/[lmdze]/trunk/dyn3d/advtrac.f
ViewVC logotype

Diff of /trunk/dyn3d/advtrac.f

Parent Directory Parent Directory | Revision Log Revision Log | View Patch Patch

trunk/libf/dyn3d/advtrac.f90 revision 31 by guez, Thu Apr 1 14:59:19 2010 UTC trunk/dyn3d/advtrac.f revision 104 by guez, Thu Sep 4 10:05:52 2014 UTC
# Line 1  Line 1 
1  SUBROUTINE advtrac(pbaru, pbarv, p, masse, q, iapptrac, teta, pk)  module advtrac_m
2    
3    ! From dyn3d/advtrac.F, version 1.4 2005/04/13 08:58:34    IMPLICIT NONE
   ! Author: F. Hourdin  
4    
5    USE dimens_m, ONLY : iim, jjm, llm, nqmx  contains
   USE paramet_m, ONLY : iip1, iip2, ijmllm, ijp1llm, ip1jm, ip1jmp1, jjp1, &  
        llmp1  
   USE comconst, ONLY : dtvr  
   USE conf_gcm_m, ONLY : iapp_tracvl  
   USE iniadvtrac_m, ONLY : iadv  
6    
7    IMPLICIT NONE    SUBROUTINE advtrac(pbaru, pbarv, p, masse, q, iapptrac, teta, pk)
8    
9    !     Arguments      ! From dyn3d/advtrac.F, version 1.4 2005/04/13 08:58:34
10        ! Author: F. Hourdin
11    
12    REAL massebx(ip1jmp1, llm), masseby(ip1jm, llm)      USE comconst, ONLY : dtvr
13        USE conf_gcm_m, ONLY : iapp_tracvl
14        USE dimens_m, ONLY : iim, jjm, llm, nqmx
15        USE iniadvtrac_m, ONLY : iadv
16        use massbar_m, only: massbar
17        USE paramet_m, ONLY : iip1, iip2, ijmllm, ijp1llm, ip1jm, ip1jmp1, jjp1, &
18             llmp1
19    
20        REAL, intent(in):: pbaru(ip1jmp1, llm), pbarv(ip1jm, llm)
21        REAL, intent(in):: p(ip1jmp1, llmp1)
22        real, intent(in):: masse(ip1jmp1, llm)
23        REAL, intent(inout):: q(ip1jmp1, llm, nqmx)
24        INTEGER, intent(out):: iapptrac
25        real, intent(in):: teta(ip1jmp1, llm)
26        REAL, intent(in):: pk(ip1jmp1, llm)
27    
28        ! Variables locales
29    
30        REAL massebx(ip1jmp1, llm), masseby(ip1jm, llm)
31        REAL, save:: pbaruc(ip1jmp1, llm), pbarvc(ip1jm, llm)
32        REAL, save:: massem(ip1jmp1, llm)
33        real zdp(ip1jmp1)
34        REAL pbarug(ip1jmp1, llm), pbarvg(ip1jm, llm), wg(ip1jmp1, llm)
35    
36        INTEGER:: iadvtr = 0
37        INTEGER ij, l, iq
38        REAL zdpmin, zdpmax
39        EXTERNAL minmax
40    
41        ! Rajouts pour PPM
42    
43        INTEGER indice, n
44        ! Pas de temps adaptatif pour que CFL < 1
45        REAL dtbon
46        REAL cflmaxz ! CFL maximum
47        real aaa, bbb
48        REAL psppm(iim, jjp1) ! pression au sol
49        REAL unatppm(iim, jjp1, llm), vnatppm(iim, jjp1, llm)
50        REAL qppm(iim*jjp1, llm, nqmx)
51        REAL fluxwppm(iim, jjp1, llm)
52        REAL apppm(llmp1), bpppm(llmp1)
53        LOGICAL:: dum = .TRUE., fill = .TRUE.
54    
55        !-----------------------------------------------------------
56    
57        IF (iadvtr==0) THEN
58           CALL initial0(ijp1llm, pbaruc)
59           CALL initial0(ijmllm, pbarvc)
60        END IF
61    
62        ! accumulation des flux de masse horizontaux
63        DO l = 1, llm
64           DO ij = 1, ip1jmp1
65              pbaruc(ij, l) = pbaruc(ij, l) + pbaru(ij, l)
66           END DO
67           DO ij = 1, ip1jm
68              pbarvc(ij, l) = pbarvc(ij, l) + pbarv(ij, l)
69           END DO
70        END DO
71    
72        ! selection de la masse instantannee des mailles avant le transport.
73        IF (iadvtr==0) massem = masse
74    
75        iadvtr = iadvtr + 1
76        iapptrac = iadvtr
77    
78        ! Test pour savoir si on advecte a ce pas de temps
79        IF (iadvtr == iapp_tracvl) THEN
80           ! traitement des flux de masse avant advection.
81           ! 1. calcul de w
82           ! 2. groupement des mailles pres du pole.
83    
84           CALL groupe(massem, pbaruc, pbarvc, pbarug, pbarvg, wg)
85    
86           ! test sur l'eventuelle creation de valeurs negatives de la masse
87           DO l = 1, llm - 1
88              DO ij = iip2 + 1, ip1jm
89                 zdp(ij) = pbarug(ij-1, l) - pbarug(ij, l) - pbarvg(ij-iip1, l) + &
90                      pbarvg(ij, l) + wg(ij, l+1) - wg(ij, l)
91              END DO
92              CALL scopy(jjm-1, zdp(iip1+iip1), iip1, zdp(iip2), iip1)
93              DO ij = iip2, ip1jm
94                 zdp(ij) = zdp(ij)*dtvr/massem(ij, l)
95              END DO
96    
97              CALL minmax(ip1jm-iip1, zdp(iip2), zdpmin, zdpmax)
98    
99              IF (max(abs(zdpmin), abs(zdpmax))>0.5) THEN
100                 PRINT *, 'WARNING DP/P l=', l, ' MIN:', zdpmin, ' MAX:', zdpmax
101              END IF
102           END DO
103    
104           ! Advection proprement dite
105    
106           ! Calcul des moyennes basées sur la masse
107           CALL massbar(massem, massebx, masseby)
108    
109           ! Appel des sous programmes d'advection
110    
111           DO iq = 1, nqmx
112              IF (iadv(iq)==0) CYCLE
113    
114              ! Schema de Van Leer I MUSCL
115    
116              IF (iadv(iq)==10) THEN
117                 CALL vlsplt(q(:, :, iq), 2., massem, wg, pbarug, pbarvg, dtvr)
118                 ! Schema "pseudo amont" + test sur humidite specifique
119                 ! pour la vapeur d'eau. F. Codron
120              ELSE IF (iadv(iq)==14) THEN
121                 CALL vlspltqs(q(1, 1, 1), 2., massem, wg, pbarug, pbarvg, dtvr, &
122                      p, pk, teta)
123                 ! Schema de Frederic Hourdin
124              ELSE IF (iadv(iq)==12) THEN
125                 ! Pas de temps adaptatif
126                 CALL adaptdt(dtbon, n, pbarug, massem)
127                 IF (n>1) THEN
128                    WRITE (*, *) 'WARNING horizontal dt=', dtbon, 'dtvr=', dtvr, &
129                         'n=', n
130                 END IF
131                 DO indice = 1, n
132                    CALL advn(q(1, 1, iq), massem, wg, pbarug, pbarvg, dtbon, 1)
133                 END DO
134              ELSE IF (iadv(iq)==13) THEN
135                 ! Pas de temps adaptatif
136                 CALL adaptdt(dtbon, n, pbarug, massem)
137                 IF (n>1) THEN
138                    WRITE (*, *) 'WARNING horizontal dt=', dtbon, 'dtvr=', dtvr, &
139                         'n=', n
140                 END IF
141                 DO indice = 1, n
142                    CALL advn(q(1, 1, iq), massem, wg, pbarug, pbarvg, dtbon, 2)
143                 END DO
144                 ! Schema de pente SLOPES
145              ELSE IF (iadv(iq)==20) THEN
146                 CALL pentes_ini(q(1, 1, iq), wg, massem, pbarug, pbarvg, 0)
147                 ! Schema de Prather
148              ELSE IF (iadv(iq)==30) THEN
149                 ! Pas de temps adaptatif
150                 CALL adaptdt(dtbon, n, pbarug, massem)
151                 IF (n>1) THEN
152                    WRITE (*, *) 'WARNING horizontal dt=', dtbon, 'dtvr=', dtvr, &
153                         'n=', n
154                 END IF
155                 CALL prather(q(1, 1, iq), wg, massem, pbarug, pbarvg, n, dtbon)
156                 ! Schemas PPM Lin et Rood
157              ELSE IF (iadv(iq)==11 .OR. (iadv(iq)>=16 .AND. iadv(iq)<=18)) THEN
158                 ! Test sur le flux horizontal
159                 ! Pas de temps adaptatif
160                 CALL adaptdt(dtbon, n, pbarug, massem)
161                 IF (n>1) THEN
162                    WRITE (*, *) 'WARNING horizontal dt=', dtbon, 'dtvr=', dtvr, &
163                         'n=', n
164                 END IF
165                 ! Test sur le flux vertical
166                 cflmaxz = 0.
167                 DO l = 2, llm
168                    DO ij = iip2, ip1jm
169                       aaa = wg(ij, l)*dtvr/massem(ij, l)
170                       cflmaxz = max(cflmaxz, aaa)
171                       bbb = -wg(ij, l)*dtvr/massem(ij, l-1)
172                       cflmaxz = max(cflmaxz, bbb)
173                    END DO
174                 END DO
175                 IF (cflmaxz>=1) THEN
176                    WRITE (*, *) 'WARNING vertical', 'CFLmaxz=', cflmaxz
177                 END IF
178    
179                 ! Ss-prg interface LMDZ.4->PPM3d
180                 CALL interpre(q(1, 1, iq), qppm(1, 1, iq), wg, fluxwppm, massem, &
181                      apppm, bpppm, massebx, masseby, pbarug, pbarvg, unatppm, &
182                      vnatppm, psppm)
183    
184                 DO indice = 1, n
185                    ! VL (version PPM) horiz. et PPM vert.
186                    IF (iadv(iq)==11) THEN
187                       ! Ss-prg PPM3d de Lin
188                       CALL ppm3d(1, qppm(1, 1, iq), psppm, psppm, unatppm, &
189                            vnatppm, fluxwppm, dtbon, 2, 2, 2, 1, iim, jjp1, 2, &
190                            llm, apppm, bpppm, 0.01, 6400000, fill, dum, 220.)
191                       ! Monotonic PPM
192                    ELSE IF (iadv(iq)==16) THEN
193                       ! Ss-prg PPM3d de Lin
194                       CALL ppm3d(1, qppm(1, 1, iq), psppm, psppm, unatppm, &
195                            vnatppm, fluxwppm, dtbon, 3, 3, 3, 1, iim, jjp1, 2, &
196                            llm, apppm, bpppm, 0.01, 6400000, fill, dum, 220.)
197                       ! Semi Monotonic PPM
198                    ELSE IF (iadv(iq)==17) THEN
199                       ! Ss-prg PPM3d de Lin
200                       CALL ppm3d(1, qppm(1, 1, iq), psppm, psppm, unatppm, &
201                            vnatppm, fluxwppm, dtbon, 4, 4, 4, 1, iim, jjp1, 2, &
202                            llm, apppm, bpppm, 0.01, 6400000, fill, dum, 220.)
203                       ! Positive Definite PPM
204                    ELSE IF (iadv(iq)==18) THEN
205                       ! Ss-prg PPM3d de Lin
206                       CALL ppm3d(1, qppm(1, 1, iq), psppm, psppm, unatppm, &
207                            vnatppm, fluxwppm, dtbon, 5, 5, 5, 1, iim, jjp1, 2, &
208                            llm, apppm, bpppm, 0.01, 6400000, fill, dum, 220.)
209                    END IF
210                 END DO
211    
212                 ! Ss-prg interface PPM3d-LMDZ.4
213                 CALL interpost(q(1, 1, iq), qppm(1, 1, iq))
214              END IF
215           END DO
216    
217           ! on reinitialise a zero les flux de masse cumules
218           iadvtr = 0
219        END IF
220    
221    INTEGER iapptrac    END SUBROUTINE advtrac
   REAL pbaru(ip1jmp1, llm), pbarv(ip1jm, llm)  
   REAL q(ip1jmp1, llm, nqmx), masse(ip1jmp1, llm)  
   REAL, intent(in):: p(ip1jmp1, llmp1)  
   real teta(ip1jmp1, llm)  
   REAL pk(ip1jmp1, llm)  
   
   !     Variables locales  
   
   REAL pbaruc(ip1jmp1, llm), pbarvc(ip1jm, llm)  
   REAL massem(ip1jmp1, llm), zdp(ip1jmp1)  
   REAL pbarug(ip1jmp1, llm), pbarvg(ip1jm, llm), wg(ip1jmp1, llm)  
   REAL cpuadv(nqmx)  
   COMMON /cpuadv/cpuadv  
   
   INTEGER iadvtr  
   INTEGER ij, l, iq  
   REAL zdpmin, zdpmax  
   EXTERNAL minmax  
   SAVE iadvtr, massem, pbaruc, pbarvc  
   DATA iadvtr/0/  
   
   !     Rajouts pour PPM  
   
   INTEGER indice, n  
   ! Pas de temps adaptatif pour que CFL<1                  
   REAL dtbon  
   REAL cflmaxz ! CFL maximum  
   real aaa, bbb  
   REAL psppm(iim, jjp1) ! pression  au sol                            
   REAL unatppm(iim, jjp1, llm), vnatppm(iim, jjp1, llm)  
   REAL qppm(iim*jjp1, llm, nqmx)  
   REAL fluxwppm(iim, jjp1, llm)  
   REAL apppm(llmp1), bpppm(llmp1)  
   LOGICAL dum, fill  
   DATA fill/ .TRUE./  
   DATA dum/ .TRUE./  
   
   !-----------------------------------------------------------  
   
   IF (iadvtr==0) THEN  
      CALL initial0(ijp1llm, pbaruc)  
      CALL initial0(ijmllm, pbarvc)  
   END IF  
   
   !   accumulation des flux de masse horizontaux  
   DO l = 1, llm  
      DO ij = 1, ip1jmp1  
         pbaruc(ij, l) = pbaruc(ij, l) + pbaru(ij, l)  
      END DO  
      DO ij = 1, ip1jm  
         pbarvc(ij, l) = pbarvc(ij, l) + pbarv(ij, l)  
      END DO  
   END DO  
   
   !   selection de la masse instantannee des mailles avant le transport.  
   IF (iadvtr==0) THEN  
      CALL scopy(ip1jmp1*llm, masse, 1, massem, 1)  
   END IF  
   
   iadvtr = iadvtr + 1  
   iapptrac = iadvtr  
   
   !   Test pour savoir si on advecte a ce pas de temps  
   IF (iadvtr==iapp_tracvl) THEN  
      !   traitement des flux de masse avant advection.  
      !     1. calcul de w  
      !     2. groupement des mailles pres du pole.  
   
      CALL groupe(massem, pbaruc, pbarvc, pbarug, pbarvg, wg)  
   
      !  test sur l'eventuelle creation de valeurs negatives de la masse  
      DO l = 1, llm - 1  
         DO ij = iip2 + 1, ip1jm  
            zdp(ij) = pbarug(ij-1, l) - pbarug(ij, l) - pbarvg(ij-iip1, l) + &  
                 pbarvg(ij, l) + wg(ij, l+1) - wg(ij, l)  
         END DO  
         CALL scopy(jjm-1, zdp(iip1+iip1), iip1, zdp(iip2), iip1)  
         DO ij = iip2, ip1jm  
            zdp(ij) = zdp(ij)*dtvr/massem(ij, l)  
         END DO  
   
         CALL minmax(ip1jm-iip1, zdp(iip2), zdpmin, zdpmax)  
   
         IF (max(abs(zdpmin), abs(zdpmax))>0.5) THEN  
            PRINT *, 'WARNING DP/P l=', l, '  MIN:', zdpmin, '   MAX:', zdpmax  
         END IF  
      END DO  
   
      !   Advection proprement dite  
   
      !        Calcul des moyennes basées sur la masse  
      CALL massbar(massem, massebx, masseby)  
   
      !     Appel des sous programmes d'advection  
   
      DO iq = 1, nqmx  
         IF (iadv(iq)==0) CYCLE  
   
         !   Schema de Van Leer I MUSCL  
   
         IF (iadv(iq)==10) THEN  
            CALL vlsplt(q(1, 1, iq), 2., massem, wg, pbarug, pbarvg, dtvr)  
            !   Schema "pseudo amont" + test sur humidite specifique  
            !    pour la vapeur d'eau. F. Codron  
         ELSE IF (iadv(iq)==14) THEN  
            CALL vlspltqs(q(1, 1, 1), 2., massem, wg, pbarug, pbarvg, dtvr, p, &  
                 pk, teta)  
            !   Schema de Frederic Hourdin  
         ELSE IF (iadv(iq)==12) THEN  
            !            Pas de temps adaptatif  
            CALL adaptdt(iadv(iq), dtbon, n, pbarug, massem)  
            IF (n>1) THEN  
               WRITE (*, *) 'WARNING horizontal dt=', dtbon, 'dtvr=', dtvr, &  
                    'n=', n  
            END IF  
            DO indice = 1, n  
               CALL advn(q(1, 1, iq), massem, wg, pbarug, pbarvg, dtbon, 1)  
            END DO  
         ELSE IF (iadv(iq)==13) THEN  
            !            Pas de temps adaptatif  
            CALL adaptdt(iadv(iq), dtbon, n, pbarug, massem)  
            IF (n>1) THEN  
               WRITE (*, *) 'WARNING horizontal dt=', dtbon, 'dtvr=', dtvr, &  
                    'n=', n  
            END IF  
            DO indice = 1, n  
               CALL advn(q(1, 1, iq), massem, wg, pbarug, pbarvg, dtbon, 2)  
            END DO  
            !   Schema de pente SLOPES  
         ELSE IF (iadv(iq)==20) THEN  
            CALL pentes_ini(q(1, 1, iq), wg, massem, pbarug, pbarvg, 0)  
            !   Schema de Prather  
         ELSE IF (iadv(iq)==30) THEN  
            !            Pas de temps adaptatif  
            CALL adaptdt(iadv(iq), dtbon, n, pbarug, massem)  
            IF (n>1) THEN  
               WRITE (*, *) 'WARNING horizontal dt=', dtbon, 'dtvr=', dtvr, &  
                    'n=', n  
            END IF  
            CALL prather(q(1, 1, iq), wg, massem, pbarug, pbarvg, n, dtbon)  
            !   Schemas PPM Lin et Rood  
         ELSE IF (iadv(iq)==11 .OR. (iadv(iq)>=16 .AND. iadv(iq)<=18)) THEN  
            !        Test sur le flux horizontal  
            !        Pas de temps adaptatif  
            CALL adaptdt(iadv(iq), dtbon, n, pbarug, massem)  
            IF (n>1) THEN  
               WRITE (*, *) 'WARNING horizontal dt=', dtbon, 'dtvr=', dtvr, &  
                    'n=', n  
            END IF  
            !        Test sur le flux vertical  
            cflmaxz = 0.  
            DO l = 2, llm  
               DO ij = iip2, ip1jm  
                  aaa = wg(ij, l)*dtvr/massem(ij, l)  
                  cflmaxz = max(cflmaxz, aaa)  
                  bbb = -wg(ij, l)*dtvr/massem(ij, l-1)  
                  cflmaxz = max(cflmaxz, bbb)  
               END DO  
            END DO  
            IF (cflmaxz>=1) THEN  
               WRITE (*, *) 'WARNING vertical', 'CFLmaxz=', cflmaxz  
            END IF  
   
            !        Ss-prg interface LMDZ.4->PPM3d  
            CALL interpre(q(1, 1, iq), qppm(1, 1, iq), wg, fluxwppm, massem, &  
                 apppm, bpppm, massebx, masseby, pbarug, pbarvg, unatppm, &  
                 vnatppm, psppm)  
   
            DO indice = 1, n  
               !                         VL (version PPM) horiz. et PPM vert.  
               IF (iadv(iq)==11) THEN  
                  !                  Ss-prg PPM3d de Lin  
                  CALL ppm3d(1, qppm(1, 1, iq), psppm, psppm, unatppm, &  
                       vnatppm, fluxwppm, dtbon, 2, 2, 2, 1, iim, jjp1, 2, &  
                       llm, apppm, bpppm, 0.01, 6400000, fill, dum, 220.)  
                  !                           Monotonic PPM  
               ELSE IF (iadv(iq)==16) THEN  
                  !                  Ss-prg PPM3d de Lin  
                  CALL ppm3d(1, qppm(1, 1, iq), psppm, psppm, unatppm, &  
                       vnatppm, fluxwppm, dtbon, 3, 3, 3, 1, iim, jjp1, 2, &  
                       llm, apppm, bpppm, 0.01, 6400000, fill, dum, 220.)  
                  !                           Semi Monotonic PPM  
               ELSE IF (iadv(iq)==17) THEN  
                  !                  Ss-prg PPM3d de Lin  
                  CALL ppm3d(1, qppm(1, 1, iq), psppm, psppm, unatppm, &  
                       vnatppm, fluxwppm, dtbon, 4, 4, 4, 1, iim, jjp1, 2, &  
                       llm, apppm, bpppm, 0.01, 6400000, fill, dum, 220.)  
                  !                         Positive Definite PPM  
               ELSE IF (iadv(iq)==18) THEN  
                  !                  Ss-prg PPM3d de Lin  
                  CALL ppm3d(1, qppm(1, 1, iq), psppm, psppm, unatppm, &  
                       vnatppm, fluxwppm, dtbon, 5, 5, 5, 1, iim, jjp1, 2, &  
                       llm, apppm, bpppm, 0.01, 6400000, fill, dum, 220.)  
               END IF  
            END DO  
   
            !               Ss-prg interface PPM3d-LMDZ.4  
            CALL interpost(q(1, 1, iq), qppm(1, 1, iq))  
         END IF  
      END DO  
   
      !   on reinitialise a zero les flux de masse cumules  
      iadvtr = 0  
   END IF  
222    
223  END SUBROUTINE advtrac  end module advtrac_m

Legend:
Removed from v.31  
changed lines
  Added in v.104

  ViewVC Help
Powered by ViewVC 1.1.21