/[lmdze]/trunk/dyn3d/conf_gcm.f
ViewVC logotype

Diff of /trunk/dyn3d/conf_gcm.f

Parent Directory Parent Directory | Revision Log Revision Log | View Patch Patch

trunk/libf/dyn3d/conf_gcm.f90 revision 3 by guez, Wed Feb 27 13:16:39 2008 UTC trunk/dyn3d/conf_gcm.f revision 131 by guez, Fri Feb 27 16:44:07 2015 UTC
# Line 1  Line 1 
1  module conf_gcm_m  module conf_gcm_m
2    
   ! This module is clean: no C preprocessor directive, no include line  
   
3    IMPLICIT NONE    IMPLICIT NONE
4    
5    INTEGER:: nday= 10    INTEGER:: nday = 10 ! nombre de jours d'intégration
6    ! Nombre de jours d'integration    integer:: day_step = 240 ! nombre de pas par jour, multiple de iperiod
   ! On pourait aussi permettre des mois ou des annees !  
   
   integer:: day_step= 240 ! nombre de pas par jour, multiple de iperiod  
7    
8    integer:: iperiod= 5    integer:: iperiod = 5
9    ! periode pour le pas Matsuno (en pas de temps)    ! periode pour le pas Matsuno (en pas de temps)
10    
11    integer:: iapp_tracvl= 5    integer:: iapp_tracvl = 5
12    ! Should normally be equal to "iperiod"    ! Should normally be equal to "iperiod"
13    ! frequence du groupement des flux (en pas de temps)    ! frequence du groupement des flux (en pas de temps)
14    
15    integer:: iconser= 240    integer:: iconser = 240
16    ! periode de sortie des variables de controle    ! number of time steps between output of control variables
   ! (En pas de temps)  
17    
18    integer:: iecri= 1 ! période d'écriture du fichier "dyn_hist.nc" (en jours)    integer:: iecri = 1 ! time interval between outputs to "dyn_hist.nc" (in days)
19    
20    integer:: idissip= 10 ! periode de la dissipation (en pas)    integer:: iphysiq = 5
21      ! number of time steps of dynamics between calls to physics
22    
23    integer:: iphysiq= 5    logical:: raz_date = .false.
24    ! Help = Periode de la physique en pas de temps de la dynamique.    ! prise en compte de la date initiale de la namelist et remise à
25      ! zéro des compteurs de pas de temps (sinon on garde la date du
26      ! fichier restart)
27    
28    integer:: dayref = 1 ! jour de l'année de l'état initial    integer:: periodav = 1
29    ! (= 350 si 20 décembre par exemple)    ! time interval between outputs in the dynamical part, in days
30    
31    integer:: anneeref = 1998 ! Annee de l'etat initial (avec 4 chiffres)    logical:: offline = .FALSE.
32      ! permet de mettre en route la nouvelle parametrisation de l'eau liquide
33    
34    integer:: raz_date = 0 ! Remise a zero de la date initiale    integer:: prt_level = 0 ! niveau d'impression souhaité (0 = minimum)
   ! 0 pas de remise a zero, on garde la date du fichier restart  
   ! 1 prise en compte de la date de gcm.def avec remise a zero  
   ! des compteurs de pas de temps  
35    
36    REAL:: periodav= 1.    LOGICAL:: purmats= .FALSE.
37    ! periode de stockage fichier histmoy (en jour)    ! Help = Choix du schema d'integration temporel.
38      ! y = pure Matsuno sinon c'est du Matsuno-leapfrog
39    
40    logical, save:: offline    INTEGER:: iflag_phys = 1
41      ! contrôle l'appel à la physique :
42      ! 0 : pas de physique
43      ! 1 : physique normale (appel à phylmd, phymars...) (default)
44      ! 2 : rappel Newtonien pour la température + friction au sol
45    
46  contains  contains
47    
48    SUBROUTINE conf_gcm(clesphy0)    SUBROUTINE conf_gcm
49    
50      ! Auteurs : L. Fairhead, P. Le Van      ! Auteurs : L. Fairhead, P. Le Van
51      ! Version du 29/04/97      ! Version du 29/04/97
52    
53      ! Nouveaux paramètres nitergdiv, nitergrot, niterh, tetagdiv, tetagrot,      use abort_gcm_m, only: abort_gcm
     ! tetatemp ajoutés pour la dissipation.  
   
     ! Autre paramètre ajouté en fin de liste de tapedef : fxyhypb  
     ! Si fxyhypb = .TRUE., choix de la fonction à dérivée tangente  
     ! hyperbolique  
     ! Sinon, choix de fxynew, à dérivée sinusoïdale  
   
     ! On ne compare pas les valeurs des paramètres du zoom, grossismx,  
     ! grossismy, clon, clat, fxyhypb lues sur le fichier start avec  
     ! celles passées par run.def, au début du gcm.  
     ! Ces paramètres définissent entre autres la grille et doivent être  
     ! cohérents, sinon il y aura divergence du gcm.  
   
     use IOIPSL, only: getin  
     use dimens_m  
     use paramet_m  
54      use comdissnew, only: read_comdissnew      use comdissnew, only: read_comdissnew
55      use logic, only: iflag_phys, fxyhypb, ysinus, purmats, ok_guide      use unit_nml_m, only: unit_nml
56      use serre, only: clon, clat, grossismx, grossismy, alphax, alphay, &  
57           dzoomx, dzoomy, taux, tauy      namelist /conf_gcm_nml/ raz_date, nday, day_step, iperiod, iapp_tracvl, &
58      use clesphys, only: ok_limitvrai, ok_orolf, iflag_con, nbapp_rad, &           iconser, iecri, periodav, iphysiq, offline
59           ok_orodr, cycle_diurne, new_oliq, soil_model  
60      use iniprint, only: lunout, read_iniprint      namelist /iniprint_nml/ prt_level
61    
62      INTEGER, PARAMETER:: longcles = 20      namelist /logic_nml/ purmats, iflag_phys
   
     REAL, intent(out), optional:: clesphy0(longcles)  
   
     namelist /conf_gcm_nml/dayref, anneeref, raz_date, nday, day_step, &  
          iperiod, iapp_tracvl, iconser, iecri, periodav, idissip, purmats, &  
          ok_guide, iflag_phys, iphysiq, cycle_diurne, soil_model, new_oliq, &  
          ok_orodr, ok_orolf, ok_limitvrai, nbapp_rad, iflag_con, clon, clat, &  
          grossismx, grossismy, dzoomx, dzoomy, taux, tauy  
63    
64      !------------------------------------      !------------------------------------
65    
66      print *, "Call sequence information: conf_gcm"      print *, "Call sequence information: conf_gcm"
     call read_iniprint  
67    
68      print *, "Enter namelist 'conf_gcm_nml'."      print *, "Enter namelist 'iniprint_nml'."
69      read(unit=*, nml=conf_gcm_nml)      read(unit=*, nml=iniprint_nml)
70      write(unit=*, nml=conf_gcm_nml)      write(unit_nml, nml=iniprint_nml)
71    
72        print *, "Enter namelist 'logic_nml'."
73        read(unit=*, nml=logic_nml)
74        write(unit_nml, nml=logic_nml)
75    
76      call read_comdissnew      call read_comdissnew
77    
78      IF (lunout /= 5 .and. lunout /= 6) THEN      print *, "Enter namelist 'conf_gcm_nml'."
79         OPEN(lunout, FILE='lmdz.out')      read(unit=*, nml=conf_gcm_nml)
80      ENDIF      write(unit_nml, nml=conf_gcm_nml)
81    
82      if (present(clesphy0)) then      IF (MOD(day_step, iperiod) /= 0) call abort_gcm(modname = "conf_gcm", &
83         clesphy0(:) = 0.           message = &
84         clesphy0(1) = REAL(iflag_con)           'Il faut choisir un nombre de pas par jour multiple de "iperiod".', &
85         clesphy0(2) = REAL(nbapp_rad)           ierr = 1)
86    
87         IF (cycle_diurne) clesphy0(3) = 1.      IF (MOD(day_step, iphysiq)/= 0) call abort_gcm(modname = "conf_gcm", &
88         IF (soil_model) clesphy0(4) = 1.           message = &
89         IF (new_oliq) clesphy0(5) = 1.           'Il faut choisir un nombre de pas par jour multiple de "iphysiq".', &
90         IF (ok_orodr) clesphy0(6) = 1.           ierr = 1)
        IF (ok_orolf) clesphy0(7) = 1.  
        IF (ok_limitvrai) clesphy0(8) = 1.  
     end if  
   
     IF (grossismx < 1.) THEN  
        PRINT *, 'Error: grossismx < 1'  
        STOP 1  
     ELSE  
        alphax = 1. - 1. / grossismx  
     ENDIF  
     IF (grossismy < 1.) THEN  
        PRINT *, 'Error: grossismy < 1'  
        STOP 1  
     ELSE  
        alphay = 1. - 1. / grossismy  
     ENDIF  
     PRINT *, 'alphax = ', alphax  
     PRINT *, 'alphay = ', alphay  
   
     ! Key = fxyhypb  
     ! Desc = Fonction hyperbolique  
     ! Def = y  
     ! Help = Fonction f(y) hyperbolique si = .true.  
     ! sinon sinusoidale  
     fxyhypb = .TRUE.  
     CALL getin('fxyhypb', fxyhypb)  
   
     ! Key = ysinus  
     ! IF = !fxyhypb  
     ! Desc = Fonction en Sinus  
     ! Def = y  
     ! Help = Fonction f(y) avec y = Sin(latit.) si = .true.  
     ! sinon y = latit.  
     ysinus = .TRUE.  
     CALL getin('ysinus', ysinus)  
   
     ! Key = offline  
     ! Desc = Nouvelle eau liquide  
     ! Def = n  
     ! Help = Permet de mettre en route la  
     ! nouvelle parametrisation de l'eau liquide  
     offline = .FALSE.  
     CALL getin('offline', offline)  
     write(lunout, *)' offline = ', offline  
91    
92    END SUBROUTINE conf_gcm    END SUBROUTINE conf_gcm
93    

Legend:
Removed from v.3  
changed lines
  Added in v.131

  ViewVC Help
Powered by ViewVC 1.1.21