Opened 8 years ago
Closed 8 years ago
#92 closed enhancement (worksforme)
Using named constants in filters/operations
Reported by: | ssenesi | Owned by: | ymipsl |
---|---|---|---|
Priority: | minor | Component: | XIOS |
Version: | 2.0 | Keywords: | |
Cc: |
Description
Assume you want to convert an energy flux in mass flux using an XIOS filter :
<field id="tran" name="tran" unit="kg m-2 s-1"> evptr / 2.5008E+6</field>
It would be smarter to use (and re-use) a named constant, such as in :
<variable_definition> <variable id="coeffl" type="float">2.5008E+6</variable> </variable_definition> <field_definition id="field_definition" operation="instant" prec="4"> <field id="tran" name="tran" unit="kg m-2 s-1"> evptr / coeffl </field> </field_definition>
However, this does not work
Change History (3)
comment:1 Changed 8 years ago by rlacroix
comment:2 Changed 8 years ago by ssenesi
Yes, it works
Thanks Remi.
comment:3 Changed 8 years ago by rlacroix
- Resolution set to worksforme
- Status changed from new to closed
Note: See
TracTickets for help on using
tickets.
Hello Stephane,
Have you tried using $coeffl instead of just coeffl?
Best regards,
Rémi