/[lmdze]/trunk/src_test_ozonecm
ViewVC logotype

Log of /trunk/src_test_ozonecm

Parent Directory Parent Directory | Revision Log Revision Log


Sticky Revision:
(Current path doesn't exist after revision 333)

Revision 266 - (view) (annotate) - [select for diffs]
Modified Thu Apr 19 17:54:55 2018 UTC (6 years ago) by guez
File length: 188 byte(s)
Diff to previous 265
Define macros of the preprocessor CPP_IIM, CPP_JJM, CPP_LLM so we can
control the resolution from the compilation command, and automate
compilation for several resolutions.

In module yoethf_m, transform variables into named constants. So we do
not need procedure yoethf any longer.

Bug fix in program test_inter_barxy, missing calls to fyhyp and fxhyp,
and definition of rlatu.

Remove variable iecri of module conf_gcm_m. The files dyn_hist*.nc are
written every time step. We are simplifying the output system, pending
replacement by a whole new system.

Modify possible value of vert_sampling from "param" to
"strato_custom", following LMDZ. Default values of corresponding
namelist variables are now the values used for LMDZ CMIP6.


Revision 265 - (view) (annotate) - [select for diffs]
Modified Tue Mar 20 09:35:59 2018 UTC (6 years, 1 month ago) by guez
File length: 188 byte(s)
Diff to previous 191
Rename module dimens_m to dimensions.

Revision 191 - (view) (annotate) - [select for diffs]
Modified Mon May 9 19:56:28 2016 UTC (7 years, 11 months ago) by guez
File length: 186 byte(s)
Diff to previous 175
Extracted the call to read_comdissnew out of conf_gcm.

Made ok_instan a variable of module clesphys, itau_phy a variable of
module phyetat0_m, nid_ins a variable of module ini_histins_m, itap a
variable of new module time_phylmdz, so that histwrite_phy can be
called from any procedure without the need to cascade those variables
into that procedure. Made itau_w a variable of module time_phylmdz so
that it is computed only once per time step of physics.

Extracted variables of module clesphys which were in namelist
conf_phys_nml into their own namelist, clesphys_nml, and created
procedure read_clesphys reading clesphys_nml, to avoid side effect.

No need for double precision in procedure getso4fromfile. Assume there
is a single variable for the whole year in the NetCDF file instead of
one variable per month.

Created generic procedure histwrite_phy and removed procedure
write_histins, following LMDZ. histwrite_phy has only two arguments,
can be called from anywhere, and should manage the logic of writing or
not writing into various history files with various operations. So the
test on ok_instan goes inside histwrite_phy.

Test for raz_date in phyetat0 instead of physiq to avoid side effect.

Created procedure increment_itap to avoid side effect.

Removed unnecessary differences between procedures readsulfate and
readsulfate_pi.


Revision 175 - (view) (annotate) - [select for diffs]
Modified Fri Feb 5 16:02:34 2016 UTC (8 years, 2 months ago) by guez
File length: 91 byte(s)
Diff to previous 168
Added argument itau_phy to ini_histins, phyetat0, phytrac and
phyredem0. Removed variable itau_phy of module temps. Avoiding side
effect in etat0 and phyetat0. The procedures ini_histins, phyetat0,
phytrac and phyredem0 are all called by physiq so there is no
cascading variable penalty.

In procedure inifilr, made the condition on colat0 weaker to allow for
rounding error.

Removed arguments flux_o, flux_g and t_slab of clmain, flux_o and
flux_g of clqh and interfsurf_hq, tslab and seaice of phyetat0 and
phyredem. NetCDF variables TSLAB and SEAICE no longer in
restartphy.nc. All these variables were related to the not-implemented
slab ocean. seaice and tslab were just set to 0 in phyetat0 and never
used nor changed. flux_o and flux_g were computed in clmain but never
used in physiq.

Removed argument swnet of clqh. Was used only to compute a local
variable, swdown, which was not used.


Revision 168 - (view) (annotate) - [select for diffs]
Modified Wed Sep 9 10:41:47 2015 UTC (8 years, 7 months ago) by guez
File length: 99 byte(s)
Diff to previous 134
In order to be able to choose finer resolutions, set large memory
model in compiler options and use dynamic libraries.

Variables rlatd, rlond, cuphy and cvphy of module comgeomphy were
never used. (In LMDZ, they are used only for Orchid.)

There is a bug in PGI Fortran 13.10 that does not accept the
combination of forall, pack and spread in regr_pr_av and
regr_pr_int. In order to circumvent this bug, created the function
gr_dyn_phy.

In program test_inifilr, use a single latitude coordinate for north
and south.


Revision 134 - (view) (annotate) - [select for diffs]
Modified Wed Apr 29 15:47:56 2015 UTC (8 years, 11 months ago) by guez
File length: 87 byte(s)
Copied from: trunk/Compilation/src_test_ozonecm revision 133
Diff to previous 123
Sources inside, compilation outside.

Revision 123 - (view) (annotate) - [select for diffs]
Added Thu Feb 5 12:41:08 2015 UTC (9 years, 2 months ago) by guez
Original Path: trunk/Compilation/src_test_ozonecm
File length: 87 byte(s)
Added some test programs.

In fxhyp_loop_ik, changed precision from 1e-3 to 1e-6. Reset initial
value of xo1 to first guess of xi instead of final value of xi for
previous i (better logic).


This form allows you to request diffs between any two revisions of this file. For each of the two "sides" of the diff, enter a numeric revision.

  Diffs between and
  Type of Diff should be a

  ViewVC Help
Powered by ViewVC 1.1.21