- Timestamp:
- 12/16/16 10:06:51 (8 years ago)
- Location:
- CONFIG/UNIFORM/v6/IPSLCM6/EXPERIMENTS
- Files:
-
- 11 edited
Legend:
- Unmodified
- Added
- Removed
-
CONFIG/UNIFORM/v6/IPSLCM6/EXPERIMENTS/IPSLCM/pdControl/config.card
r3060 r3070 50 50 WriteFrequency="1M 1D" 51 51 # If config_Restarts_OverRule == 'n' next 4 params are read 52 Restart= n52 Restart= y 53 53 # Last day of the experience used as restart for this component if Restart=y 54 RestartDate= 1859-12-3154 RestartDate=2029-12-31 55 55 #D- Define restart simulation name for all components 56 RestartJobName= O1T09V0656 RestartJobName=CM606-LR-pdCtrl-01 57 57 #D- Path Server Group Login 58 RestartPath=/ccc/store/cont003/ dsm/p86mart/IGCM_OUT/IPSLCM6/DEVT/piControl58 RestartPath=/ccc/store/cont003/gencmip6/p86caub/IGCM_OUT/IPSLCM6/DEVT/pdControl 59 59 60 60 #======================================================================== … … 176 176 #D-- Post - 177 177 [Post] 178 ParserXIOS=FALSE 178 179 #D- Do we rebuild parallel output, this flag determines 179 180 #D- frequency of rebuild submission (use NONE for DRYRUN=3) … … 181 182 #D- Do we pack restart and debug txt files, this flag determines 182 183 #D- frequency of pack submission (use NONE for DRYRUN=3) 183 PackFrequency=1 Y184 PackFrequency=10Y 184 185 #D- If you want to produce time series, this flag determines 185 186 #D- frequency of post-processing submission (NONE if you dont want) 186 TimeSeriesFrequency=1 Y187 TimeSeriesFrequency=10Y 187 188 #D- If you want to produce seasonal average, this flag determines 188 189 #D- the period of this average (NONE if you dont want) -
CONFIG/UNIFORM/v6/IPSLCM6/EXPERIMENTS/IPSLCM/piControl/COMP/lmdz.card
r3032 r3070 10 10 # LMDZ_Physics=NPv5.70 for new physics to be used with LMDZ5/testing revision 2595 or later 11 11 # LMDZ_Physics=NPv5.80bz0 for new physics to be used with LMDZ5/trunk revision 2699 or later 12 LMDZ_Physics=NPv 5.80bz012 LMDZ_Physics=NPv6.0.7 13 13 14 14 # Set ConfType to choose parameters for aerosols, solar and green house gazes. … … 25 25 ok_aie=y 26 26 aerosol_couple=n 27 read_climoz= 227 read_climoz=1 28 28 ok_cdnc=y 29 29 … … 58 58 # With AR5 ozone(tropo + strato from LMDZOR-INCA-REPROBUS simulations) 59 59 ListNonDel= (${R_IN}/ATM/${RESOL_ATM}/AR5/HISTORIQUE/aerosols_11YearsClim_1855_v5.nc, aerosols.nat.nc),\ 60 (${R_IN}/ATM/ ${RESOL_ATM}/AR5/HISTORIQUE/climoz_LMDZ_1855_v2.nc, climoz_LMDZ.nc),\60 (${R_IN}/ATM/OZONE/UReading_2016/2D_14Fields/${RESOL_ATM_3D}/climoz_LMDZ_1850_1850_clim.nc, climoz_LMDZ.nc),\ 61 61 (${R_IN}/ATM/SOLAR/CMIP6/v3.1/Control/solarforcing_piControl_6bands_ave_1850-1873_365days.nc, solarforcing.nc),\ 62 62 (${R_IN}/ATM/STRATAERO/CMIP6/v1/${RESOL_ATM_XY}/L${RESOL_ATM_Z}/taulwstrat.2D.ave.nc, taulwstrat.2D.nc),\ -
CONFIG/UNIFORM/v6/IPSLCM6/EXPERIMENTS/IPSLCM/piControl/config.card
r3029 r3070 14 14 #----- DEVT TEST PROD 15 15 SpaceName=DEVT 16 LongName="IPSLCM6.0. 6"16 LongName="IPSLCM6.0.7" 17 17 TagName=IPSLCM6 18 18 #D- Choice of experiment in EXPERIMENTS directory … … 50 50 WriteFrequency="1M 1D" 51 51 # If config_Restarts_OverRule == 'n' next 4 params are read 52 Restart= n52 Restart= y 53 53 # Last day of the experience used as restart for this component if Restart=y 54 RestartDate= 1859-12-3154 RestartDate=2029-12-31 55 55 #D- Define restart simulation name for all components 56 RestartJobName= O1T09V0656 RestartJobName=CM606-LR-pdCtrl-01 57 57 #D- Path Server Group Login 58 RestartPath=/ccc/store/cont003/ dsm/p86mart/IGCM_OUT/IPSLCM6/DEVT/piControl58 RestartPath=/ccc/store/cont003/gencmip6/p86caub/IGCM_OUT/IPSLCM6/DEVT/pdControl 59 59 60 60 #======================================================================== … … 151 151 [ListOfComponents] 152 152 #D- For each component, Name of component, Tag of component 153 ATM= (lmdz, LMDZ-testing-r2 595)153 ATM= (lmdz, LMDZ-testing-r2729) 154 154 SRF= (orchidee, trunk-r3623) 155 155 SBG= (stomate, trunk-r3623) … … 176 176 #D-- Post - 177 177 [Post] 178 ParserXIOS=FALSE 178 179 #D- Do we rebuild parallel output, this flag determines 179 180 #D- frequency of rebuild submission (use NONE for DRYRUN=3) … … 181 182 #D- Do we pack restart and debug txt files, this flag determines 182 183 #D- frequency of pack submission (use NONE for DRYRUN=3) 183 PackFrequency=1 Y184 PackFrequency=10Y 184 185 #D- If you want to produce time series, this flag determines 185 186 #D- frequency of post-processing submission (NONE if you dont want) 186 TimeSeriesFrequency=1 Y187 TimeSeriesFrequency=10Y 187 188 #D- If you want to produce seasonal average, this flag determines 188 189 #D- the period of this average (NONE if you dont want) -
CONFIG/UNIFORM/v6/IPSLCM6/EXPERIMENTS/LMDZ/clim_360d/COMP/lmdz.card
r3057 r3070 10 10 # LMDZ_Physics=NPv5.70 for new physics to be used with LMDZ5/testing revision 2595 or later 11 11 # LMDZ_Physics=NPv5.80bz0 for new physics to be used with LMDZ5/trunk revision 2699 or later 12 LMDZ_Physics=NPv 5.80bz012 LMDZ_Physics=NPv6.0.7 13 13 14 14 # Set ConfType to choose parameters for aerosols, solar and green house gazes. … … 22 22 ok_aie=y 23 23 aerosol_couple=n 24 read_climoz= 224 read_climoz=1 25 25 ok_cdnc=y 26 26 … … 57 57 List=() 58 58 ListNonDel= (${R_IN}/ATM/LIMIT/AMIP.v20160609/interpol/${RESOL_ATM_XY}_eORCA1.2_360d/limit_1979_2008_clim.nc, limit.nc),\ 59 (${R_IN}/ATM/ ${RESOL_ATM}/AR5/HISTORIQUE/climoz_LMDZ_1995_v2.nc, climoz_LMDZ.nc),\59 (${R_IN}/ATM/OZONE/UReading_2016/2D_14Fields/${RESOL_ATM_3D}/climoz_LMDZ_1979_2008_clim.nc, climoz_LMDZ.nc),\ 60 60 (${R_IN}/ATM/${RESOL_ATM}/AR5/HISTORIQUE/aerosols_11YearsClim_1995_v5.nc, aerosols1980.nc),\ 61 61 (${R_IN}/ATM/${RESOL_ATM}/AR5/HISTORIQUE/aerosols_11YearsClim_1860_v5.nc, aerosols.nat.nc),\ -
CONFIG/UNIFORM/v6/IPSLCM6/EXPERIMENTS/LMDZ/clim_360d/config.card
r3039 r3070 63 63 WriteFrequency="1M" 64 64 # If config_Restarts_OverRule == 'n' next 4 params are read 65 Restart= n65 Restart= y 66 66 # Last day of the experience used as restart for this component if Restart=y 67 RestartDate=2000-01-31 68 # Define restart simulation name for this component 69 RestartJobName=LMDZ01 70 RestartPath=${ARCHIVE}/IGCM_OUT/LMDZ/DEVT/amip 67 RestartDate=2029-12-31 68 #D- Define restart simulation name for all components 69 RestartJobName=CM606-LR-pdCtrl-01 70 #D- Path Server Group Login 71 RestartPath=/ccc/store/cont003/gencmip6/p86caub/IGCM_OUT/IPSLCM6/DEVT/pdControl 71 72 72 73 #======================================================================== -
CONFIG/UNIFORM/v6/IPSLCM6/EXPERIMENTS/LMDZOR/amip/COMP/lmdz.card
r3057 r3070 10 10 # LMDZ_Physics=NPv5.70 for new physics to be used with LMDZ5/testing revision 2595 or later 11 11 # LMDZ_Physics=NPv5.80bz0 for new physics to be used with LMDZ5/trunk revision 2699 or later 12 LMDZ_Physics=NPv 5.80bz012 LMDZ_Physics=NPv6.0.7 13 13 14 14 # Set ConfType to choose parameters for aerosols, solar and green house gazes. … … 22 22 ok_aie=y 23 23 aerosol_couple=n 24 read_climoz= 224 read_climoz=1 25 25 ok_cdnc=y 26 26 … … 57 57 List= (${R_IN}/ATM/LIMIT/AMIP.v20160609/interpol/${RESOL_ATM_XY}_eORCA1.2_365d/limit_${year}.nc, limit.nc),\ 58 58 (${R_IN}/ATM/${RESOL_ATM}/AR5/HISTORIQUE/aerosols_11YearsClim_${year}_v5.nc, aerosols${year}.nc),\ 59 (${R_IN}/ATM/ ${RESOL_ATM}/AR5/HISTORIQUE/climoz_LMDZ_${year}_v2.nc,climoz_LMDZ.nc),\59 (${R_IN}/ATM/OZONE/UReading_2016/2D_14Fields/${RESOL_ATM_3D}/climoz_LMDZ_${year}.nc, climoz_LMDZ.nc),\ 60 60 (${R_IN}/ATM/SOLAR/CMIP6/v3.1/Historical/solarforcing_daily_3.1_6bands_${year}.nc, solarforcing.nc),\ 61 61 (${R_IN}/ATM/STRATAERO/CMIP6/v1/${RESOL_ATM_XY}/L${RESOL_ATM_Z}/taulwstrat.2D.${year}.nc, taulwstrat.2D.nc),\ -
CONFIG/UNIFORM/v6/IPSLCM6/EXPERIMENTS/LMDZOR/amip/config.card
r3039 r3070 67 67 WriteFrequency="1M" 68 68 # If config_Restarts_OverRule == 'n' next 4 params are read 69 Restart= n69 Restart= y 70 70 # Last day of the experience used as restart for this component if Restart=y 71 RestartDate=2000-01-31 72 # Define restart simulation name for this component 73 RestartJobName=LMDZOR01 74 RestartPath=${ARCHIVE}/IGCM_OUT/LMDZOR/DEVT/amip 71 RestartDate=2029-12-31 72 #D- Define restart simulation name for all components 73 RestartJobName=CM606-LR-pdCtrl-01 74 #D- Path Server Group Login 75 RestartPath=/ccc/store/cont003/gencmip6/p86caub/IGCM_OUT/IPSLCM6/DEVT/pdControl 75 76 76 77 #======================================================================== … … 116 117 RebuildFrequency=NONE 117 118 #D- PackFrequency determines the frequency of pack submission 118 PackFrequency=1 Y119 PackFrequency=10Y 119 120 #D- TimeSeriesFreqency determines the frequency of post-processing submission 120 121 #D- Set NONE to deactivate the creation of all time series -
CONFIG/UNIFORM/v6/IPSLCM6/EXPERIMENTS/LMDZOR/clim_360d/COMP/lmdz.card
r3057 r3070 10 10 # LMDZ_Physics=NPv5.70 for new physics to be used with LMDZ5/testing revision 2595 or later 11 11 # LMDZ_Physics=NPv5.80bz0 for new physics to be used with LMDZ5/trunk revision 2699 or later 12 LMDZ_Physics=NPv 5.80bz012 LMDZ_Physics=NPv6.0.7 13 13 14 14 # Set ConfType to choose parameters for aerosols, solar and green house gazes. … … 22 22 ok_aie=y 23 23 aerosol_couple=n 24 read_climoz= 224 read_climoz=1 25 25 ok_cdnc=y 26 26 … … 57 57 List=() 58 58 ListNonDel= (${R_IN}/ATM/LIMIT/AMIP.v20160609/interpol/${RESOL_ATM_XY}_eORCA1.2_360d/limit_1979_2008_clim.nc, limit.nc),\ 59 (${R_IN}/ATM/ ${RESOL_ATM}/AR5/HISTORIQUE/climoz_LMDZ_1995_v2.nc, climoz_LMDZ.nc),\59 (${R_IN}/ATM/OZONE/UReading_2016/2D_14Fields/${RESOL_ATM_3D}/climoz_LMDZ_1979_2008_clim.nc, climoz_LMDZ.nc),\ 60 60 (${R_IN}/ATM/${RESOL_ATM}/AR5/HISTORIQUE/aerosols_11YearsClim_1995_v5.nc, aerosols1980.nc),\ 61 61 (${R_IN}/ATM/${RESOL_ATM}/AR5/HISTORIQUE/aerosols_11YearsClim_1860_v5.nc, aerosols.nat.nc),\ -
CONFIG/UNIFORM/v6/IPSLCM6/EXPERIMENTS/LMDZOR/clim_360d/config.card
r3039 r3070 67 67 WriteFrequency="1M" 68 68 # If config_Restarts_OverRule == 'n' next 4 params are read 69 Restart= n69 Restart= y 70 70 # Last day of the experience used as restart for this component if Restart=y 71 RestartDate=2000-01-31 72 # Define restart simulation name for this component 73 RestartJobName=LMDZOR01 74 RestartPath=${ARCHIVE}/IGCM_OUT/LMDZOR/DEVT/amip 71 RestartDate=2029-12-31 72 #D- Define restart simulation name for all components 73 RestartJobName=CM606-LR-pdCtrl-01 74 #D- Path Server Group Login 75 RestartPath=/ccc/store/cont003/gencmip6/p86caub/IGCM_OUT/IPSLCM6/DEVT/pdControl 75 76 76 77 #======================================================================== -
CONFIG/UNIFORM/v6/IPSLCM6/EXPERIMENTS/LMDZOR/clim_pdControl/COMP/lmdz.card
r3043 r3070 10 10 # LMDZ_Physics=NPv5.70 for new physics to be used with LMDZ5/testing revision 2595 or later 11 11 # LMDZ_Physics=NPv5.80bz0 for new physics to be used with LMDZ5/trunk revision 2699 or later 12 LMDZ_Physics=NPv 5.80bz012 LMDZ_Physics=NPv6.0.7 13 13 14 14 # Set the variable CREATE needed further below to find the initial and boundary condition files. … … 26 26 ok_aie=y 27 27 aerosol_couple=n 28 read_climoz= 228 read_climoz=1 29 29 ok_cdnc=y 30 30 … … 63 63 (${R_IN}/ATM/${RESOL_ATM}/AR5/HISTORIQUE/aerosols_11YearsClim_1995_v5.nc, aerosols1980.nc),\ 64 64 (${R_IN}/ATM/LIMIT/AMIP.v20160609/interpol/${RESOL_ATM_XY}_eORCA1.2_365d/limit_1979_2008_clim.nc, limit.nc),\ 65 (${R_IN}/ATM/ ${RESOL_ATM}/AR5/HISTORIQUE/climoz_LMDZ_1995_v2.nc, climoz_LMDZ.nc),\65 (${R_IN}/ATM/OZONE/UReading_2016/2D_14Fields/${RESOL_ATM_3D}/climoz_LMDZ_1979_2008_clim.nc, climoz_LMDZ.nc),\ 66 66 (${R_IN}/ATM/SOLAR/CMIP6/v3.1/Control/solarforcing_pdControl_6bands_ave_1980-2000_365days.nc, solarforcing.nc),\ 67 67 (${R_IN}/ATM/STRATAERO/CMIP6/v1/${RESOL_ATM_XY}/L${RESOL_ATM_Z}/taulwstrat.2D.ave.nc, taulwstrat.2D.nc),\ -
CONFIG/UNIFORM/v6/IPSLCM6/EXPERIMENTS/LMDZOR/clim_pdControl/config.card
r3041 r3070 67 67 WriteFrequency="1M" 68 68 # If config_Restarts_OverRule == 'n' next 4 params are read 69 Restart= n69 Restart= y 70 70 # Last day of the experience used as restart for this component if Restart=y 71 RestartDate=2000-01-31 72 # Define restart simulation name for this component 73 RestartJobName=LMDZOR01 74 RestartPath=${ARCHIVE}/IGCM_OUT/LMDZOR/DEVT/amip 71 RestartDate=2029-12-31 72 #D- Define restart simulation name for all components 73 RestartJobName=CM606-LR-pdCtrl-01 74 #D- Path Server Group Login 75 RestartPath=/ccc/store/cont003/gencmip6/p86caub/IGCM_OUT/IPSLCM6/DEVT/pdControl 75 76 76 77 #========================================================================
Note: See TracChangeset
for help on using the changeset viewer.