/[lmdze]/trunk/dyn3d/iniadvtrac.f
ViewVC logotype

Annotation of /trunk/dyn3d/iniadvtrac.f

Parent Directory Parent Directory | Revision Log Revision Log


Revision 134 - (hide annotations)
Wed Apr 29 15:47:56 2015 UTC (9 years, 1 month ago) by guez
Original Path: trunk/Sources/dyn3d/iniadvtrac.f
File size: 3891 byte(s)
Sources inside, compilation outside.
1 guez 18 module iniadvtrac_m
2 guez 3
3 guez 62 ! From advtrac.h, version 1.1.1.1 2004/05/19 12:53:06
4 guez 3
5 guez 62 ! iq = 1 pour l'eau vapeur
6     ! iq = 2 pour l'eau liquide
7 guez 78 ! et éventuellement iq = 3, ..., nqmx pour les autres traceurs
8 guez 62
9 guez 3 use dimens_m, only: nqmx
10    
11     implicit none
12    
13     private nqmx
14    
15 guez 78 INTEGER iadv(nqmx) ! indice du schéma d'advection pour l'eau et les traceurs
16     ! 11 means Van-Leer scheme for hadv et monotonous PPM for vadv
17 guez 62
18     integer, parameter:: allowed_adv(10) = (/0, 1, 2, 10, 12, 13, 14, 16, 17, 18/)
19     ! Allowed values for hadv and vadv:
20     ! 1: schema transport type "humidite specifique LMD"
21     ! 2: schema amont
22     ! 10: schema Van-leer (retenu pour l'eau vapeur et liquide)
23     ! 12: schema Frederic Hourdin I
24     ! 13: schema Frederic Hourdin II
25     ! 14: schema Van-leer + humidite specifique
26     ! 16: schema PPM Monotone(Collela & Woodward 1984)
27     ! 17: schema PPM Semi Monotone (overshoots autorisés)
28     ! 18: schema PPM Positif Defini (overshoots undershoots autorisés)
29     ! Pour Van-Leer plus vapeur d'eau saturée : iadv(1)=4
30    
31     INTEGER hadv(nqmx) ! indice schéma transport horizontal
32     INTEGER vadv(nqmx) ! indice schéma transport vertical
33 guez 131
34     character(len=10) tname(nqmx)
35     ! nom du traceur pour fichiers restart et historiques
36    
37 guez 3 character(len=13) ttext(nqmx) ! nom long du traceur pour sorties
38    
39     contains
40    
41 guez 23 subroutine iniadvtrac
42 guez 3
43     ! From dyn3d/iniadvtrac.F, version 1.3 2005/04/13 08:58:34
44    
45 guez 78 ! Authors: P. Le Van, L. Fairhead, F. Hourdin, F. Codron,
46 guez 62 ! F. Forget, M.-A. Filiberti
47 guez 3
48 guez 129 ! Initialisation des traceurs
49     ! Choix du schéma pour l'advection dans le fichier "traceur.def"
50    
51 guez 36 use nr_util, only: assert
52 guez 62 use jumble, only: new_unit
53 guez 3
54     ! Variables local to the procedure:
55    
56 guez 62 character(len=3) descrq(18)
57     integer iq, iostat, nq_local, unit
58 guez 3
59     !-----------------------------------------------------------------------
60    
61     print *, "Call sequence information: iniadvtrac"
62    
63     ! Initializations:
64     descrq(10)='VL1'
65     descrq(11)='VLP'
66     descrq(12)='FH1'
67     descrq(13)='FH2'
68 guez 62 descrq(14)='VLH'
69 guez 3 descrq(16)='PPM'
70     descrq(17)='PPS'
71     descrq(18)='PPP'
72    
73 guez 62 ! Choix du schéma pour l'advection dans fichier "traceur.def"
74     call new_unit(unit)
75     open(unit, file='traceur.def', status='old', action="read", &
76     position="rewind", iostat=iostat)
77     if (iostat == 0) then
78 guez 3 print *, 'Ouverture de "traceur.def" ok'
79 guez 62 read(unit, fmt=*) nq_local
80 guez 5 print *, 'nombre de traceurs ', nq_local
81 guez 23 call assert(nq_local == nqmx, "iniadvtrac nq_local")
82 guez 3
83 guez 23 do iq=1, nqmx
84 guez 131 read(unit, fmt=*) hadv(iq), vadv(iq), tname(iq)
85 guez 62 if (.not. any(hadv(iq) == allowed_adv) &
86     .or. .not. any(vadv(iq) == allowed_adv)) then
87     print *, "bad number for advection scheme"
88     stop 1
89     end if
90 guez 3 end do
91 guez 62 close(unit)
92 guez 3 else
93 guez 5 print *, 'Problème à l''ouverture de "traceur.def"'
94     print *, 'Attention : on prend des valeurs par défaut.'
95 guez 23 call assert(nqmx == 4, "iniadvtrac nqmx")
96 guez 78 hadv(:4) = (/14, 10, 10, 10/)
97     vadv(:4) = hadv(:4)
98 guez 131 tname(1) = 'H2Ov'
99     tname(2) = 'H2Ol'
100     tname(3) = 'RN'
101     tname(4) = 'PB'
102 guez 62 do iq = 1, nqmx
103 guez 131 print *, hadv(iq), vadv(iq), tname(iq)
104 guez 62 end do
105 guez 3 ENDIF
106    
107     ! À partir du nom court du traceur et du schéma d'advection, on
108 guez 62 ! détermine le nom long :
109 guez 78 do iq = 1, nqmx
110 guez 3 if (hadv(iq) /= vadv(iq)) then
111 guez 62 if (hadv(iq) == 10 .and. vadv(iq) == 16) then
112 guez 78 iadv(iq) = 11
113 guez 3 else
114 guez 62 print *, "Bad combination for hozizontal and vertical schemes."
115     stop 1
116 guez 3 endif
117     else
118 guez 78 iadv(iq) = hadv(iq)
119 guez 3 endif
120    
121 guez 62 IF (iadv(iq) == 0) THEN
122 guez 131 ttext(iq) = tname(iq)
123 guez 3 ELSE
124 guez 131 ttext(iq)=trim(tname(iq)) // descrq(iadv(iq))
125 guez 3 endif
126     end do
127    
128     END subroutine iniadvtrac
129    
130 guez 18 end module iniadvtrac_m

  ViewVC Help
Powered by ViewVC 1.1.21