--- trunk/libf/phylmd/YOECUMF.h 2008/02/27 13:16:39 3 +++ trunk/libf/phylmd/YOECUMF.f90 2008/04/18 14:45:53 10 @@ -1,42 +1,35 @@ -! -! $Header: /home/cvsroot/LMDZ4/libf/phylmd/YOECUMF.h,v 1.1.1.1 2004/05/19 12:53:07 lmdzadmin Exp $ -! -C ---------------------------------------------------------------- -C* *COMMON* *YOECUMF* - PARAMETERS FOR CUMULUS MASSFLUX SCHEME -C ---------------------------------------------------------------- -C - COMMON /YOECUMF/ - L LMFPEN,LMFSCV,LMFMID,LMFDD,LMFDUDV, - R ENTRPEN,ENTRSCV,ENTRMID,ENTRDD,CMFCTOP, - R CMFCMAX,CMFCMIN,CMFDEPS,RHCDD,CPRCON -C - LOGICAL LMFPEN,LMFSCV,LMFMID,LMFDD,LMFDUDV - REAL ENTRPEN, ENTRSCV, ENTRMID, ENTRDD - REAL CMFCTOP, CMFCMAX, CMFCMIN, CMFDEPS, RHCDD, CPRCON -C -*if (DOC,declared) <> 'UNKNOWN' -C* *COMMON* *YOECUMF* - PARAMETERS FOR CUMULUS MASSFLUX SCHEME -C -C M.TIEDTKE E. C. M. W. F. 18/1/89 -C -C NAME TYPE PURPOSE -C ---- ---- ------- -C -C LMFPEN LOGICAL TRUE IF PENETRATIVE CONVECTION IS SWITCHED ON -C LMFSCV LOGICAL TRUE IF SHALLOW CONVECTION IS SWITCHED ON -C LMFMID LOGICAL TRUE IF MIDLEVEL CONVECTION IS SWITCHED ON -C LMFDD LOGICAL TRUE IF CUMULUS DOWNDRAFT IS SWITCHED ON -C LMFDUDV LOGICAL TRUE IF CUMULUS FRICTION IS SWITCHED ON -C ENTRPEN REAL ENTRAINMENT RATE FOR PENETRATIVE CONVECTION -C ENTRSCV REAL ENTRAINMENT RATE FOR SHALLOW CONVECTION -C ENTRMID REAL ENTRAINMENT RATE FOR MIDLEVEL CONVECTION -C ENTRDD REAL ENTRAINMENT RATE FOR CUMULUS DOWNDRAFTS -C CMFCTOP REAL RELAT. CLOUD MASSFLUX AT LEVEL ABOVE NONBUOYANC -C CMFCMAX REAL MAXIMUM MASSFLUX VALUE ALLOWED FOR -C CMFCMIN REAL MINIMUM MASSFLUX VALUE (FOR SAFETY) -C CMFDEPS REAL FRACTIONAL MASSFLUX FOR DOWNDRAFTS AT LFS -C RHCDD REAL RELATIVE SATURATION IN DOWNDRAFTS -C CPRCON REAL COEFFICIENTS FOR DETERMINING CONVERSION -C FROM CLOUD WATER TO RAIN -*ifend -C ---------------------------------------------------------------- +module yoecumf + + ! From phylmd/YOECUMF.h,v 1.1.1.1 2004/05/19 12:53:07 + + ! PARAMETERS FOR CUMULUS MASSFLUX SCHEME + + implicit none + + LOGICAL LMFPEN,LMFSCV,LMFMID,LMFDD,LMFDUDV + REAL ENTRPEN, ENTRSCV, ENTRMID, ENTRDD + REAL CMFCTOP, CMFCMAX, CMFCMIN, CMFDEPS, RHCDD, CPRCON + + ! M.TIEDTKE E. C. M. W. F. 18/1/89 + ! + ! NAME TYPE PURPOSE + ! ---- ---- ------- + ! + ! LMFPEN LOGICAL TRUE IF PENETRATIVE CONVECTION IS SWITCHED ON + ! LMFSCV LOGICAL TRUE IF SHALLOW CONVECTION IS SWITCHED ON + ! LMFMID LOGICAL TRUE IF MIDLEVEL CONVECTION IS SWITCHED ON + ! LMFDD LOGICAL TRUE IF CUMULUS DOWNDRAFT IS SWITCHED ON + ! LMFDUDV LOGICAL TRUE IF CUMULUS FRICTION IS SWITCHED ON + ! ENTRPEN REAL ENTRAINMENT RATE FOR PENETRATIVE CONVECTION + ! ENTRSCV REAL ENTRAINMENT RATE FOR SHALLOW CONVECTION + ! ENTRMID REAL ENTRAINMENT RATE FOR MIDLEVEL CONVECTION + ! ENTRDD REAL ENTRAINMENT RATE FOR CUMULUS DOWNDRAFTS + ! CMFCTOP REAL RELAT. CLOUD MASSFLUX AT LEVEL ABOVE NONBUOYANC + ! CMFCMAX REAL MAXIMUM MASSFLUX VALUE ALLOWED FOR + ! CMFCMIN REAL MINIMUM MASSFLUX VALUE (FOR SAFETY) + ! CMFDEPS REAL FRACTIONAL MASSFLUX FOR DOWNDRAFTS AT LFS + ! RHCDD REAL RELATIVE SATURATION IN DOWNDRAFTS + ! CPRCON REAL COEFFICIENTS FOR DETERMINING CONVERSION + ! FROM CLOUD WATER TO RAIN + +end module yoecumf