/[lmdze]/trunk/dyn3d/conf_guide.f
ViewVC logotype

Contents of /trunk/dyn3d/conf_guide.f

Parent Directory Parent Directory | Revision Log Revision Log


Revision 107 - (show annotations)
Thu Sep 11 15:09:15 2014 UTC (9 years, 8 months ago) by guez
File size: 1701 byte(s)
Imported procedure grilles_gcm_sub from LMDZ. Had then to transform
local variable phis of etat to argument.

Replaced calls to lnblnk by calls to trim.

Removed arguments nlat, klevel and griscal of filtreg. Replaced
integer arguments ifiltre and iaire by logical arguments direct and
intensive.

Changed default values of guide_t and guide_q to false.

1 module conf_guide_m
2
3 IMPLICIT NONE
4
5 ! Constantes de rappel. Unite : fraction de jour
6 REAL:: tau_min_u = 0.02
7 REAL:: tau_max_u = 10.
8 REAL:: tau_min_v = 0.02
9 REAL:: tau_max_v = 10.
10 REAL:: tau_min_t = 0.02
11 REAL:: tau_max_t = 10.
12 REAL:: tau_min_q = 0.02
13 REAL:: tau_max_q = 10.
14 REAL:: tau_min_p = 0.02
15 REAL:: tau_max_p = 10.
16
17 LOGICAL:: ncep = .false. ! Coordonnee vert NCEP ou ECMWF
18 LOGICAL:: ini_anal = .false. ! Initial = analyse
19 LOGICAL:: guide_u = .true. ! guidage de u
20 LOGICAL:: guide_v = .true. ! gvidage de v
21 LOGICAL:: guide_t = .false. ! guidage de T
22 LOGICAL:: guide_q = .false. ! guidage de q
23
24 logical:: online = .true. ! controle du guide
25 ! hors-ligne: x=x_rea
26
27 ! Latitude min et max pour le rappel dans le cas ou on 'a les
28 ! analyses que sur une bande de latitudes.
29 REAL:: lat_min_guide = -90. ! Latitude minimum pour le guidage
30 real:: lat_max_guide = 90. ! Latitude maximum pour le guidage
31
32 contains
33
34 SUBROUTINE conf_guide
35
36 ! From LMDZ4/libf/dyn3d/conf_guide.F, version 1.1.1.1 2004/05/19 12:53:07
37 ! Parametres de controle du run:
38
39 use unit_nml_m, only: unit_nml
40
41 namelist /conf_guide_nml/ ncep, ini_anal, guide_u, guide_v, guide_t, &
42 online, tau_min_u, tau_max_u, tau_min_v, tau_max_v, tau_min_t, &
43 tau_max_t, tau_min_q, tau_max_q, tau_min_p, tau_max_p, &
44 lat_min_guide, lat_max_guide
45
46 !-----------------------------------------------------------------------
47
48 print *, "Call sequence information: conf_guide"
49
50 print *, "Enter namelist 'conf_guide_nml'."
51 read(unit=*, nml=conf_guide_nml)
52 write(unit_nml, nml=conf_guide_nml)
53
54 end SUBROUTINE conf_guide
55
56 end module conf_guide_m