/[lmdze]/trunk/dyn3d/iniadvtrac.f
ViewVC logotype

Annotation of /trunk/dyn3d/iniadvtrac.f

Parent Directory Parent Directory | Revision Log Revision Log


Revision 78 - (hide annotations)
Wed Feb 5 17:51:07 2014 UTC (10 years, 3 months ago) by guez
Original Path: trunk/dyn3d/iniadvtrac.f90
File size: 3918 byte(s)
Moved procedure inigeom into module comgeom.

In disvert, renamed s_sampling to vert_sampling, following
LMDZ. Removed choice strato1. In case read, read ap and bp instead of
s (following LMDZ).

Added argument phis to start_init_orog and start_init_dyn, and removed
variable phis of module start_init_orog_m. In etat0 and
start_init_orog, renamed relief to zmea_2d. In start_init_dyn, renamed
psol to ps.

In start_init_orog, renamed relief_hi to relief. No need to set
phis(iim + 1, :) = phis(1, :), already done in grid_noro.

Documentation for massbar out of SVN, in massbar.txt. Documentation
was duplicated in massdair, but not relevant in massdair.

In conflx, no need to initialize pen_[ud] and pde_[ud]. In flxasc,
used intermediary variable fact (following LMDZ).

In grid_noro, added local variable zmea0 for zmea not smoothed and
computed zphi from zmea instead of zmea0 (following LMDZ). This
changes the results of ce0l.

Removed arguments pen_u and pde_d of phytrac and nflxtr, which were
not used.

1 guez 18 module iniadvtrac_m
2 guez 3
3 guez 62 ! From advtrac.h, version 1.1.1.1 2004/05/19 12:53:06
4 guez 3
5 guez 62 ! iq = 1 pour l'eau vapeur
6     ! iq = 2 pour l'eau liquide
7 guez 78 ! et éventuellement iq = 3, ..., nqmx pour les autres traceurs
8 guez 62
9 guez 3 use dimens_m, only: nqmx
10    
11     implicit none
12    
13     private nqmx
14    
15 guez 78 INTEGER iadv(nqmx) ! indice du schéma d'advection pour l'eau et les traceurs
16     ! 11 means Van-Leer scheme for hadv et monotonous PPM for vadv
17 guez 62
18     integer, parameter:: allowed_adv(10) = (/0, 1, 2, 10, 12, 13, 14, 16, 17, 18/)
19     ! Allowed values for hadv and vadv:
20     ! 1: schema transport type "humidite specifique LMD"
21     ! 2: schema amont
22     ! 10: schema Van-leer (retenu pour l'eau vapeur et liquide)
23     ! 12: schema Frederic Hourdin I
24     ! 13: schema Frederic Hourdin II
25     ! 14: schema Van-leer + humidite specifique
26     ! 16: schema PPM Monotone(Collela & Woodward 1984)
27     ! 17: schema PPM Semi Monotone (overshoots autorisés)
28     ! 18: schema PPM Positif Defini (overshoots undershoots autorisés)
29     ! Pour Van-Leer plus vapeur d'eau saturée : iadv(1)=4
30    
31     INTEGER hadv(nqmx) ! indice schéma transport horizontal
32     INTEGER vadv(nqmx) ! indice schéma transport vertical
33     INTEGER niadv(nqmx) ! équivalent dynamique / physique
34 guez 3 character(len=8) tnom(nqmx) ! nom court du traceur
35     character(len=10) tname(nqmx) ! nom du traceur pour restart
36     character(len=13) ttext(nqmx) ! nom long du traceur pour sorties
37    
38     contains
39    
40 guez 23 subroutine iniadvtrac
41 guez 3
42     ! From dyn3d/iniadvtrac.F, version 1.3 2005/04/13 08:58:34
43    
44 guez 78 ! Authors: P. Le Van, L. Fairhead, F. Hourdin, F. Codron,
45 guez 62 ! F. Forget, M.-A. Filiberti
46 guez 3
47 guez 36 use nr_util, only: assert
48 guez 62 use jumble, only: new_unit
49 guez 3
50     ! Variables local to the procedure:
51    
52 guez 62 character(len=3) descrq(18)
53     integer iq, iostat, nq_local, unit
54 guez 3
55     !-----------------------------------------------------------------------
56    
57     print *, "Call sequence information: iniadvtrac"
58    
59     ! Initializations:
60     descrq(10)='VL1'
61     descrq(11)='VLP'
62     descrq(12)='FH1'
63     descrq(13)='FH2'
64 guez 62 descrq(14)='VLH'
65 guez 3 descrq(16)='PPM'
66     descrq(17)='PPS'
67     descrq(18)='PPP'
68    
69 guez 62 ! Choix du schéma pour l'advection dans fichier "traceur.def"
70     call new_unit(unit)
71     open(unit, file='traceur.def', status='old', action="read", &
72     position="rewind", iostat=iostat)
73     if (iostat == 0) then
74 guez 3 print *, 'Ouverture de "traceur.def" ok'
75 guez 62 read(unit, fmt=*) nq_local
76 guez 5 print *, 'nombre de traceurs ', nq_local
77 guez 23 call assert(nq_local == nqmx, "iniadvtrac nq_local")
78 guez 3
79 guez 23 do iq=1, nqmx
80 guez 62 read(unit, fmt=*) hadv(iq), vadv(iq), tnom(iq)
81     if (.not. any(hadv(iq) == allowed_adv) &
82     .or. .not. any(vadv(iq) == allowed_adv)) then
83     print *, "bad number for advection scheme"
84     stop 1
85     end if
86 guez 3 end do
87 guez 62 close(unit)
88 guez 3 else
89 guez 5 print *, 'Problème à l''ouverture de "traceur.def"'
90     print *, 'Attention : on prend des valeurs par défaut.'
91 guez 23 call assert(nqmx == 4, "iniadvtrac nqmx")
92 guez 78 hadv(:4) = (/14, 10, 10, 10/)
93     vadv(:4) = hadv(:4)
94 guez 3 tnom(1) = 'H2Ov'
95     tnom(2) = 'H2Ol'
96     tnom(3) = 'RN'
97     tnom(4) = 'PB'
98 guez 62 do iq = 1, nqmx
99     print *, hadv(iq), vadv(iq), tnom(iq)
100     end do
101 guez 3 ENDIF
102    
103 guez 62 tname = tnom
104    
105 guez 3 ! À partir du nom court du traceur et du schéma d'advection, on
106 guez 62 ! détermine le nom long :
107 guez 78 do iq = 1, nqmx
108 guez 3 if (hadv(iq) /= vadv(iq)) then
109 guez 62 if (hadv(iq) == 10 .and. vadv(iq) == 16) then
110 guez 78 iadv(iq) = 11
111 guez 3 else
112 guez 62 print *, "Bad combination for hozizontal and vertical schemes."
113     stop 1
114 guez 3 endif
115     else
116 guez 78 iadv(iq) = hadv(iq)
117 guez 3 endif
118    
119 guez 62 IF (iadv(iq) == 0) THEN
120     ttext(iq) = tnom(iq)
121 guez 3 ELSE
122 guez 62 ttext(iq)=trim(tnom(iq)) // descrq(iadv(iq))
123 guez 3 endif
124     end do
125    
126 guez 62 forall (iq = 1: nqmx) niadv(iq)=iq
127 guez 3
128     END subroutine iniadvtrac
129    
130 guez 18 end module iniadvtrac_m

  ViewVC Help
Powered by ViewVC 1.1.21