/[lmdze]/trunk/libf/dyn3d/laplacien.f
ViewVC logotype

Log of /trunk/libf/dyn3d/laplacien.f

Parent Directory Parent Directory | Revision Log Revision Log


Sticky Revision:
(Current path doesn't exist after revision 60)

Revision 60 - (view) (annotate) - [select for diffs]
Modified Mon Jan 30 14:37:26 2012 UTC (12 years, 2 months ago) by guez
File length: 1276 byte(s)
Diff to previous 57
Useless copies into "gdx" and "gdy" in "gradiv2".


Revision 57 - (view) (annotate) - [select for diffs]
Modified Mon Jan 30 12:54:02 2012 UTC (12 years, 2 months ago) by guez
File length: 1247 byte(s)
Diff to previous 55
Write used namelists to file "" instead of standard output.

Avoid aliasing in "inidissip" in calls to "divgrad2", "divgrad",
"gradiv2", "gradiv", "nxgraro2" and "nxgrarot". Add a degenerate
dimension to arrays so they have rank 3, like the dummy arguments in
"divgrad2", "divgrad", "gradiv2", "gradiv", "nxgraro2" and "nxgrarot".

Extract the initialization part from "bilan_dyn" and make a separate
procedure, "init_dynzon", from it.

Move variables from modules "iniprint" and "logic" to module
"conf_gcm_m".

Promote internal procedures of "fxy" to private procedures of module
"fxy_m".

Extracted documentation from "inigeom". Removed useless "save"
attributes. Removed useless intermediate variables. Extracted
processing of poles from loop on latitudes. Write coordinates to file
"longitude_latitude.txt" instead of standard output.

Do not use ozone tracer for radiative transfer.


Revision 55 - (view) (annotate) - [select for diffs]
Modified Mon Dec 12 13:25:01 2011 UTC (12 years, 4 months ago) by guez
File length: 1211 byte(s)
Diff to previous 27
-- In procedure "bilan_dyn", replaced average of "zvq" by integral of
"zvq", following a comment of Francis Codron :

Le calcul actuel donne des unités peu pratiques : transports de
chaleur en K m / s par exemple. C'est bien pour les sorties à 2
dimensions, latitude et pression, car alors le transport ne dépend pas
de l'espacement des niveaux, mieux pour comparer ou tracer en latitude
et pression. Par contre, quand on somme sur la verticale, on
préfèrerait avoir des transports d'énergie en watts, ou au moins an K
kg / s (à multiplier par "Cp" ou "L"). On doit pouvoir recalculer le
transport intégré à partir des fichiers de sortie, mais c'est embêtant
(calcul de "cv").

-- Gathered files in directory Dissipation.


Revision 27 - (view) (annotate) - [select for diffs]
Modified Thu Mar 25 14:29:07 2010 UTC (14 years, 1 month ago) by guez
File length: 1197 byte(s)
Diff to previous 3
"dyn3d" and "filtrez" do not contain any included file so make rules
have been updated.

"comdissip.f90" was useless, removed it.

"dynredem0" wrote undefined value in "controle(31)", that was
overwritten by "dynredem1". Now "dynredem0" just writes 0 to
"controle(31)".

Removed arguments of "inidissip". "inidissip" now accesses the
variables by use association.

In program "etat0_lim", "itaufin" is not defined so "dynredem1" wrote
undefined value to "controle(31)". Added argument "itau" of
"dynredem1" to correct that.

"itaufin" does not need to be a module variable (of "temps"), made it
a local variable of "leapfrog".

Removed calls to "diagedyn" from "leapfrog".


Revision 3 - (view) (annotate) - [select for diffs]
Added Wed Feb 27 13:16:39 2008 UTC (16 years, 2 months ago) by guez
File length: 1162 byte(s)
Initial import

This form allows you to request diffs between any two revisions of this file. For each of the two "sides" of the diff, enter a numeric revision.

  Diffs between and
  Type of Diff should be a

  ViewVC Help
Powered by ViewVC 1.1.21