/[lmdze]/trunk/dyn3d/conf_gcm.f
ViewVC logotype

Diff of /trunk/dyn3d/conf_gcm.f

Parent Directory Parent Directory | Revision Log Revision Log | View Patch Patch

revision 3 by guez, Wed Feb 27 13:16:39 2008 UTC revision 39 by guez, Tue Jan 25 15:11:05 2011 UTC
# Line 1  Line 1 
1  module conf_gcm_m  module conf_gcm_m
2    
   ! This module is clean: no C preprocessor directive, no include line  
   
3    IMPLICIT NONE    IMPLICIT NONE
4    
5    INTEGER:: nday= 10    INTEGER:: nday = 10 ! nombre de jours d'intégration
6    ! Nombre de jours d'integration    integer:: day_step = 240 ! nombre de pas par jour, multiple de iperiod
   ! On pourait aussi permettre des mois ou des annees !  
   
   integer:: day_step= 240 ! nombre de pas par jour, multiple de iperiod  
7    
8    integer:: iperiod= 5    integer:: iperiod = 5
9    ! periode pour le pas Matsuno (en pas de temps)    ! periode pour le pas Matsuno (en pas de temps)
10    
11    integer:: iapp_tracvl= 5    integer:: iapp_tracvl = 5
12    ! Should normally be equal to "iperiod"    ! Should normally be equal to "iperiod"
13    ! frequence du groupement des flux (en pas de temps)    ! frequence du groupement des flux (en pas de temps)
14    
15    integer:: iconser= 240    integer:: iconser = 240
16    ! periode de sortie des variables de controle    ! number of time steps between output of control variables
   ! (En pas de temps)  
   
   integer:: iecri= 1 ! période d'écriture du fichier "dyn_hist.nc" (en jours)  
   
   integer:: idissip= 10 ! periode de la dissipation (en pas)  
17    
18    integer:: iphysiq= 5    integer:: iecri = 1 ! time interval between outputs to "dyn_hist.nc" (in days)
19    ! Help = Periode de la physique en pas de temps de la dynamique.    integer:: iphysiq = 5 ! période de la physique en pas de temps de la dynamique
20    
21    integer:: dayref = 1 ! jour de l'année de l'état initial    integer:: dayref = 1 ! jour de l'année de l'état initial
22    ! (= 350 si 20 décembre par exemple)    ! (= 350 si 20 décembre par exemple)
23    
24    integer:: anneeref = 1998 ! Annee de l'etat initial (avec 4 chiffres)    integer:: anneeref = 1998 ! Annee de l'etat initial (avec 4 chiffres)
25    
26    integer:: raz_date = 0 ! Remise a zero de la date initiale    logical:: raz_date = .false.
27    ! 0 pas de remise a zero, on garde la date du fichier restart    ! (remise a zero de la date initiale, prise en compte de la date de
28    ! 1 prise en compte de la date de gcm.def avec remise a zero    ! gcm.def avec remise a zero des compteurs de pas de temps)
29    ! des compteurs de pas de temps    ! (pas de remise a zero: on garde la date du fichier restart)
30    
31    REAL:: periodav= 1.    REAL:: periodav = 1. ! time interval between outputs to "histmoy" (in days)
   ! periode de stockage fichier histmoy (en jour)  
32    
33    logical, save:: offline    logical:: offline = .FALSE.
34      ! permet de mettre en route la nouvelle parametrisation de l'eau liquide
35    
36  contains  contains
37    
38    SUBROUTINE conf_gcm(clesphy0)    SUBROUTINE conf_gcm
39    
40      ! Auteurs : L. Fairhead, P. Le Van      ! Auteurs : L. Fairhead, P. Le Van
41      ! Version du 29/04/97      ! Version du 29/04/97
42    
     ! Nouveaux paramètres nitergdiv, nitergrot, niterh, tetagdiv, tetagrot,  
     ! tetatemp ajoutés pour la dissipation.  
   
     ! Autre paramètre ajouté en fin de liste de tapedef : fxyhypb  
     ! Si fxyhypb = .TRUE., choix de la fonction à dérivée tangente  
     ! hyperbolique  
     ! Sinon, choix de fxynew, à dérivée sinusoïdale  
   
43      ! On ne compare pas les valeurs des paramètres du zoom, grossismx,      ! On ne compare pas les valeurs des paramètres du zoom, grossismx,
44      ! grossismy, clon, clat, fxyhypb lues sur le fichier start avec      ! grossismy, clon, clat, fxyhypb lues sur le fichier start avec
45      ! celles passées par run.def, au début du gcm.      ! celles passées par run.def, au début du gcm.
46      ! Ces paramètres définissent entre autres la grille et doivent être      ! Ces paramètres définissent entre autres la grille et doivent être
47      ! cohérents, sinon il y aura divergence du gcm.      ! cohérents, sinon il y aura divergence du gcm.
48    
49      use IOIPSL, only: getin      use abort_gcm_m, only: abort_gcm
     use dimens_m  
     use paramet_m  
50      use comdissnew, only: read_comdissnew      use comdissnew, only: read_comdissnew
51      use logic, only: iflag_phys, fxyhypb, ysinus, purmats, ok_guide      use logic, only: read_logic
52      use serre, only: clon, clat, grossismx, grossismy, alphax, alphay, &      use serre, only: clon, clat, grossismx, grossismy, alphax, alphay, &
53           dzoomx, dzoomy, taux, tauy           dzoomx, dzoomy, taux, tauy
54      use clesphys, only: ok_limitvrai, ok_orolf, iflag_con, nbapp_rad, &      use iniprint, only: read_iniprint
          ok_orodr, cycle_diurne, new_oliq, soil_model  
     use iniprint, only: lunout, read_iniprint  
   
     INTEGER, PARAMETER:: longcles = 20  
   
     REAL, intent(out), optional:: clesphy0(longcles)  
55    
56      namelist /conf_gcm_nml/dayref, anneeref, raz_date, nday, day_step, &      namelist /conf_gcm_nml/dayref, anneeref, raz_date, nday, day_step, &
57           iperiod, iapp_tracvl, iconser, iecri, periodav, idissip, purmats, &           iperiod, iapp_tracvl, iconser, iecri, periodav, &
58           ok_guide, iflag_phys, iphysiq, cycle_diurne, soil_model, new_oliq, &           iphysiq, clon, clat, grossismx, grossismy, dzoomx, dzoomy, taux, &
59           ok_orodr, ok_orolf, ok_limitvrai, nbapp_rad, iflag_con, clon, clat, &           tauy, offline
          grossismx, grossismy, dzoomx, dzoomy, taux, tauy  
60    
61      !------------------------------------      !------------------------------------
62    
63      print *, "Call sequence information: conf_gcm"      print *, "Call sequence information: conf_gcm"
64    
65      call read_iniprint      call read_iniprint
66        call read_logic
67        call read_comdissnew
68    
69      print *, "Enter namelist 'conf_gcm_nml'."      print *, "Enter namelist 'conf_gcm_nml'."
70      read(unit=*, nml=conf_gcm_nml)      read(unit=*, nml=conf_gcm_nml)
71      write(unit=*, nml=conf_gcm_nml)      write(unit=*, nml=conf_gcm_nml)
72    
73      call read_comdissnew      IF (MOD(day_step, iperiod) /= 0) call abort_gcm(modname = "gcm", &
74             message = &
75      IF (lunout /= 5 .and. lunout /= 6) THEN           'Il faut choisir un nombre de pas par jour multiple de "iperiod".', &
76         OPEN(lunout, FILE='lmdz.out')           ierr = 1)
77      ENDIF  
78        IF (MOD(day_step,iphysiq)/= 0) call abort_gcm(modname = "gcm", message = &
79      if (present(clesphy0)) then           'Il faut choisir un nombre de pas par jour multiple de "iphysiq".', &
80         clesphy0(:) = 0.           ierr = 1)
        clesphy0(1) = REAL(iflag_con)  
        clesphy0(2) = REAL(nbapp_rad)  
   
        IF (cycle_diurne) clesphy0(3) = 1.  
        IF (soil_model) clesphy0(4) = 1.  
        IF (new_oliq) clesphy0(5) = 1.  
        IF (ok_orodr) clesphy0(6) = 1.  
        IF (ok_orolf) clesphy0(7) = 1.  
        IF (ok_limitvrai) clesphy0(8) = 1.  
     end if  
81    
82      IF (grossismx < 1.) THEN      IF (grossismx < 1.) THEN
83         PRINT *, 'Error: grossismx < 1'         PRINT *, 'Error: grossismx < 1'
# Line 128  contains Line 94  contains
94      PRINT *, 'alphax = ', alphax      PRINT *, 'alphax = ', alphax
95      PRINT *, 'alphay = ', alphay      PRINT *, 'alphay = ', alphay
96    
     ! Key = fxyhypb  
     ! Desc = Fonction hyperbolique  
     ! Def = y  
     ! Help = Fonction f(y) hyperbolique si = .true.  
     ! sinon sinusoidale  
     fxyhypb = .TRUE.  
     CALL getin('fxyhypb', fxyhypb)  
   
     ! Key = ysinus  
     ! IF = !fxyhypb  
     ! Desc = Fonction en Sinus  
     ! Def = y  
     ! Help = Fonction f(y) avec y = Sin(latit.) si = .true.  
     ! sinon y = latit.  
     ysinus = .TRUE.  
     CALL getin('ysinus', ysinus)  
   
     ! Key = offline  
     ! Desc = Nouvelle eau liquide  
     ! Def = n  
     ! Help = Permet de mettre en route la  
     ! nouvelle parametrisation de l'eau liquide  
     offline = .FALSE.  
     CALL getin('offline', offline)  
     write(lunout, *)' offline = ', offline  
   
97    END SUBROUTINE conf_gcm    END SUBROUTINE conf_gcm
98    
99  end module conf_gcm_m  end module conf_gcm_m

Legend:
Removed from v.3  
changed lines
  Added in v.39

  ViewVC Help