New URL for NEMO forge!   http://forge.nemo-ocean.eu

Since March 2022 along with NEMO 4.2 release, the code development moved to a self-hosted GitLab.
This present forge is now archived and remained online for history.
trcini_fabm.F90 in branches/UKMO/AMM15_v3_6_STABLE_package_collate/NEMOGCM/NEMO/TOP_SRC/FABM – NEMO

source: branches/UKMO/AMM15_v3_6_STABLE_package_collate/NEMOGCM/NEMO/TOP_SRC/FABM/trcini_fabm.F90 @ 11545

Last change on this file since 11545 was 11545, checked in by dford, 5 years ago

Specify an index for the xEPS diagnostic from FABM, for use by the observation operator. See https://code.metoffice.gov.uk/trac/utils/ticket/247.

File size: 23.9 KB
Line 
1MODULE trcini_fabm
2   !!======================================================================
3   !!                         ***  MODULE trcini_fabm  ***
4   !! TOP :   initialisation of the FABM tracers
5   !!======================================================================
6   !! History :   2.0  !  2007-12  (C. Ethe, G. Madec) Original code
7   !!----------------------------------------------------------------------
8#if defined key_fabm
9   !!----------------------------------------------------------------------
10   !!   'key_fabm'                                               FABM tracers
11   !!----------------------------------------------------------------------
12   !! trc_ini_fabm   : FABM model initialisation
13   !!----------------------------------------------------------------------
14   USE par_trc         ! TOP parameters
15   USE oce_trc
16   USE trc
17   USE par_fabm
18   USE trcsms_fabm
19   USE fabm_config,ONLY: fabm_create_model_from_yaml_file
20   USE fabm,ONLY: type_external_variable, fabm_initialize_library
21   USE inputs_fabm,ONLY: initialize_inputs,link_inputs, &
22     type_input_variable,type_input_data,type_river_data, &
23     first_input_data,first_river_data
24#if defined key_git_version
25   USE fabm_version,ONLY: fabm_commit_id=>git_commit_id, &
26                          fabm_branch_name=>git_branch_name
27   USE fabm_types,ONLY: type_version,first_module_version
28#endif
29
30
31   IMPLICIT NONE
32   PRIVATE
33
34#if defined key_git_version
35!#include "gitversion.h90"
36   CHARACTER(len=*),parameter :: git_commit_id = _NEMO_COMMIT_ID_
37   CHARACTER(len=*),parameter :: git_branch_name = _NEMO_BRANCH_
38#endif
39
40   PUBLIC   trc_ini_fabm   ! called by trcini.F90 module
41   PUBLIC   nemo_fabm_init
42
43   !!----------------------------------------------------------------------
44   !! NEMO/TOP 3.3 , NEMO Consortium (2010)
45   !! $Id$
46   !! Software governed by the CeCILL licence     (NEMOGCM/NEMO_CeCILL.txt)
47   !!----------------------------------------------------------------------
48CONTAINS
49
50   SUBROUTINE nemo_fabm_init()
51      INTEGER :: jn
52      INTEGER, PARAMETER :: xml_unit = 1979
53      TYPE (type_input_data),POINTER :: input_data
54      TYPE (type_river_data),POINTER :: river_data
55      CLASS (type_input_variable),POINTER :: input_pointer
56
57      ! Allow FABM to parse fabm.yaml. This ensures numbers of variables are known.
58      call fabm_create_model_from_yaml_file(model)
59
60      jp_fabm = size(model%state_variables)
61      jp_fabm_bottom = size(model%bottom_state_variables)
62      jp_fabm_surface = size(model%surface_state_variables)
63      jp_fabm0 = jptra + 1
64      jp_fabm1 = jptra + jp_fabm
65      jp_fabm_m1=jptra
66      jptra = jptra + jp_fabm
67      jp_fabm_2d = size(model%horizontal_diagnostic_variables)
68      jp_fabm_3d = size(model%diagnostic_variables)
69      jpdia2d = jpdia2d + jp_fabm_2d
70      jpdia3d = jpdia3d + jp_fabm_3d
71      jpdiabio = jpdiabio + jp_fabm
72
73      !Initialize input data structures.
74      call initialize_inputs
75
76      ! Get indexes for select state variables
77      jp_fabm_chl1 = fabm_state_index( 'P1_Chl' )
78      jp_fabm_chl2 = fabm_state_index( 'P2_Chl' )
79      jp_fabm_chl3 = fabm_state_index( 'P3_Chl' )
80      jp_fabm_chl4 = fabm_state_index( 'P4_Chl' )
81      jp_fabm_p1c  = fabm_state_index( 'P1_c' )
82      jp_fabm_p1n  = fabm_state_index( 'P1_n' )
83      jp_fabm_p1p  = fabm_state_index( 'P1_p' )
84      jp_fabm_p1s  = fabm_state_index( 'P1_s' )
85      jp_fabm_p2c  = fabm_state_index( 'P2_c' )
86      jp_fabm_p2n  = fabm_state_index( 'P2_n' )
87      jp_fabm_p2p  = fabm_state_index( 'P2_p' )
88      jp_fabm_p3c  = fabm_state_index( 'P3_c' )
89      jp_fabm_p3n  = fabm_state_index( 'P3_n' )
90      jp_fabm_p3p  = fabm_state_index( 'P3_p' )
91      jp_fabm_p4c  = fabm_state_index( 'P4_c' )
92      jp_fabm_p4n  = fabm_state_index( 'P4_n' )
93      jp_fabm_p4p  = fabm_state_index( 'P4_p' )
94      jp_fabm_z4c  = fabm_state_index( 'Z4_c' )
95      jp_fabm_z5c  = fabm_state_index( 'Z5_c' )
96      jp_fabm_z5n  = fabm_state_index( 'Z5_n' )
97      jp_fabm_z5p  = fabm_state_index( 'Z5_p' )
98      jp_fabm_z6c  = fabm_state_index( 'Z6_c' )
99      jp_fabm_z6n  = fabm_state_index( 'Z6_n' )
100      jp_fabm_z6p  = fabm_state_index( 'Z6_p' )
101      jp_fabm_n1p  = fabm_state_index( 'N1_p' )
102      jp_fabm_n3n  = fabm_state_index( 'N3_n' )
103      jp_fabm_n4n  = fabm_state_index( 'N4_n' )
104      jp_fabm_n5s  = fabm_state_index( 'N5_s' )
105      jp_fabm_o2o  = fabm_state_index( 'O2_o' )
106      jp_fabm_o3c  = fabm_state_index( 'O3_c' )
107      jp_fabm_o3ba = fabm_state_index( 'O3_bioalk' )
108      jp_fabm_r4n  = fabm_state_index( 'R4_n' )
109      jp_fabm_r4c  = fabm_state_index( 'R4_c' )
110      jp_fabm_r4p  = fabm_state_index( 'R4_p' )
111      jp_fabm_r6n  = fabm_state_index( 'R6_n' )
112      jp_fabm_r6c  = fabm_state_index( 'R6_c' )
113      jp_fabm_r6p  = fabm_state_index( 'R6_p' )
114      jp_fabm_r6s  = fabm_state_index( 'R6_s' )
115      jp_fabm_r8n  = fabm_state_index( 'R8_n' )
116      jp_fabm_r8c  = fabm_state_index( 'R8_c' )
117      jp_fabm_r8p  = fabm_state_index( 'R8_p' )
118      jp_fabm_r8s  = fabm_state_index( 'R8_s' )
119
120      ! Get indexes for select diagnostic variables
121      jp_fabm_o3ta  = fabm_diag_index( 'O3_TA' )
122      jp_fabm_o3ph  = fabm_diag_index( 'O3_pH' )
123      jp_fabm_o3pc  = fabm_diag_index( 'O3_pCO2' )
124      jp_fabm_xeps  = fabm_diag_index( 'light_xEPS' )
125      jp_fabm_pgrow = fabm_diag_index( 'p_grow_sum_result' )
126      jp_fabm_ploss = fabm_diag_index( 'p_loss_sum_result' )
127     
128      MLD_MAX(:,:)   = 0.0
129      PGROW_AVG(:,:) = 0.0
130      PLOSS_AVG(:,:) = 0.0
131      PHYT_AVG(:,:)  = 0.0
132
133      IF (lwp) THEN
134         ! write field_def_fabm.xml on lead process
135         OPEN(UNIT=xml_unit,FILE='field_def_fabm.xml',ACTION='WRITE',STATUS='REPLACE')
136
137         WRITE (xml_unit,1000) '<field_definition level="1" prec="4" operation="average" enabled=".TRUE." default_value="1.e20" >'
138
139         WRITE (xml_unit,1000) ' <field_group id="ptrc_T" grid_ref="grid_T_3D">'
140         DO jn=1,jp_fabm
141            CALL write_variable_xml(xml_unit,model%state_variables(jn))
142#if defined key_trdtrc
143            CALL write_trends_xml(xml_unit,model%state_variables(jn))
144#endif
145            CALL write_25hourm_xml(xml_unit,model%state_variables(jn))
146            CALL write_tmb_xml(xml_unit,model%state_variables(jn))
147         END DO
148         WRITE (xml_unit,1000) ' </field_group>'
149
150         WRITE (xml_unit,1000) ' <field_group id="sf_T" grid_ref="grid_T_2D">'
151         DO jn=1,jp_fabm_surface
152            CALL write_variable_xml(xml_unit,model%surface_state_variables(jn))
153            CALL write_25hourm_xml(xml_unit,model%surface_state_variables(jn))
154         END DO
155         DO jn=1,jp_fabm_bottom
156            CALL write_variable_xml(xml_unit,model%bottom_state_variables(jn))
157            CALL write_25hourm_xml(xml_unit,model%bottom_state_variables(jn))
158         END DO
159         WRITE (xml_unit,1000) ' </field_group>'
160
161         WRITE (xml_unit,1000) ' <field_group id="diad_T" grid_ref="grid_T_2D">'
162         DO jn=1,size(model%diagnostic_variables)
163            CALL write_variable_xml(xml_unit,model%diagnostic_variables(jn),3)
164            CALL write_25hourm_xml(xml_unit,model%diagnostic_variables(jn),3)
165            CALL write_tmb_xml(xml_unit,model%diagnostic_variables(jn))
166         END DO
167         DO jn=1,size(model%horizontal_diagnostic_variables)
168            CALL write_variable_xml(xml_unit,model%horizontal_diagnostic_variables(jn))
169            CALL write_25hourm_xml(xml_unit,model%horizontal_diagnostic_variables(jn))
170         END DO
171         WRITE (xml_unit,1000) ' </field_group>'
172
173         WRITE (xml_unit,1000) ' <field_group id="fabm_scalar" grid_ref="grid_0">'
174         DO jn=1,size(model%conserved_quantities)
175            CALL write_variable_xml(xml_unit,model%conserved_quantities(jn))
176         END DO
177         WRITE (xml_unit,1000) ' </field_group>'
178
179         WRITE (xml_unit,1000) ' <field_group id="fabm_input" grid_ref="grid_T_2D">'
180         input_data => first_input_data
181         DO WHILE (ASSOCIATED(input_data))
182           input_pointer => input_data
183           CALL write_input_xml(xml_unit,input_pointer)
184            input_data => input_data%next
185         END DO
186         river_data => first_river_data
187         DO WHILE (ASSOCIATED(river_data))
188           input_pointer => river_data
189           CALL write_input_xml(xml_unit,input_pointer,3)
190            river_data => river_data%next
191         END DO
192         WRITE (xml_unit,1000) ' </field_group>'
193
194         WRITE (xml_unit,1000) '</field_definition>'
195
196         CLOSE(xml_unit)
197      END IF
198      IF( lk_mpp )   CALL mppsync !Ensure field_def_fabm is ready.
199
2001000 FORMAT (A)
201
202   END SUBROUTINE nemo_fabm_init
203
204   SUBROUTINE write_variable_xml(xml_unit,variable,flag_grid_ref)
205      INTEGER,INTENT(IN) :: xml_unit
206      INTEGER,INTENT(IN),OPTIONAL :: flag_grid_ref
207      CLASS (type_external_variable),INTENT(IN) :: variable
208
209      CHARACTER(LEN=20) :: missing_value,string_dimensions
210      INTEGER :: number_dimensions
211
212      ! Check variable dimension for grid_ref specificaiton.
213      ! Default is to not specify the grid_ref in the field definition.
214      IF (present(flag_grid_ref)) THEN
215          number_dimensions=flag_grid_ref
216      ELSE
217          number_dimensions=-1 !default, don't specify grid_ref
218      ENDIF
219
220      WRITE (missing_value,'(E9.3)') variable%missing_value
221      WRITE (string_dimensions,'(I1)') number_dimensions
222      SELECT CASE (number_dimensions)
223      CASE (3)
224         WRITE (xml_unit,'(A)') '  <field id="'//TRIM(variable%name)//'" long_name="'//TRIM(variable%long_name)//'" unit="'//TRIM(variable%units)//'" default_value="'//TRIM(ADJUSTL(missing_value))//'" grid_ref="grid_T_3D" />'
225      CASE (2)
226         WRITE (xml_unit,'(A)') '  <field id="'//TRIM(variable%name)//'" long_name="'//TRIM(variable%long_name)//'" unit="'//TRIM(variable%units)//'" default_value="'//TRIM(ADJUSTL(missing_value))//'" grid_ref="grid_T_2D"/>'
227      CASE (0)
228         WRITE (xml_unit,'(A)') '  <field id="'//TRIM(variable%name)//'" long_name="'//TRIM(variable%long_name)//'" unit="'//TRIM(variable%units)//'" default_value="'//TRIM(ADJUSTL(missing_value))//'" grid_ref="1point"/>'
229      CASE (-1)
230         WRITE (xml_unit,'(A)') '  <field id="'//TRIM(variable%name)//'" long_name="'//TRIM(variable%long_name)//'" unit="'//TRIM(variable%units)//'" default_value="'//TRIM(ADJUSTL(missing_value))//'" />'
231      CASE default
232         IF(lwp) WRITE(numout,*) ' trc_ini_fabm: Failing to initialise output of variable '//TRIM(variable%name)//': Output of '//TRIM(ADJUSTL(string_dimensions))//'-dimensional variables not supported!!!'
233      END SELECT
234
235   END SUBROUTINE write_variable_xml
236
237   SUBROUTINE write_25hourm_xml(xml_unit,variable,flag_grid_ref)
238      INTEGER,INTENT(IN) :: xml_unit
239      INTEGER,INTENT(IN),OPTIONAL :: flag_grid_ref
240      CLASS (type_external_variable),INTENT(IN) :: variable
241
242      CHARACTER(LEN=20) :: missing_value,string_dimensions
243      INTEGER :: number_dimensions
244
245      ! Check variable dimension for grid_ref specificaiton.
246      ! Default is to not specify the grid_ref in the field definition.
247      IF (present(flag_grid_ref)) THEN
248          number_dimensions=flag_grid_ref
249      ELSE
250          number_dimensions=-1 !default, don't specify grid_ref
251      ENDIF
252
253      WRITE (missing_value,'(E9.3)') 1.e+20
254      WRITE (string_dimensions,'(I1)') number_dimensions
255      SELECT CASE (number_dimensions)
256      CASE (3)
257         WRITE (xml_unit,'(A)') '  <field id="'//TRIM(variable%name)//'25h'//'" long_name="'//TRIM(variable%long_name)//' 25-hour mean'//'" unit="'//TRIM(variable%units)//'" default_value="'//TRIM(ADJUSTL(missing_value))//'" grid_ref="grid_T_3D" />'
258      CASE (2)
259         WRITE (xml_unit,'(A)') '  <field id="'//TRIM(variable%name)//'25h'//'" long_name="'//TRIM(variable%long_name)//' 25-hour mean'//'" unit="'//TRIM(variable%units)//'" default_value="'//TRIM(ADJUSTL(missing_value))//'" grid_ref="grid_T_2D"/>'
260      CASE (0)
261         WRITE (xml_unit,'(A)') '  <field id="'//TRIM(variable%name)//'25h'//'" long_name="'//TRIM(variable%long_name)//' 25-hour mean'//'" unit="'//TRIM(variable%units)//'" default_value="'//TRIM(ADJUSTL(missing_value))//'" grid_ref="1point"/>'
262      CASE (-1)
263         WRITE (xml_unit,'(A)') '  <field id="'//TRIM(variable%name)//'25h'//'" long_name="'//TRIM(variable%long_name)//' 25-hour mean'//'" unit="'//TRIM(variable%units)//'" default_value="'//TRIM(ADJUSTL(missing_value))//'" />'
264      CASE default
265         IF(lwp) WRITE(numout,*) ' trc_ini_fabm: Failing to initialise output of variable '//TRIM(variable%name)//'25h'//': Output of '//TRIM(ADJUSTL(string_dimensions))//'-dimensional variables not supported!!!'
266      END SELECT
267
268   END SUBROUTINE write_25hourm_xml
269
270   SUBROUTINE write_tmb_xml(xml_unit,variable)
271      INTEGER,INTENT(IN) :: xml_unit
272      CLASS (type_external_variable),INTENT(IN) :: variable
273
274      CHARACTER(LEN=20) :: missing_value
275
276      WRITE (missing_value,'(E9.3)') 1.e+20
277      WRITE (xml_unit,'(A)') '  <field id="top_'//TRIM(variable%name)//'" long_name="Top-level '//TRIM(variable%long_name)//'" unit="'//TRIM(variable%units)//'" default_value="'//TRIM(ADJUSTL(missing_value))//'" grid_ref="grid_T_2D"/>'
278      WRITE (xml_unit,'(A)') '  <field id="mid_'//TRIM(variable%name)//'" long_name="Middle-level '//TRIM(variable%long_name)//'" unit="'//TRIM(variable%units)//'" default_value="'//TRIM(ADJUSTL(missing_value))//'" grid_ref="grid_T_2D"/>'
279      WRITE (xml_unit,'(A)') '  <field id="bot_'//TRIM(variable%name)//'" long_name="Bottom-level '//TRIM(variable%long_name)//'" unit="'//TRIM(variable%units)//'" default_value="'//TRIM(ADJUSTL(missing_value))//'" grid_ref="grid_T_2D"/>'
280
281   END SUBROUTINE write_tmb_xml
282
283   SUBROUTINE write_trends_xml(xml_unit,variable,flag_grid_ref)
284      INTEGER,INTENT(IN) :: xml_unit
285      INTEGER,INTENT(IN),OPTIONAL :: flag_grid_ref
286      CLASS (type_external_variable),INTENT(IN) :: variable
287
288      INTEGER :: number_dimensions,i
289      CHARACTER(LEN=20) :: missing_value,string_dimensions
290#if defined key_tracer_budget
291      CHARACTER(LEN=3),DIMENSION(10),PARAMETER :: trd_tags = (/ &
292        'LDF','BBL','FOR','ZDF','DMP','SMS','ATF', &
293        'RDB','RDN','VMV' /)
294      CHARACTER(LEN=3),DIMENSION(3),PARAMETER :: trd_e3t_tags = (/ &
295        'XAD','YAD','ZAD' /)
296#else
297      CHARACTER(LEN=3),DIMENSION(13),PARAMETER :: trd_tags = (/ &
298        'XAD','YAD','ZAD','LDF','BBL','FOR','ZDF','DMP','SMS','ATF', &
299        'RDB','RDN','VMV' /)
300#endif
301
302      ! Check variable dimension for grid_ref specificaiton.
303      ! Default is to not specify the grid_ref in the field definition.
304      IF (present(flag_grid_ref)) THEN
305          number_dimensions=flag_grid_ref
306      ELSE
307          number_dimensions=-1 !default, don't specify grid_ref
308      ENDIF
309
310      WRITE (missing_value,'(E9.3)') -2.E20
311      WRITE (string_dimensions,'(I1)') number_dimensions
312      SELECT CASE (number_dimensions)
313      CASE (3)
314        DO i=1,size(trd_tags)
315         WRITE (xml_unit,'(A)') '  <field id="'//TRIM(trd_tags(i))//'_'//TRIM(variable%name)//'" long_name="'// &
316            &                   TRIM(variable%long_name)//' '//TRIM(trd_tags(i))//' trend" unit="'//            &
317            &                   TRIM(variable%units)//'/s" default_value="'//                                   &
318            &                   TRIM(ADJUSTL(missing_value))//'" grid_ref="grid_T_3D" />'
319        END DO
320#if defined key_tracer_budget
321        DO i=1,size(trd_e3t_tags)
322         WRITE (xml_unit,'(A)') '  <field id="'//TRIM(trd_e3t_tags(i))//'_'//TRIM(variable%name)//                     &
323            &                   '_e3t" long_name="'//TRIM(variable%long_name)//' cell depth integrated '//             &
324            &                   TRIM(trd_e3t_tags(i))//' trend" unit="'//TRIM(variable%units)//'/s" default_value="'// &
325            &                   TRIM(ADJUSTL(missing_value))//'" grid_ref="grid_T_3D" />'
326        END DO
327        WRITE (xml_unit,'(A)') '  <field id="'//TRIM(variable%name)//'_e3t" long_name="'//TRIM(variable%long_name)// &
328           &                   ' cell depth integrated" unit="'//TRIM(variable%units)//'/s" default_value="'//       &
329           &                   TRIM(ADJUSTL(missing_value))//'" grid_ref="grid_T_3D" />'
330#endif
331      CASE (-1)
332        DO i=1,size(trd_tags)
333         WRITE (xml_unit,'(A)') '  <field id="'//TRIM(trd_tags(i))//'_'//TRIM(variable%name)//'" long_name="'//   &
334            &                   TRIM(variable%long_name)//' '//TRIM(trd_tags(i))//' trend" unit="'//              &
335            &                   TRIM(variable%units)//'/s" default_value="'//TRIM(ADJUSTL(missing_value))//'" />'
336        END DO
337#if defined key_tracer_budget
338        DO i=1,size(trd_e3t_tags)
339         WRITE (xml_unit,'(A)') '  <field id="'//TRIM(trd_e3t_tags(i))//'_'//TRIM(variable%name)//                     &
340            &                   '_e3t" long_name="'//TRIM(variable%long_name)//' cell depth integrated '//             &
341            &                   TRIM(trd_e3t_tags(i))//' trend" unit="'//TRIM(variable%units)//'/s" default_value="'// &
342            &                   TRIM(ADJUSTL(missing_value))//'" />'
343        END DO
344        WRITE (xml_unit,'(A)') '  <field id="'//TRIM(variable%name)//'_e3t" long_name="'//TRIM(variable%long_name)// &
345           &                   ' cell depth integrated" unit="'//TRIM(variable%units)//'/s" default_value="'//       &
346           &                   TRIM(ADJUSTL(missing_value))//'" />'
347#endif
348      CASE default
349         IF(lwp) WRITE(numout,*) ' trc_ini_fabm: Failing to initialise trends of variable '//TRIM(variable%name)// &
350            &                    ': Output of '//TRIM(ADJUSTL(string_dimensions))//'-dimensional trends not supported!!!'
351      END SELECT
352
353   END SUBROUTINE write_trends_xml
354
355   SUBROUTINE write_input_xml(xml_unit,variable,flag_grid_ref)
356      INTEGER,INTENT(IN) :: xml_unit
357      INTEGER,INTENT(IN),OPTIONAL :: flag_grid_ref
358      CLASS(type_input_variable),POINTER,INTENT(IN) :: variable
359
360      INTEGER :: number_dimensions,i
361      CHARACTER(LEN=20) :: missing_value,string_dimensions
362
363      ! Check variable dimension for grid_ref specificaiton.
364      ! Default is to not specify the grid_ref in the field definition.
365      IF (present(flag_grid_ref)) THEN
366          number_dimensions=flag_grid_ref
367      ELSE
368          number_dimensions=-1 !default, don't specify grid_ref
369      ENDIF
370
371      WRITE (missing_value,'(E9.3)') -2.E20
372      WRITE (string_dimensions,'(I1)') number_dimensions
373      SELECT CASE (number_dimensions)
374      CASE (3)
375        WRITE (xml_unit,'(A)') '  <field id="'//'INP_'//TRIM(variable%sf(1)%clvar)//'" long_name="'//TRIM(variable%sf(1)%clvar)//' input" unit="" default_value="'//TRIM(ADJUSTL(missing_value))//'" grid_ref="grid_T_3D" />'
376      CASE (-1)
377        WRITE (xml_unit,'(A)') '  <field id="'//'INP_'//TRIM(variable%sf(1)%clvar)//'" long_name="'//TRIM(variable%sf(1)%clvar)//' input" unit="" default_value="'//TRIM(ADJUSTL(missing_value))//'" />'
378      CASE default
379         IF(lwp) WRITE(numout,*) ' trc_ini_fabm: Failing to initialise input diagnostic of variable '//TRIM(variable%sf(1)%clvar)//': Output of '//TRIM(ADJUSTL(string_dimensions))//'-dimensional diagnostic not supported!!!'
380      END SELECT
381
382   END SUBROUTINE write_input_xml
383
384   SUBROUTINE trc_ini_fabm
385      !!----------------------------------------------------------------------
386      !!                     ***  trc_ini_fabm  ***
387      !!
388      !! ** Purpose :   initialization for FABM model
389      !!
390      !! ** Method  : - Read the namcfc namelist and check the parameter values
391      !!----------------------------------------------------------------------
392#if defined key_git_version
393      TYPE (type_version),POINTER :: version
394#endif
395      INTEGER :: jn
396
397      !                       ! Allocate FABM arrays
398      IF( trc_sms_fabm_alloc() /= 0 )   CALL ctl_stop( 'STOP', 'trc_ini_fabm: unable to allocate FABM arrays' )
399
400      IF(lwp) WRITE(numout,*)
401      IF(lwp) WRITE(numout,*) ' trc_ini_fabm: initialisation of FABM model'
402      IF(lwp) WRITE(numout,*) ' ~~~~~~~~~~~~~~'
403#if defined key_git_version
404      IF(lwp) WRITE(numout,*) ' NEMO version:   ',git_commit_id,' (',git_branch_name,' branch)'
405      IF(lwp) WRITE(numout,*) ' FABM version:   ',fabm_commit_id,' (',fabm_branch_name,' branch)'
406#endif
407
408      call fabm_initialize_library()
409#if defined key_git_version
410      version => first_module_version
411
412      do while (associated(version))
413         IF(lwp) WRITE(numout,*)  ' '//trim(version%module_name)//' version:   ',trim(version%version_string)
414         version => version%next
415      end do
416#endif
417
418      ! Log mapping of FABM states:
419      IF (lwp) THEN
420         IF (jp_fabm.gt.0) WRITE(numout,*) " FABM tracers:"
421         DO jn=1,jp_fabm
422            WRITE(numout,*) "   State",jn,":",trim(model%state_variables(jn)%name), &
423               " (",trim(model%state_variables(jn)%long_name), &
424               ") [",trim(model%state_variables(jn)%units),"]"
425         ENDDO
426         IF (jp_fabm_surface.gt.0) WRITE(numout,*) "FABM seasurface states:"
427         DO jn=1,jp_fabm_surface
428            WRITE(numout,*) "   State",jn,":",trim(model%surface_state_variables(jn)%name), &
429               " (",trim(model%surface_state_variables(jn)%long_name), &
430               ") [",trim(model%surface_state_variables(jn)%units),"]"
431         ENDDO
432         IF (jp_fabm_bottom.gt.0) WRITE(numout,*) "FABM seafloor states:"
433         DO jn=1,jp_fabm_bottom
434            WRITE(numout,*) "   State",jn,":",trim(model%bottom_state_variables(jn)%name), &
435               " (",trim(model%bottom_state_variables(jn)%long_name), &
436               ") [",trim(model%bottom_state_variables(jn)%units),"]"
437         ENDDO
438      ENDIF
439
440   END SUBROUTINE trc_ini_fabm
441
442   INTEGER FUNCTION fabm_state_index( state_name )
443      !!----------------------------------------------------------------------
444      !!                     ***  fabm_state_index  *** 
445      !!
446      !! ** Purpose :   return index of a given FABM state variable
447      !!
448      !! ** Method  : - loop through state variables until found
449      !!----------------------------------------------------------------------
450     
451      IMPLICIT NONE
452     
453      CHARACTER(LEN=256), INTENT(IN) :: state_name
454     
455      INTEGER                        :: jn
456
457      !!----------------------------------------------------------------------
458     
459      fabm_state_index = -1
460      DO jn=1,jp_fabm
461         IF (TRIM(model%state_variables(jn)%name) == TRIM(state_name)) THEN
462            fabm_state_index = jn
463            EXIT
464         ENDIF
465      END DO
466      IF (fabm_state_index == -1) THEN
467         CALL ctl_warn( 'Could not find '//TRIM(state_name)//' state variable' )
468      ELSE
469         IF (lwp) WRITE(numout,*) 'Index for '//TRIM(state_name)//' is: ', fabm_state_index
470      ENDIF
471   
472   END FUNCTION fabm_state_index
473
474   INTEGER FUNCTION fabm_diag_index( diag_name )
475      !!----------------------------------------------------------------------
476      !!                     ***  fabm_state_index  *** 
477      !!
478      !! ** Purpose :   return index of a given FABM diagnostic variable
479      !!
480      !! ** Method  : - loop through diagnostic variables until found
481      !!----------------------------------------------------------------------
482     
483      IMPLICIT NONE
484     
485      CHARACTER(LEN=256), INTENT(IN) :: diag_name
486     
487      INTEGER                        :: jn
488
489      !!----------------------------------------------------------------------
490     
491      fabm_diag_index = -1
492      DO jn = 1, SIZE(model%diagnostic_variables)
493         IF (TRIM(model%diagnostic_variables(jn)%name) == TRIM(diag_name)) THEN
494            fabm_diag_index = jn
495            EXIT
496         ENDIF
497      END DO
498      IF (fabm_diag_index == -1) THEN
499         CALL ctl_warn( 'Could not find '//TRIM(diag_name)//' diagnostic' )
500      ELSE
501         IF (lwp) WRITE(numout,*) 'Index for '//TRIM(diag_name)//' is: ', fabm_diag_index
502      ENDIF
503   
504   END FUNCTION fabm_diag_index
505
506#else
507   !!----------------------------------------------------------------------
508   !!   Dummy module                                        No FABM model
509   !!----------------------------------------------------------------------
510CONTAINS
511   SUBROUTINE nemo_fabm_init
512   END SUBROUTINE nemo_fabm_init
513
514   SUBROUTINE trc_ini_fabm            ! Empty routine
515   END SUBROUTINE trc_ini_fabm
516#endif
517
518   !!======================================================================
519END MODULE trcini_fabm
Note: See TracBrowser for help on using the repository browser.