1 |
SUBROUTINE flxsetup |
2 |
use yoecumf |
3 |
IMPLICIT none |
4 |
! |
5 |
! THIS ROUTINE DEFINES DISPOSABLE PARAMETERS FOR MASSFLUX SCHEME |
6 |
! |
7 |
! |
8 |
ENTRPEN=1.0E-4 ! ENTRAINMENT RATE FOR PENETRATIVE CONVECTION |
9 |
ENTRSCV=3.0E-4 ! ENTRAINMENT RATE FOR SHALLOW CONVECTION |
10 |
ENTRMID=1.0E-4 ! ENTRAINMENT RATE FOR MIDLEVEL CONVECTION |
11 |
ENTRDD =2.0E-4 ! ENTRAINMENT RATE FOR DOWNDRAFTS |
12 |
CMFCTOP=0.33 ! RELATIVE CLOUD MASSFLUX AT LEVEL ABOVE NONBUO LEVEL |
13 |
CMFCMAX=1.0 ! MAXIMUM MASSFLUX VALUE ALLOWED FOR UPDRAFTS ETC |
14 |
CMFCMIN=1.E-10 ! MINIMUM MASSFLUX VALUE (FOR SAFETY) |
15 |
CMFDEPS=0.3 ! FRACTIONAL MASSFLUX FOR DOWNDRAFTS AT LFS |
16 |
CPRCON =2.0E-4 ! CONVERSION FROM CLOUD WATER TO RAIN |
17 |
RHCDD=1. ! RELATIVE SATURATION IN DOWNDRAFRS (NO LONGER USED) |
18 |
! (FORMULATION IMPLIES SATURATION) |
19 |
LMFPEN = .TRUE. |
20 |
LMFSCV = .TRUE. |
21 |
LMFMID = .TRUE. |
22 |
LMFDD = .TRUE. |
23 |
LMFDUDV = .TRUE. |
24 |
! |
25 |
RETURN |
26 |
END |