/[lmdze]/trunk/phylmd/cv_driver.f90
ViewVC logotype

Diff of /trunk/phylmd/cv_driver.f90

Parent Directory Parent Directory | Revision Log Revision Log | View Patch Patch

revision 145 by guez, Tue Jun 16 15:23:29 2015 UTC revision 195 by guez, Wed May 18 17:56:44 2016 UTC
# Line 4  module cv_driver_m Line 4  module cv_driver_m
4    
5  contains  contains
6    
7    SUBROUTINE cv_driver(t1, q1, qs1, u1, v1, p1, ph1, iflag1, ft1, &    SUBROUTINE cv_driver(t1, q1, qs1, u1, v1, p1, ph1, iflag1, ft1, fq1, fu1, &
8         fq1, fu1, fv1, precip1, VPrecip1, cbmf1, sig1, w01, icb1, inb1, delt, &         fv1, precip1, VPrecip1, sig1, w01, icb1, inb1, Ma1, upwd1, dnwd1, &
9         Ma1, upwd1, dnwd1, dnwd01, qcondc1, wd1, cape1, da1, phi1, mp1)         dnwd01, qcondc1, cape1, da1, phi1, mp1)
10    
11      ! From LMDZ4/libf/phylmd/cv_driver.F, version 1.3, 2005/04/15 12:36:17      ! From LMDZ4/libf/phylmd/cv_driver.F, version 1.3, 2005/04/15 12:36:17
12      ! Main driver for convection      ! Main driver for convection
# Line 14  contains Line 14  contains
14    
15      ! Several modules corresponding to different physical processes      ! Several modules corresponding to different physical processes
16    
17      ! Several versions of convect may be used:      use comconst, only: dtphys
18      ! - iflag_con = 3: version lmd      use cv30_closure_m, only: cv30_closure
19      ! - iflag_con = 4: version 4.3b      use cv30_compress_m, only: cv30_compress
20        use cv30_feed_m, only: cv30_feed
21      use clesphys2, only: iflag_con      use cv30_mixing_m, only: cv30_mixing
22      use cv3_compress_m, only: cv3_compress      use cv30_param_m, only: cv30_param, nl
23      use cv3_feed_m, only: cv3_feed      use cv30_prelim_m, only: cv30_prelim
24      use cv3_mixing_m, only: cv3_mixing      use cv30_tracer_m, only: cv30_tracer
25      use cv3_param_m, only: cv3_param      use cv30_trigger_m, only: cv30_trigger
26      use cv3_prelim_m, only: cv3_prelim      use cv30_uncompress_m, only: cv30_uncompress
27      use cv3_tracer_m, only: cv3_tracer      use cv30_undilute1_m, only: cv30_undilute1
28      use cv3_uncompress_m, only: cv3_uncompress      use cv30_undilute2_m, only: cv30_undilute2
29      use cv3_unsat_m, only: cv3_unsat      use cv30_unsat_m, only: cv30_unsat
30      use cv3_yield_m, only: cv3_yield      use cv30_yield_m, only: cv30_yield
31      use cv_feed_m, only: cv_feed      use cv_thermo_m, only: cv_thermo
     use cv_uncompress_m, only: cv_uncompress  
32      USE dimphy, ONLY: klev, klon      USE dimphy, ONLY: klev, klon
33    
34      real, intent(in):: t1(klon, klev) ! temperature      real, intent(in):: t1(klon, klev) ! temperature (K)
35      real, intent(in):: q1(klon, klev) ! specific hum      real, intent(in):: q1(klon, klev) ! specific humidity
36      real, intent(in):: qs1(klon, klev) ! sat specific hum      real, intent(in):: qs1(klon, klev) ! saturation specific humidity
37      real, intent(in):: u1(klon, klev) ! u-wind  
38      real, intent(in):: v1(klon, klev) ! v-wind      real, intent(in):: u1(klon, klev), v1(klon, klev)
39      real, intent(in):: p1(klon, klev) ! full level pressure      ! zonal wind and meridional velocity (m/s)
40      real, intent(in):: ph1(klon, klev + 1) ! half level pressure  
41      integer, intent(out):: iflag1(klon) ! flag for Emanuel conditions      real, intent(in):: p1(klon, klev) ! full level pressure (hPa)
42      real, intent(out):: ft1(klon, klev) ! temp tend  
43      real, intent(out):: fq1(klon, klev) ! spec hum tend      real, intent(in):: ph1(klon, klev + 1)
44      real, intent(out):: fu1(klon, klev) ! u-wind tend      ! Half level pressure (hPa). These pressures are defined at levels
45      real, intent(out):: fv1(klon, klev) ! v-wind tend      ! intermediate between those of P1, T1, Q1 and QS1. The first
46      real, intent(out):: precip1(klon) ! precipitation      ! value of PH should be greater than (i.e. at a lower level than)
47        ! the first value of the array P1.
48    
49      real, intent(out):: VPrecip1(klon, klev+1)      integer, intent(out):: iflag1(klon)
50      ! vertical profile of precipitation      ! Flag for Emanuel conditions.
51    
52      real, intent(inout):: cbmf1(klon) ! cloud base mass flux      ! 0: Moist convection occurs.
     real, intent(inout):: sig1(klon, klev) ! section adiabatic updraft  
53    
54      real, intent(inout):: w01(klon, klev)      ! 1: Moist convection occurs, but a CFL condition on the
55      ! vertical velocity within adiabatic updraft      ! subsidence warming is violated. This does not cause the scheme
56        ! to terminate.
57    
58      integer, intent(out):: icb1(klon)      ! 2: Moist convection, but no precipitation because ep(inb) < 1e-4
     integer, intent(inout):: inb1(klon)  
     real, intent(in):: delt ! time step  
     real Ma1(klon, klev)  
     ! Ma1 Real Output mass flux adiabatic updraft  
     real, intent(out):: upwd1(klon, klev) ! total upward mass flux (adiab+mixed)  
     real, intent(out):: dnwd1(klon, klev) ! saturated downward mass flux (mixed)  
     real, intent(out):: dnwd01(klon, klev) ! unsaturated downward mass flux  
59    
60      real qcondc1(klon, klev) ! cld      ! 3: No moist convection because new cbmf is 0 and old cbmf is 0.
     ! qcondc1 Real Output in-cld mixing ratio of condensed water  
     real wd1(klon) ! gust  
     ! wd1 Real Output downdraft velocity scale for sfc fluxes  
     real cape1(klon)  
     ! cape1 Real Output CAPE  
61    
62      real, intent(inout):: da1(klon, klev), phi1(klon, klev, klev)      ! 4: No moist convection; atmosphere is not unstable.
     real, intent(inout):: mp1(klon, klev)  
   
     ! --- ARGUMENTS  
63    
64      ! --- On input:      ! 6: No moist convection because ihmin <= minorig.
   
     ! t: Array of absolute temperature (K) of dimension KLEV, with first  
     ! index corresponding to lowest model level. Note that this array  
     ! will be altered by the subroutine if dry convective adjustment  
     ! occurs and if IPBL is not equal to 0.  
   
     ! q: Array of specific humidity (gm/gm) of dimension KLEV, with first  
     ! index corresponding to lowest model level. Must be defined  
     ! at same grid levels as T. Note that this array will be altered  
     ! if dry convective adjustment occurs and if IPBL is not equal to 0.  
   
     ! qs: Array of saturation specific humidity of dimension KLEV, with first  
     ! index corresponding to lowest model level. Must be defined  
     ! at same grid levels as T. Note that this array will be altered  
     ! if dry convective adjustment occurs and if IPBL is not equal to 0.  
   
     ! u: Array of zonal wind velocity (m/s) of dimension KLEV, witth first  
     ! index corresponding with the lowest model level. Defined at  
     ! same levels as T. Note that this array will be altered if  
     ! dry convective adjustment occurs and if IPBL is not equal to 0.  
   
     ! v: Same as u but for meridional velocity.  
   
     ! p: Array of pressure (mb) of dimension KLEV, with first  
     ! index corresponding to lowest model level. Must be defined  
     ! at same grid levels as T.  
   
     ! ph: Array of pressure (mb) of dimension KLEV+1, with first index  
     ! corresponding to lowest level. These pressures are defined at  
     ! levels intermediate between those of P, T, Q and QS. The first  
     ! value of PH should be greater than (i.e. at a lower level than)  
     ! the first value of the array P.  
65    
66      ! nl: The maximum number of levels to which convection can penetrate, plus 1      ! 7: No moist convection because unreasonable parcel level
67      ! NL MUST be less than or equal to KLEV-1.      ! temperature or specific humidity.
68    
69      ! delt: The model time step (sec) between calls to CONVECT      ! 8: No moist convection: lifted condensation level is above the
70        ! 200 mbar level.
71    
72      ! --- On Output:      ! 9: No moist convection: cloud base is higher than the level NL-1.
73    
74      ! iflag: An output integer whose value denotes the following:      real, intent(out):: ft1(klon, klev) ! temperature tendency (K/s)
75      ! VALUE INTERPRETATION      real, intent(out):: fq1(klon, klev) ! specific humidity tendency (s-1)
     ! ----- --------------  
     ! 0 Moist convection occurs.  
     ! 1 Moist convection occurs, but a CFL condition  
     ! on the subsidence warming is violated. This  
     ! does not cause the scheme to terminate.  
     ! 2 Moist convection, but no precip because ep(inb) lt 0.0001  
     ! 3 No moist convection because new cbmf is 0 and old cbmf is 0.  
     ! 4 No moist convection; atmosphere is not  
     ! unstable  
     ! 6 No moist convection because ihmin le minorig.  
     ! 7 No moist convection because unreasonable  
     ! parcel level temperature or specific humidity.  
     ! 8 No moist convection: lifted condensation  
     ! level is above the 200 mb level.  
     ! 9 No moist convection: cloud base is higher  
     ! then the level NL-1.  
76    
77      ! ft: Array of temperature tendency (K/s) of dimension KLEV, defined at same      real, intent(out):: fu1(klon, klev), fv1(klon, klev)
78      ! grid levels as T, Q, QS and P.      ! forcing (tendency) of zonal and meridional velocity (m/s^2)
79    
80      ! fq: Array of specific humidity tendencies ((gm/gm)/s) of dimension KLEV,      real, intent(out):: precip1(klon) ! convective precipitation rate (mm/day)
     ! defined at same grid levels as T, Q, QS and P.  
81    
82      ! fu: Array of forcing of zonal velocity (m/s^2) of dimension KLEV,      real, intent(out):: VPrecip1(klon, klev + 1)
83      ! defined at same grid levels as T.      ! vertical profile of convective precipitation (kg/m2/s)
84    
85      ! fv: Same as FU, but for forcing of meridional velocity.      real, intent(inout):: sig1(klon, klev) ! section of adiabatic updraft
86    
87      ! precip: Scalar convective precipitation rate (mm/day).      real, intent(inout):: w01(klon, klev)
88        ! vertical velocity within adiabatic updraft
     ! VPrecip: Vertical profile of convective precipitation (kg/m2/s).  
89    
90      ! wd: A convective downdraft velocity scale. For use in surface      integer, intent(out):: icb1(klon)
91      ! flux parameterizations. See convect.ps file for details.      integer, intent(inout):: inb1(klon)
92        real, intent(out):: Ma1(klon, klev) ! mass flux of adiabatic updraft
93    
94      ! tprime: A convective downdraft temperature perturbation scale (K).      real, intent(out):: upwd1(klon, klev)
95      ! For use in surface flux parameterizations. See convect.ps      ! total upward mass flux (adiabatic + mixed)
     ! file for details.  
96    
97      ! qprime: A convective downdraft specific humidity      real, intent(out):: dnwd1(klon, klev) ! saturated downward mass flux (mixed)
98      ! perturbation scale (gm/gm).      real, intent(out):: dnwd01(klon, klev) ! unsaturated downward mass flux
     ! For use in surface flux parameterizations. See convect.ps  
     ! file for details.  
99    
100      ! cbmf: The cloud base mass flux ((kg/m**2)/s). THIS SCALAR VALUE MUST      real, intent(out):: qcondc1(klon, klev)
101      ! BE STORED BY THE CALLING PROGRAM AND RETURNED TO CONVECT AT      ! in-cloud mixing ratio of condensed water
     ! ITS NEXT CALL. That is, the value of CBMF must be "remembered"  
     ! by the calling program between calls to CONVECT.  
102    
103      ! det: Array of detrainment mass flux of dimension KLEV.      real, intent(out):: cape1(klon)
104        real, intent(inout):: da1(klon, klev), phi1(klon, klev, klev)
105        real, intent(inout):: mp1(klon, klev)
106    
107      ! Local arrays      ! Local:
108    
109      real da(klon, klev), phi(klon, klev, klev), mp(klon, klev)      real da(klon, klev), phi(klon, klev, klev), mp(klon, klev)
   
110      integer i, k, il      integer i, k, il
111      integer icbmax      integer icbmax
112      integer nk1(klon)      integer nk1(klon)
113      integer icbs1(klon)      integer icbs1(klon)
   
114      real plcl1(klon)      real plcl1(klon)
115      real tnk1(klon)      real tnk1(klon)
116      real qnk1(klon)      real qnk1(klon)
117      real gznk1(klon)      real gznk1(klon)
118      real pbase1(klon)      real pbase1(klon)
119      real buoybase1(klon)      real buoybase1(klon)
   
120      real lv1(klon, klev)      real lv1(klon, klev)
121      real cpn1(klon, klev)      real cpn1(klon, klev)
122      real tv1(klon, klev)      real tv1(klon, klev)
# Line 196  contains Line 127  contains
127      real tvp1(klon, klev)      real tvp1(klon, klev)
128      real clw1(klon, klev)      real clw1(klon, klev)
129      real th1(klon, klev)      real th1(klon, klev)
   
130      integer ncum      integer ncum
131    
132      ! (local) compressed fields:      ! Compressed fields:
   
133      integer idcum(klon)      integer idcum(klon)
134      integer iflag(klon), nk(klon), icb(klon)      integer iflag(klon), nk(klon)
135        integer, allocatable:: icb(:) ! (ncum)
136      integer nent(klon, klev)      integer nent(klon, klev)
137      integer icbs(klon)      integer icbs(klon)
138      integer inb(klon), inbis(klon)      integer inb(klon)
139        real plcl(klon), tnk(klon), qnk(klon), gznk(klon)
     real cbmf(klon), plcl(klon), tnk(klon), qnk(klon), gznk(klon)  
140      real t(klon, klev), q(klon, klev), qs(klon, klev)      real t(klon, klev), q(klon, klev), qs(klon, klev)
141      real u(klon, klev), v(klon, klev)      real u(klon, klev), v(klon, klev)
142      real gz(klon, klev), h(klon, klev), lv(klon, klev), cpn(klon, klev)      real gz(klon, klev), h(klon, klev), lv(klon, klev), cpn(klon, klev)
143      real p(klon, klev), ph(klon, klev+1), tv(klon, klev), tp(klon, klev)      real p(klon, klev) ! pressure at full level, in hPa
144        real ph(klon, klev + 1), tv(klon, klev), tp(klon, klev)
145      real clw(klon, klev)      real clw(klon, klev)
     real dph(klon, klev)  
146      real pbase(klon), buoybase(klon), th(klon, klev)      real pbase(klon), buoybase(klon), th(klon, klev)
147      real tvp(klon, klev)      real tvp(klon, klev)
148      real sig(klon, klev), w0(klon, klev)      real sig(klon, klev), w0(klon, klev)
149      real hp(klon, klev), ep(klon, klev), sigp(klon, klev)      real hp(klon, klev), ep(klon, klev)
150      real frac(klon), buoy(klon, klev)      real buoy(klon, klev)
151      real cape(klon)      real cape(klon)
152      real m(klon, klev), ment(klon, klev, klev), qent(klon, klev, klev)      real m(klon, klev), ment(klon, klev, klev), qent(klon, klev, klev)
153      real uent(klon, klev, klev), vent(klon, klev, klev)      real uent(klon, klev, klev), vent(klon, klev, klev)
154      real ments(klon, klev, klev), qents(klon, klev, klev)      real ments(klon, klev, klev), qents(klon, klev, klev)
155      real sij(klon, klev, klev), elij(klon, klev, klev)      real sij(klon, klev, klev), elij(klon, klev, klev)
156      real qp(klon, klev), up(klon, klev), vp(klon, klev)      real qp(klon, klev), up(klon, klev), vp(klon, klev)
157      real wt(klon, klev), water(klon, klev), evap(klon, klev)      real wt(klon, klev), water(klon, klev)
158      real b(klon, klev), ft(klon, klev), fq(klon, klev)      real, allocatable:: evap(:, :) ! (ncum, nl)
159        real, allocatable:: b(:, :) ! (ncum, nl - 1)
160        real ft(klon, klev), fq(klon, klev)
161      real fu(klon, klev), fv(klon, klev)      real fu(klon, klev), fv(klon, klev)
162      real upwd(klon, klev), dnwd(klon, klev), dnwd0(klon, klev)      real upwd(klon, klev), dnwd(klon, klev), dnwd0(klon, klev)
163      real Ma(klon, klev), mike(klon, klev), tls(klon, klev)      real Ma(klon, klev), mike(klon, klev), tls(klon, klev)
164      real tps(klon, klev), qprime(klon), tprime(klon)      real tps(klon, klev)
165      real precip(klon)      real precip(klon)
166      real VPrecip(klon, klev+1)      real VPrecip(klon, klev + 1)
167      real qcondc(klon, klev) ! cld      real qcondc(klon, klev) ! cld
     real wd(klon) ! gust  
168    
169      !-------------------------------------------------------------------      !-------------------------------------------------------------------
     ! --- SET CONSTANTS AND PARAMETERS  
   
     ! -- set simulation flags:  
     ! (common cvflag)  
   
     CALL cv_flag  
170    
171      ! -- set thermodynamical constants:      ! SET CONSTANTS AND PARAMETERS
     ! (common cvthermo)  
172    
173        ! set thermodynamical constants:
174      CALL cv_thermo      CALL cv_thermo
175    
176      ! -- set convect parameters      CALL cv30_param
177    
178      ! includes microphysical parameters and parameters that      ! INITIALIZE OUTPUT ARRAYS AND PARAMETERS
     ! control the rate of approach to quasi-equilibrium)  
     ! (common cvparam)  
   
     if (iflag_con == 3) CALL cv3_param(klev, delt)  
   
     ! --- INITIALIZE OUTPUT ARRAYS AND PARAMETERS  
179    
180      do k = 1, klev      do k = 1, klev
181         do i = 1, klon         do i = 1, klon
182            ft1(i, k) = 0.0            ft1(i, k) = 0.
183            fq1(i, k) = 0.0            fq1(i, k) = 0.
184            fu1(i, k) = 0.0            fu1(i, k) = 0.
185            fv1(i, k) = 0.0            fv1(i, k) = 0.
186            tvp1(i, k) = 0.0            tvp1(i, k) = 0.
187            tp1(i, k) = 0.0            tp1(i, k) = 0.
188            clw1(i, k) = 0.0            clw1(i, k) = 0.
189            !ym            clw(i, k) = 0.
           clw(i, k) = 0.0  
190            gz1(i, k) = 0.            gz1(i, k) = 0.
191            VPrecip1(i, k) = 0.            VPrecip1(i, k) = 0.
192            Ma1(i, k) = 0.0            Ma1(i, k) = 0.
193            upwd1(i, k) = 0.0            upwd1(i, k) = 0.
194            dnwd1(i, k) = 0.0            dnwd1(i, k) = 0.
195            dnwd01(i, k) = 0.0            dnwd01(i, k) = 0.
196            qcondc1(i, k) = 0.0            qcondc1(i, k) = 0.
197         end do         end do
198      end do      end do
199    
200      do i = 1, klon      precip1 = 0.
201         precip1(i) = 0.0      iflag1 = 0
202         iflag1(i) = 0      cape1 = 0.
203         wd1(i) = 0.0      VPrecip1(:, klev + 1) = 0.
204         cape1(i) = 0.0  
205         VPrecip1(i, klev+1) = 0.0      do il = 1, klon
206      end do         sig1(il, klev) = sig1(il, klev) + 1.
207           sig1(il, klev) = min(sig1(il, klev), 12.1)
208        enddo
209    
210        CALL cv30_prelim(klon, klev, klev + 1, t1, q1, p1, ph1, lv1, cpn1, tv1, &
211             gz1, h1, hm1, th1)
212        CALL cv30_feed(t1, q1, qs1, p1, ph1, gz1, nk1, icb1, icbmax, iflag1, &
213             tnk1, qnk1, gznk1, plcl1)
214        CALL cv30_undilute1(t1, q1, qs1, gz1, plcl1, p1, nk1, icb1, tp1, tvp1, &
215             clw1, icbs1)
216        CALL cv30_trigger(icb1, plcl1, p1, th1, tv1, tvp1, pbase1, buoybase1, &
217             iflag1, sig1, w01)
218    
219      if (iflag_con == 3) then      ! Moist convective adjustment is necessary
        do il = 1, klon  
           sig1(il, klev) = sig1(il, klev) + 1.  
           sig1(il, klev) = min(sig1(il, klev), 12.1)  
        enddo  
     endif  
   
     ! --- CALCULATE ARRAYS OF GEOPOTENTIAL, HEAT CAPACITY & STATIC ENERGY  
   
     if (iflag_con == 3) then  
        CALL cv3_prelim(klon, klev, klev + 1, t1, q1, p1, ph1, lv1, cpn1, tv1, &  
             gz1, h1, hm1, th1)  
     else  
        ! iflag_con == 4  
        CALL cv_prelim(klon, klev, klev + 1, t1, q1, p1, ph1, lv1, cpn1, tv1, &  
             gz1, h1, hm1)  
     endif  
   
     ! --- CONVECTIVE FEED  
   
     if (iflag_con == 3) then  
        CALL cv3_feed(klon, klev, t1, q1, qs1, p1, ph1, gz1, nk1, icb1, &  
             icbmax, iflag1, tnk1, qnk1, gznk1, plcl1) ! klev->na  
     else  
        ! iflag_con == 4  
        CALL cv_feed(klon, klev, t1, q1, qs1, p1, hm1, gz1, nk1, icb1, icbmax, &  
             iflag1, tnk1, qnk1, gznk1, plcl1)  
     endif  
   
     ! --- UNDILUTE (ADIABATIC) UPDRAFT / 1st part  
     ! (up through ICB for convect4, up through ICB+1 for convect3)  
     ! Calculates the lifted parcel virtual temperature at nk, the  
     ! actual temperature, and the adiabatic liquid water content.  
   
     if (iflag_con == 3) then  
        CALL cv3_undilute1(klon, klev, t1, q1, qs1, gz1, plcl1, p1, nk1, icb1, &  
             tp1, tvp1, clw1, icbs1) ! klev->na  
     else  
        ! iflag_con == 4  
        CALL cv_undilute1(klon, klev, t1, q1, qs1, gz1, p1, nk1, icb1, icbmax, &  
             tp1, tvp1, clw1)  
     endif  
   
     ! --- TRIGGERING  
   
     if (iflag_con == 3) then  
        CALL cv3_trigger(klon, klev, icb1, plcl1, p1, th1, tv1, tvp1, pbase1, &  
             buoybase1, iflag1, sig1, w01) ! klev->na  
     else  
        ! iflag_con == 4  
        CALL cv_trigger(klon, klev, icb1, cbmf1, tv1, tvp1, iflag1)  
     end if  
   
     ! --- IF THIS POINT IS REACHED, MOIST CONVECTIVE ADJUSTMENT IS NECESSARY  
220    
221      ncum = 0      ncum = 0
222      do i = 1, klon      do i = 1, klon
223         if(iflag1(i) == 0)then         if (iflag1(i) == 0) then
224            ncum = ncum+1            ncum = ncum + 1
225            idcum(ncum) = i            idcum(ncum) = i
226         endif         endif
227      end do      end do
228    
229      IF (ncum > 0) THEN      IF (ncum > 0) THEN
230         ! --- COMPRESS THE FIELDS         allocate(b(ncum, nl - 1), evap(ncum, nl), icb(ncum))
231         ! (-> vectorization over convective gridpoints)         CALL cv30_compress(ncum, iflag1, nk1, icb1, icbs1, plcl1, tnk1, qnk1, &
232                gznk1, pbase1, buoybase1, t1, q1, qs1, u1, v1, gz1, th1, h1, lv1, &
233         if (iflag_con == 3) then              cpn1, p1, ph1, tv1, tp1, tvp1, clw1, sig1, w01, iflag, nk, icb, &
234            CALL cv3_compress(klon, klon, ncum, klev, iflag1, nk1, icb1, icbs1, &              icbs, plcl, tnk, qnk, gznk, pbase, buoybase, t, q, qs, u, v, gz, &
235                 plcl1, tnk1, qnk1, gznk1, pbase1, buoybase1, t1, q1, qs1, u1, &              th, h, lv, cpn, p, ph, tv, tp, tvp, clw, sig, w0)
236                 v1, gz1, th1, h1, lv1, cpn1, p1, ph1, tv1, tp1, tvp1, clw1, &         CALL cv30_undilute2(icb, icbs(:ncum), nk, tnk, qnk, gznk, t, qs, gz, &
237                 sig1, w01, iflag, nk, icb, icbs, plcl, tnk, qnk, gznk, pbase, &              p, h, tv, lv, pbase, buoybase, plcl, inb(:ncum), tp, tvp, clw, &
238                 buoybase, t, q, qs, u, v, gz, th, h, lv, cpn, p, ph, tv, tp, &              hp, ep, buoy)
239                 tvp, clw, sig, w0)         CALL cv30_closure(icb, inb(:ncum), pbase, p, ph, tv, buoy, sig, w0, &
240         else              cape, m)
241            ! iflag_con == 4         CALL cv30_mixing(icb, nk(:ncum), inb(:ncum), t, q, qs, u, v, h, lv, &
242            CALL cv_compress(klon, klon, ncum, klev, iflag1, nk1, icb1, cbmf1, &              hp, ep, clw, m, sig, ment, qent, uent, vent, nent, sij, elij, &
243                 plcl1, tnk1, qnk1, gznk1, t1, q1, qs1, u1, v1, gz1, h1, lv1, &              ments, qents)
244                 cpn1, p1, ph1, tv1, tp1, tvp1, clw1, iflag, nk, icb, cbmf, &         CALL cv30_unsat(icb, inb(:ncum), t(:ncum, :nl), q(:ncum, :nl), &
245                 plcl, tnk, qnk, gznk, t, q, qs, u, v, gz, h, lv, cpn, p, ph, &              qs(:ncum, :nl), gz, u, v, p, ph, th(:ncum, :nl - 1), tv, lv, cpn, &
246                 tv, tp, tvp, clw, dph)              ep(:ncum, :), clw(:ncum, :), m(:ncum, :), ment(:ncum, :, :), &
247         endif              elij(:ncum, :, :), dtphys, plcl, mp, qp(:ncum, :nl), &
248                up(:ncum, :nl), vp(:ncum, :nl), wt(:ncum, :nl), &
249         ! --- UNDILUTE (ADIABATIC) UPDRAFT / second part :              water(:ncum, :nl), evap, b)
250         ! --- FIND THE REST OF THE LIFTED PARCEL TEMPERATURES         CALL cv30_yield(icb, inb(:ncum), dtphys, t, q, u, v, gz, p, ph, h, hp, &
251         ! --- &              lv, cpn, th, ep, clw, m, tp, mp, qp, up, vp(:ncum, 2:nl), &
252         ! --- COMPUTE THE PRECIPITATION EFFICIENCIES AND THE              wt(:ncum, :nl - 1), water(:ncum, :nl), evap, b, ment, qent, uent, &
253         ! --- FRACTION OF PRECIPITATION FALLING OUTSIDE OF CLOUD              vent, nent, elij, sig, tv, tvp, iflag, precip, VPrecip, ft, fq, &
254         ! --- &              fu, fv, upwd, dnwd, dnwd0, ma, mike, tls, tps, qcondc)
255         ! --- FIND THE LEVEL OF NEUTRAL BUOYANCY         CALL cv30_tracer(klon, ncum, klev, ment, sij, da, phi)
256    
257         if (iflag_con == 3) then         ! UNCOMPRESS THE FIELDS
258            CALL cv3_undilute2(klon, ncum, klev, icb, icbs, nk, tnk, qnk, gznk, &         iflag1 = 42 ! for non convective points
259                 t, q, qs, gz, p, h, tv, lv, pbase, buoybase, plcl, inb, tp, &         CALL cv30_uncompress(idcum(:ncum), iflag, precip, VPrecip, sig, w0, &
260                 tvp, clw, hp, ep, sigp, buoy) !na->klev              ft, fq, fu, fv, inb, Ma, upwd, dnwd, dnwd0, qcondc, cape, &
261         else              da, phi, mp, iflag1, precip1, VPrecip1, sig1, w01, ft1, fq1, &
262            ! iflag_con == 4              fu1, fv1, inb1, Ma1, upwd1, dnwd1, dnwd01, qcondc1, cape1, da1, &
263            CALL cv_undilute2(klon, ncum, klev, icb, nk, tnk, qnk, gznk, t, q, &              phi1, mp1)
264                 qs, gz, p, dph, h, tv, lv, inb, inbis, tp, tvp, clw, hp, ep, &      ENDIF
                sigp, frac)  
        endif  
   
        ! --- CLOSURE  
   
        if (iflag_con == 3) then  
           CALL cv3_closure(klon, ncum, klev, icb, inb, pbase, p, ph, tv, &  
                buoy, sig, w0, cape, m) ! na->klev  
        else  
           ! iflag_con == 4  
           CALL cv_closure(klon, ncum, klev, nk, icb, tv, tvp, p, ph, dph, &  
                plcl, cpn, iflag, cbmf)  
        endif  
   
        ! --- MIXING  
   
        if (iflag_con == 3) then  
           CALL cv3_mixing(klon, ncum, klev, klev, icb, nk, inb, t, q, qs, u, &  
                v, h, lv, hp, ep, clw, m, sig, ment, qent, uent, vent, nent, &  
                sij, elij, ments, qents)  
        else  
           ! iflag_con == 4  
           CALL cv_mixing(klon, ncum, klev, icb, nk, inb, inbis, ph, t, q, qs, &  
                u, v, h, lv, qnk, hp, tv, tvp, ep, clw, cbmf, m, ment, qent, &  
                uent, vent, nent, sij, elij)  
        endif  
   
        ! --- UNSATURATED (PRECIPITATING) DOWNDRAFTS  
   
        if (iflag_con == 3) then  
           CALL cv3_unsat(klon, ncum, klev, klev, icb, inb, t, q, qs, gz, u, &  
                v, p, ph, th, tv, lv, cpn, ep, sigp, clw, m, ment, elij, delt, &  
                plcl, mp, qp, up, vp, wt, water, evap, b)! na->klev  
        else  
           ! iflag_con == 4  
           CALL cv_unsat(klon, ncum, klev, inb, t, q, qs, gz, u, v, p, ph, h, &  
                lv, ep, sigp, clw, m, ment, elij, iflag, mp, qp, up, vp, wt, &  
                water, evap)  
        endif  
   
        ! --- YIELD  
        ! (tendencies, precipitation, variables of interface with other  
        ! processes, etc)  
   
        if (iflag_con == 3) then  
           CALL cv3_yield(klon, ncum, klev, klev, icb, inb, delt, t, q, u, v, &  
                gz, p, ph, h, hp, lv, cpn, th, ep, clw, m, tp, mp, qp, up, vp, &  
                wt, water, evap, b, ment, qent, uent, vent, nent, elij, sig, &  
                tv, tvp, iflag, precip, VPrecip, ft, fq, fu, fv, upwd, dnwd, &  
                dnwd0, ma, mike, tls, tps, qcondc, wd)! na->klev  
        else  
           ! iflag_con == 4  
           CALL cv_yield(klon, ncum, klev, nk, icb, inb, delt, t, q, u, v, gz, &  
                p, ph, h, hp, lv, cpn, ep, clw, frac, m, mp, qp, up, vp, wt, &  
                water, evap, ment, qent, uent, vent, nent, elij, tv, tvp, &  
                iflag, wd, qprime, tprime, precip, cbmf, ft, fq, fu, fv, Ma, &  
                qcondc)  
        endif  
   
        ! --- passive tracers  
   
        if (iflag_con == 3) CALL cv3_tracer(klon, ncum, klev, ment, sij, da, phi)  
   
        ! --- UNCOMPRESS THE FIELDS  
   
        ! set iflag1 = 42 for non convective points  
        do i = 1, klon  
           iflag1(i) = 42  
        end do  
   
        if (iflag_con == 3) then  
           CALL cv3_uncompress(idcum(:ncum), iflag, precip, VPrecip, sig, w0, &  
                ft, fq, fu, fv, inb, Ma, upwd, dnwd, dnwd0, qcondc, wd, cape, &  
                da, phi, mp, iflag1, precip1, VPrecip1, sig1, w01, ft1, fq1, &  
                fu1, fv1, inb1, Ma1, upwd1, dnwd1, dnwd01, qcondc1, wd1, &  
                cape1, da1, phi1, mp1)  
        else  
           ! iflag_con == 4  
           CALL cv_uncompress(idcum(:ncum), iflag, precip, cbmf, ft, fq, fu, &  
                fv, Ma, qcondc, iflag1, precip1, cbmf1, ft1, fq1, fu1, fv1, &  
                Ma1, qcondc1)  
        endif  
     ENDIF ! ncum>0  
265    
266    end SUBROUTINE cv_driver    end SUBROUTINE cv_driver
267    

Legend:
Removed from v.145  
changed lines
  Added in v.195

  ViewVC Help
Powered by ViewVC 1.1.21