New URL for NEMO forge!   http://forge.nemo-ocean.eu

Since March 2022 along with NEMO 4.2 release, the code development moved to a self-hosted GitLab.
This present forge is now archived and remained online for history.
trabbc.F90 in branches/UKMO/r8395_mix-lyr_diag/NEMOGCM/NEMO/OPA_SRC/TRA – NEMO

source: branches/UKMO/r8395_mix-lyr_diag/NEMOGCM/NEMO/OPA_SRC/TRA/trabbc.F90 @ 11290

Last change on this file since 11290 was 11290, checked in by jcastill, 5 years ago

Remove svn keywords

File size: 9.3 KB
Line 
1MODULE trabbc
2   !!==============================================================================
3   !!                       ***  MODULE  trabbc  ***
4   !! Ocean active tracers:  bottom boundary condition (geothermal heat flux)
5   !!==============================================================================
6   !! History :  OPA  ! 1999-10 (G. Madec)  original code
7   !!   NEMO     1.0  ! 2002-08 (G. Madec)  free form + modules
8   !!             -   ! 2002-11 (A. Bozec)  tra_bbc_init: original code
9   !!            3.3  ! 2010-10 (G. Madec)  dynamical allocation + suppression of key_trabbc
10   !!             -   ! 2010-11 (G. Madec)  use mbkt array (deepest ocean t-level)
11   !!----------------------------------------------------------------------
12
13   !!----------------------------------------------------------------------
14   !!   tra_bbc       : update the tracer trend at ocean bottom
15   !!   tra_bbc_init  : initialization of geothermal heat flux trend
16   !!----------------------------------------------------------------------
17   USE oce            ! ocean variables
18   USE dom_oce        ! domain: ocean
19   USE phycst         ! physical constants
20   USE trd_oce        ! trends: ocean variables
21   USE trdtra         ! trends manager: tracers
22   !
23   USE in_out_manager ! I/O manager
24   USE iom            ! xIOS
25   USE fldread        ! read input fields
26   USE lbclnk         ! ocean lateral boundary conditions (or mpp link)
27   USE lib_mpp        ! distributed memory computing library
28   USE prtctl         ! Print control
29   USE wrk_nemo       ! Memory Allocation
30   USE timing         ! Timing
31
32   IMPLICIT NONE
33   PRIVATE
34
35   PUBLIC tra_bbc          ! routine called by step.F90
36   PUBLIC tra_bbc_init     ! routine called by opa.F90
37
38   !                                 !!* Namelist nambbc: bottom boundary condition *
39   LOGICAL, PUBLIC ::   ln_trabbc     !: Geothermal heat flux flag
40   INTEGER         ::   nn_geoflx     !  Geothermal flux (=1:constant flux, =2:read in file )
41   REAL(wp)        ::   rn_geoflx_cst !  Constant value of geothermal heat flux
42
43   REAL(wp), PUBLIC , ALLOCATABLE, DIMENSION(:,:) ::   qgh_trd0   ! geothermal heating trend
44
45   TYPE(FLD), ALLOCATABLE, DIMENSION(:) ::   sf_qgh   ! structure of input qgh (file informations, fields read)
46 
47   !!----------------------------------------------------------------------
48   !! NEMO/OPA 3.3 , NEMO Consortium (2010)
49   !! $Id$
50   !! Software governed by the CeCILL licence     (NEMOGCM/NEMO_CeCILL.txt)
51   !!----------------------------------------------------------------------
52CONTAINS
53
54   SUBROUTINE tra_bbc( kt )
55      !!----------------------------------------------------------------------
56      !!                  ***  ROUTINE tra_bbc  ***
57      !!
58      !! ** Purpose :   Compute the bottom boundary contition on temperature
59      !!              associated with geothermal heating and add it to the
60      !!              general trend of temperature equations.
61      !!
62      !! ** Method  :   The geothermal heat flux set to its constant value of
63      !!              86.4 mW/m2 (Stein and Stein 1992, Huang 1999).
64      !!       The temperature trend associated to this heat flux through the
65      !!       ocean bottom can be computed once and is added to the temperature
66      !!       trend juste above the bottom at each time step:
67      !!            ta = ta + Qsf / (rau0 rcp e3T) for k= mbkt
68      !!       Where Qsf is the geothermal heat flux.
69      !!
70      !! ** Action  : - update the temperature trends with geothermal heating trend
71      !!              - send the trend for further diagnostics (ln_trdtra=T)
72      !!
73      !! References : Stein, C. A., and S. Stein, 1992, Nature, 359, 123-129.
74      !!              Emile-Geay and Madec, 2009, Ocean Science.
75      !!----------------------------------------------------------------------
76      INTEGER, INTENT(in) ::   kt   ! ocean time-step index
77      !
78      INTEGER  ::   ji, jj    ! dummy loop indices
79      REAL(wp), POINTER, DIMENSION(:,:,:) ::   ztrdt
80      !!----------------------------------------------------------------------
81      !
82      IF( nn_timing == 1 )  CALL timing_start('tra_bbc')
83      !
84      IF( l_trdtra )   THEN         ! Save the input temperature trend
85         CALL wrk_alloc( jpi,jpj,jpk,   ztrdt )
86         ztrdt(:,:,:) = tsa(:,:,:,jp_tem)
87      ENDIF
88      !                             !  Add the geothermal trend on temperature
89      DO jj = 2, jpjm1
90         DO ji = 2, jpim1
91            tsa(ji,jj,mbkt(ji,jj),jp_tem) = tsa(ji,jj,mbkt(ji,jj),jp_tem) + qgh_trd0(ji,jj) / e3t_n(ji,jj,mbkt(ji,jj))
92         END DO
93      END DO
94      !
95      CALL lbc_lnk( tsa(:,:,:,jp_tem) , 'T', 1. )
96      !
97      IF( l_trdtra ) THEN        ! Send the trend for diagnostics
98         ztrdt(:,:,:) = tsa(:,:,:,jp_tem) - ztrdt(:,:,:)
99         CALL trd_tra( kt, 'TRA', jp_tem, jptra_bbc, ztrdt )
100         CALL wrk_dealloc( jpi,jpj,jpk,   ztrdt )
101      ENDIF
102      !
103      IF(ln_ctl)   CALL prt_ctl( tab3d_1=tsa(:,:,:,jp_tem), clinfo1=' bbc  - Ta: ', mask1=tmask, clinfo3='tra-ta' )
104      !
105      IF( nn_timing == 1 )  CALL timing_stop('tra_bbc')
106      !
107   END SUBROUTINE tra_bbc
108
109
110   SUBROUTINE tra_bbc_init
111      !!----------------------------------------------------------------------
112      !!                  ***  ROUTINE tra_bbc_init  ***
113      !!
114      !! ** Purpose :   Compute once for all the trend associated with geothermal
115      !!              heating that will be applied at each time step at the
116      !!              last ocean level
117      !!
118      !! ** Method  :   Read the nambbc namelist and check the parameters.
119      !!
120      !! ** Input   : - Namlist nambbc
121      !!              - NetCDF file  : geothermal_heating.nc ( if necessary )
122      !!
123      !! ** Action  : - read/fix the geothermal heat qgh_trd0
124      !!----------------------------------------------------------------------
125      INTEGER  ::   ji, jj              ! dummy loop indices
126      INTEGER  ::   inum                ! temporary logical unit
127      INTEGER  ::   ios                 ! Local integer output status for namelist read
128      INTEGER  ::   ierror              ! local integer
129      !
130      TYPE(FLD_N)        ::   sn_qgh    ! informations about the geotherm. field to be read
131      CHARACTER(len=256) ::   cn_dir    ! Root directory for location of ssr files
132      !
133      NAMELIST/nambbc/ln_trabbc, nn_geoflx, rn_geoflx_cst, sn_qgh, cn_dir 
134      !!----------------------------------------------------------------------
135      !
136      REWIND( numnam_ref )              ! Namelist nambbc in reference namelist : Bottom momentum boundary condition
137      READ  ( numnam_ref, nambbc, IOSTAT = ios, ERR = 901)
138901   IF( ios /= 0 )   CALL ctl_nam ( ios , 'nambbc in reference namelist', lwp )
139      !
140      REWIND( numnam_cfg )              ! Namelist nambbc in configuration namelist : Bottom momentum boundary condition
141      READ  ( numnam_cfg, nambbc, IOSTAT = ios, ERR = 902 )
142902   IF( ios /= 0 )   CALL ctl_nam ( ios , 'nambbc in configuration namelist', lwp )
143      IF(lwm) WRITE ( numond, nambbc )
144      !
145      IF(lwp) THEN                     ! Control print
146         WRITE(numout,*)
147         WRITE(numout,*) 'tra_bbc : Bottom Boundary Condition (bbc), apply a Geothermal heating'
148         WRITE(numout,*) '~~~~~~~   '
149         WRITE(numout,*) '   Namelist nambbc : set bbc parameters'
150         WRITE(numout,*) '      Apply a geothermal heating at ocean bottom   ln_trabbc     = ', ln_trabbc
151         WRITE(numout,*) '      type of geothermal flux                      nn_geoflx     = ', nn_geoflx
152         WRITE(numout,*) '      Constant geothermal flux value               rn_geoflx_cst = ', rn_geoflx_cst
153         WRITE(numout,*)
154      ENDIF
155      !
156      IF( ln_trabbc ) THEN             !==  geothermal heating  ==!
157         !
158         ALLOCATE( qgh_trd0(jpi,jpj) )    ! allocation
159         !
160         SELECT CASE ( nn_geoflx )        ! geothermal heat flux / (rauO * Cp)
161         !
162         CASE ( 1 )                          !* constant flux
163            IF(lwp) WRITE(numout,*) '      *** constant heat flux  =   ', rn_geoflx_cst
164            qgh_trd0(:,:) = r1_rau0_rcp * rn_geoflx_cst
165            !
166         CASE ( 2 )                          !* variable geothermal heat flux : read the geothermal fluxes in mW/m2
167            IF(lwp) WRITE(numout,*) '      *** variable geothermal heat flux'
168            !
169            ALLOCATE( sf_qgh(1), STAT=ierror )
170            IF( ierror > 0 ) THEN
171               CALL ctl_stop( 'tra_bbc_init: unable to allocate sf_qgh structure' )   ;
172               RETURN
173            ENDIF
174            ALLOCATE( sf_qgh(1)%fnow(jpi,jpj,1)   )
175            IF( sn_qgh%ln_tint )ALLOCATE( sf_qgh(1)%fdta(jpi,jpj,1,2) )
176            ! fill sf_chl with sn_chl and control print
177            CALL fld_fill( sf_qgh, (/ sn_qgh /), cn_dir, 'tra_bbc_init',   &
178               &          'bottom temperature boundary condition', 'nambbc', no_print )
179
180            CALL fld_read( nit000, 1, sf_qgh )                         ! Read qgh data
181            qgh_trd0(:,:) = r1_rau0_rcp * sf_qgh(1)%fnow(:,:,1) * 1.e-3 ! conversion in W/m2
182            !
183         CASE DEFAULT
184            WRITE(ctmp1,*) '     bad flag value for nn_geoflx = ', nn_geoflx
185            CALL ctl_stop( ctmp1 )
186         END SELECT
187         !
188      ELSE
189         IF(lwp) WRITE(numout,*) '      *** no geothermal heat flux'
190      ENDIF
191      !
192   END SUBROUTINE tra_bbc_init
193
194   !!======================================================================
195END MODULE trabbc
Note: See TracBrowser for help on using the repository browser.