
|
30 |
contains |
31 |
|
32 |
SUBROUTINE flxsetup |
33 |
|
34 |
! This routine defines disposable parameters for massflux scheme. |
35 |
|
36 |
!-------------------------------------------------------- |
37 |
|
38 |
ENTRPEN = 1E-4 |
39 |
ENTRSCV = 3E-4 |
40 |
ENTRMID = 1E-4 |
41 |
ENTRDD = 2E-4 |
42 |
CMFCTOP = 0.33 |
43 |
CMFCMAX = 1. |
44 |
CMFCMIN = 1E-10 |
45 |
CMFDEPS = 0.3 |
46 |
CPRCON = 2E-4 |
47 |
RHCDD = 1. |
48 |
LMFPEN = .TRUE. |
49 |
LMFSCV = .TRUE. |
50 |
LMFMID = .TRUE. |
51 |
LMFDD = .TRUE. |
52 |
LMFDUDV = .TRUE. |
53 |
|
54 |
END SUBROUTINE flxsetup |
55 |
|