Opened 8 years ago

Closed 7 years ago

#108 closed defect (fixed)

Reading data using an vertical axis change the axis distribution causing troubleshooting when reuse the axis to write data.e

Reported by: ymipsl Owned by: mhnguyen
Priority: major Component: XIOS
Version: 2.0 Keywords:
Cc:

Description


Change History (1)

comment:1 Changed 7 years ago by mhnguyen

  • Resolution set to fixed
  • Status changed from new to closed

There is a flag to verify if an axis is distributed. This flag isn't set correctly during reading data.
Corrected in r964

Note: See TracTickets for help on using tickets.