/[lmdze]/trunk/libf/dyn3d/Dissipation
ViewVC logotype

Log of /trunk/libf/dyn3d/Dissipation

View Directory Listing Directory Listing


Sticky Revision:
(Current path doesn't exist after revision 75)

Revision 60 - Directory Listing
Modified Mon Jan 30 14:37:26 2012 UTC (12 years, 4 months ago) by guez
Useless copies into "gdx" and "gdy" in "gradiv2".


Revision 57 - Directory Listing
Modified Mon Jan 30 12:54:02 2012 UTC (12 years, 4 months ago) by guez
Write used namelists to file "" instead of standard output.

Avoid aliasing in "inidissip" in calls to "divgrad2", "divgrad",
"gradiv2", "gradiv", "nxgraro2" and "nxgrarot". Add a degenerate
dimension to arrays so they have rank 3, like the dummy arguments in
"divgrad2", "divgrad", "gradiv2", "gradiv", "nxgraro2" and "nxgrarot".

Extract the initialization part from "bilan_dyn" and make a separate
procedure, "init_dynzon", from it.

Move variables from modules "iniprint" and "logic" to module
"conf_gcm_m".

Promote internal procedures of "fxy" to private procedures of module
"fxy_m".

Extracted documentation from "inigeom". Removed useless "save"
attributes. Removed useless intermediate variables. Extracted
processing of poles from loop on latitudes. Write coordinates to file
"longitude_latitude.txt" instead of standard output.

Do not use ozone tracer for radiative transfer.


Revision 56 - Directory Listing
Modified Tue Jan 10 19:02:02 2012 UTC (12 years, 4 months ago) by guez
Imported "writehist.f" from LMDZ.

Moved module variable "histaveid" from "com_io_dyn" to "initdynav_m".

In "inithist", access directly module variables from "com_io_dyn"
instead of going through the arguments. Copying from LMDZ, write "u"
and scalar variables to separate files. Create a new variable for the
new file in "com_io_dyn". Copying from LMDZ, change the vertical axes
of the three files.

Removed some useless initializations in "dissip".

In "bilan_dyn", removed useless variable "time". Avoiding the
approximate test on "dt_cum" being a multiple of "dt_app", just
compute "ncum" from known usage of "bilan_dyn" and compute "dt_cum"
from "ncum". Change "periodav" from real to integer in
"conf_gcm_m". Since "day_step" is required to be a multiple of
"iperiod", so is "ncum".


Revision 55 - Directory Listing
Added Mon Dec 12 13:25:01 2011 UTC (12 years, 5 months ago) by guez
-- In procedure "bilan_dyn", replaced average of "zvq" by integral of
"zvq", following a comment of Francis Codron :

Le calcul actuel donne des unités peu pratiques : transports de
chaleur en K m / s par exemple. C'est bien pour les sorties à 2
dimensions, latitude et pression, car alors le transport ne dépend pas
de l'espacement des niveaux, mieux pour comparer ou tracer en latitude
et pression. Par contre, quand on somme sur la verticale, on
préfèrerait avoir des transports d'énergie en watts, ou au moins an K
kg / s (à multiplier par "Cp" ou "L"). On doit pouvoir recalculer le
transport intégré à partir des fichiers de sortie, mais c'est embêtant
(calcul de "cv").

-- Gathered files in directory Dissipation.


  ViewVC Help
Powered by ViewVC 1.1.21