/[lmdze]/trunk/dyn3d/conf_gcm.f
ViewVC logotype

Diff of /trunk/dyn3d/conf_gcm.f

Parent Directory Parent Directory | Revision Log Revision Log | View Patch Patch

trunk/libf/dyn3d/conf_gcm.f90 revision 40 by guez, Tue Feb 22 13:49:36 2011 UTC trunk/dyn3d/conf_gcm.f revision 115 by guez, Fri Sep 19 17:36:20 2014 UTC
# Line 26  module conf_gcm_m Line 26  module conf_gcm_m
26    integer:: anneeref = 1998 ! Annee de l'etat initial (avec 4 chiffres)    integer:: anneeref = 1998 ! Annee de l'etat initial (avec 4 chiffres)
27    
28    logical:: raz_date = .false.    logical:: raz_date = .false.
29    ! (remise a zero de la date initiale, prise en compte de la date de    ! prise en compte de la date initiale de la namelist et remise à
30    ! gcm.def avec remise a zero des compteurs de pas de temps)    ! zéro des compteurs de pas de temps (sinon on garde la date du
31    ! (pas de remise a zero: on garde la date du fichier restart)    ! fichier restart)
32    
33    REAL:: periodav = 1. ! time interval between outputs to "histmoy" (in days)    integer:: periodav = 1
34      ! time interval between outputs in the dynamical part, in days
35    
36    logical:: offline = .FALSE.    logical:: offline = .FALSE.
37    ! permet de mettre en route la nouvelle parametrisation de l'eau liquide    ! permet de mettre en route la nouvelle parametrisation de l'eau liquide
38    
39      integer:: prt_level = 0 ! niveau d'impression souhaité (0 = minimum)
40    
41      LOGICAL:: purmats= .FALSE.
42      ! Help = Choix du schema d'integration temporel.
43      ! y = pure Matsuno sinon c'est du Matsuno-leapfrog
44    
45      INTEGER:: iflag_phys = 1
46      ! contrôle l'appel à la physique :
47      ! 0 : pas de physique
48      ! 1 : physique normale (appel à phylmd, phymars...) (default)
49      ! 2 : rappel Newtonien pour la température + friction au sol
50    
51  contains  contains
52    
53    SUBROUTINE conf_gcm    SUBROUTINE conf_gcm
# Line 42  contains Line 55  contains
55      ! Auteurs : L. Fairhead, P. Le Van      ! Auteurs : L. Fairhead, P. Le Van
56      ! Version du 29/04/97      ! Version du 29/04/97
57    
58      ! On ne compare pas les valeurs des paramètres du zoom, grossismx,      ! On ne compare pas les paramètres du zoom (grossismx, grossismy,
59      ! grossismy, clon, clat, fxyhypb lues sur le fichier start avec      ! clon, clat) lus sur le fichier start avec ceux lus dans
60      ! celles passées par run.def, au début du gcm.      ! une namelist, au début de gcm. Ces paramètres définissent entre
61      ! Ces paramètres définissent entre autres la grille et doivent être      ! autres la grille et doivent être identiques, sinon il y aura
62      ! cohérents, sinon il y aura divergence du gcm.      ! divergence du gcm.
63    
64      use abort_gcm_m, only: abort_gcm      use abort_gcm_m, only: abort_gcm
65      use comdissnew, only: read_comdissnew      use comdissnew, only: read_comdissnew
66      use logic, only: read_logic      use unit_nml_m, only: unit_nml
     use serre, only: clon, clat, grossismx, grossismy, alphax, alphay, &  
          dzoomx, dzoomy, taux, tauy  
     use iniprint, only: read_iniprint  
67    
68      namelist /conf_gcm_nml/dayref, anneeref, raz_date, nday, day_step, &      namelist /conf_gcm_nml/dayref, anneeref, raz_date, nday, day_step, &
69           iperiod, iapp_tracvl, iconser, iecri, periodav, &           iperiod, iapp_tracvl, iconser, iecri, periodav, iphysiq, offline
70           iphysiq, clon, clat, grossismx, grossismy, dzoomx, dzoomy, taux, &  
71           tauy, offline      namelist /iniprint_nml/prt_level
72    
73        namelist /logic_nml/ purmats, iflag_phys
74    
75      !------------------------------------      !------------------------------------
76    
77      print *, "Call sequence information: conf_gcm"      print *, "Call sequence information: conf_gcm"
78    
79      call read_iniprint      print *, "Enter namelist 'iniprint_nml'."
80      call read_logic      read(unit=*, nml=iniprint_nml)
81        write(unit_nml, nml=iniprint_nml)
82    
83        print *, "Enter namelist 'logic_nml'."
84        read(unit=*, nml=logic_nml)
85        write(unit_nml, nml=logic_nml)
86    
87      call read_comdissnew      call read_comdissnew
88    
89      print *, "Enter namelist 'conf_gcm_nml'."      print *, "Enter namelist 'conf_gcm_nml'."
90      read(unit=*, nml=conf_gcm_nml)      read(unit=*, nml=conf_gcm_nml)
91      write(unit=*, nml=conf_gcm_nml)      write(unit_nml, nml=conf_gcm_nml)
92    
93      IF (MOD(day_step, iperiod) /= 0) call abort_gcm(modname = "conf_gcm", &      IF (MOD(day_step, iperiod) /= 0) call abort_gcm(modname = "conf_gcm", &
94           message = &           message = &
95           'Il faut choisir un nombre de pas par jour multiple de "iperiod".', &           'Il faut choisir un nombre de pas par jour multiple de "iperiod".', &
96           ierr = 1)           ierr = 1)
97    
98      IF (MOD(day_step,iphysiq)/= 0) call abort_gcm(modname = "conf_gcm", &      IF (MOD(day_step, iphysiq)/= 0) call abort_gcm(modname = "conf_gcm", &
99           message = &           message = &
100           'Il faut choisir un nombre de pas par jour multiple de "iphysiq".', &           'Il faut choisir un nombre de pas par jour multiple de "iphysiq".', &
101           ierr = 1)           ierr = 1)
102    
     IF (grossismx < 1.) THEN  
        PRINT *, 'Error: grossismx < 1'  
        STOP 1  
     ELSE  
        alphax = 1. - 1. / grossismx  
     ENDIF  
     IF (grossismy < 1.) THEN  
        PRINT *, 'Error: grossismy < 1'  
        STOP 1  
     ELSE  
        alphay = 1. - 1. / grossismy  
     ENDIF  
     PRINT *, 'alphax = ', alphax  
     PRINT *, 'alphay = ', alphay  
   
103    END SUBROUTINE conf_gcm    END SUBROUTINE conf_gcm
104    
105  end module conf_gcm_m  end module conf_gcm_m

Legend:
Removed from v.40  
changed lines
  Added in v.115

  ViewVC Help
Powered by ViewVC 1.1.21