New URL for NEMO forge!   http://forge.nemo-ocean.eu

Since March 2022 along with NEMO 4.2 release, the code development moved to a self-hosted GitLab.
This present forge is now archived and remained online for history.
Changeset 12396 for NEMO/trunk – NEMO

Changeset 12396 for NEMO/trunk


Ignore:
Timestamp:
2020-02-18T11:24:16+01:00 (4 years ago)
Author:
clem
Message:

correct heat diffusion in the ice in case of Jules coupling (Met Office), and add a small improvement when reading ice temperature with bdy

Location:
NEMO/trunk/src
Files:
3 edited

Legend:

Unmodified
Added
Removed
  • NEMO/trunk/src/ICE/icethd_zdf_bl99.F90

    r10926 r12396  
    769769      ! 
    770770      ! --- calculate conduction fluxes (positive downward) 
    771  
     771      !     bottom ice conduction flux 
    772772      DO ji = 1, npti 
    773          !                                ! surface ice conduction flux 
    774          qcn_ice_top_1d(ji) =  -           isnow(ji)   * zkappa_s(ji,0)      * zg1s * ( t_s_1d(ji,1) - t_su_1d(ji) )  & 
    775             &                  - ( 1._wp - isnow(ji) ) * zkappa_i(ji,0)      * zg1  * ( t_i_1d(ji,1) - t_su_1d(ji) ) 
    776          !                                ! bottom ice conduction flux 
    777          qcn_ice_bot_1d(ji) =                          - zkappa_i(ji,nlay_i) * zg1  * ( t_bo_1d(ji ) - t_i_1d (ji,nlay_i) ) 
     773         qcn_ice_bot_1d(ji) = - zkappa_i(ji,nlay_i) * zg1  * ( t_bo_1d(ji ) - t_i_1d (ji,nlay_i) ) 
    778774      END DO 
    779        
     775      !     surface ice conduction flux 
     776      IF( k_cnd == np_cnd_OFF .OR. k_cnd == np_cnd_EMU ) THEN 
     777         ! 
     778         DO ji = 1, npti 
     779            qcn_ice_top_1d(ji) =  -           isnow(ji)   * zkappa_s(ji,0) * zg1s * ( t_s_1d(ji,1) - t_su_1d(ji) )  & 
     780               &                  - ( 1._wp - isnow(ji) ) * zkappa_i(ji,0) * zg1  * ( t_i_1d(ji,1) - t_su_1d(ji) ) 
     781         END DO 
     782         ! 
     783      ELSEIF( k_cnd == np_cnd_ON ) THEN 
     784         ! 
     785         DO ji = 1, npti 
     786            qcn_ice_top_1d(ji) = qcn_ice_1d(ji) 
     787         END DO 
     788         ! 
     789      ENDIF 
     790      !     surface ice temperature 
     791      IF( k_cnd == np_cnd_ON .AND. ln_cndemulate ) THEN 
     792         ! 
     793         DO ji = 1, npti 
     794            t_su_1d(ji) = (  qcn_ice_top_1d(ji) &            ! calculate surface temperature 
     795               &           +           isnow(ji)   * zkappa_s(ji,0) * zg1s * t_s_1d(ji,1) & 
     796               &           + ( 1._wp - isnow(ji) ) * zkappa_i(ji,0) * zg1  * t_i_1d(ji,1) & 
     797               &          ) / MAX( epsi10, isnow(ji) * zkappa_s(ji,0) * zg1s + ( 1._wp - isnow(ji) ) * zkappa_i(ji,0) * zg1 ) 
     798            t_su_1d(ji) = MAX( MIN( t_su_1d(ji), rt0 ), rt0 - 100._wp )  ! cap t_su 
     799         END DO 
     800         ! 
     801      ENDIF 
    780802      ! 
    781803      ! --- Diagnose the heat loss due to changing non-solar / conduction flux --- ! 
     
    787809         END DO 
    788810         ! 
    789       ELSEIF( k_cnd == np_cnd_ON ) THEN 
    790          ! 
    791          DO ji = 1, npti 
    792             hfx_err_dif_1d(ji) = hfx_err_dif_1d(ji) - ( qcn_ice_top_1d(ji) - qcn_ice_1d(ji) ) * a_i_1d(ji)  
    793          END DO 
    794          ! 
    795811      ENDIF 
    796        
    797812      ! 
    798813      ! --- Diagnose the heat loss due to non-fully converged temperature solution (should not be above 10-4 W-m2) --- ! 
     
    856871         t_i_1d    (1:npti,:) = ztiold        (1:npti,:) 
    857872         qcn_ice_1d(1:npti)   = qcn_ice_top_1d(1:npti) 
    858  
    859          !!clem 
    860          ! remettre t_su_1d, qns_ice_1d et dqns_ice_1d comme avant puisqu'on devrait faire comme si on avant conduction = input 
    861          !clem 
    862873      ENDIF 
    863874      ! 
  • NEMO/trunk/src/OCE/BDY/bdydta.F90

    r12377 r12396  
    292292               &                                                                         bf_alias(jp_bdya_i)%fnow(:,1,:)     !   ( a_ip = rice_apnd * a_i ) 
    293293            IF( TRIM(bf_alias(jp_bdyhip)%clrootname) == 'NOT USED' )   bf_alias(jp_bdyhip)%fnow(:,1,:) = rice_hpnd(jbdy) 
     294             
     295            ! if T_i is read and not T_su, set T_su = T_i 
     296            IF( TRIM(bf_alias(jp_bdyt_i)%clrootname) /= 'NOT USED' .AND. TRIM(bf_alias(jp_bdytsu)%clrootname) == 'NOT USED' ) & 
     297               &   bf_alias(jp_bdytsu)%fnow(:,1,:) = bf_alias(jp_bdyt_i)%fnow(:,1,:) 
     298            ! if T_s is read and not T_su, set T_su = T_s 
     299            IF( TRIM(bf_alias(jp_bdyt_s)%clrootname) /= 'NOT USED' .AND. TRIM(bf_alias(jp_bdytsu)%clrootname) == 'NOT USED' ) & 
     300               &   bf_alias(jp_bdytsu)%fnow(:,1,:) = bf_alias(jp_bdyt_s)%fnow(:,1,:) 
     301            ! if T_i is read and not T_s, set T_s = T_i 
     302            IF( TRIM(bf_alias(jp_bdyt_i)%clrootname) /= 'NOT USED' .AND. TRIM(bf_alias(jp_bdyt_s)%clrootname) == 'NOT USED' ) & 
     303               &   bf_alias(jp_bdyt_s)%fnow(:,1,:) = bf_alias(jp_bdyt_i)%fnow(:,1,:) 
     304            ! if T_su is read and not T_s, set T_s = T_su 
     305            IF( TRIM(bf_alias(jp_bdytsu)%clrootname) /= 'NOT USED' .AND. TRIM(bf_alias(jp_bdyt_s)%clrootname) == 'NOT USED' ) & 
     306               &   bf_alias(jp_bdyt_s)%fnow(:,1,:) = bf_alias(jp_bdytsu)%fnow(:,1,:) 
    294307            ! if T_su is read and not T_i, set T_i = (T_su + T_freeze)/2 
    295308            IF( TRIM(bf_alias(jp_bdytsu)%clrootname) /= 'NOT USED' .AND. TRIM(bf_alias(jp_bdyt_i)%clrootname) == 'NOT USED' ) & 
    296309               &   bf_alias(jp_bdyt_i)%fnow(:,1,:) = 0.5_wp * ( bf_alias(jp_bdytsu)%fnow(:,1,:) + 271.15 ) 
    297             ! if T_su is read and not T_s, set T_s = T_su 
    298             IF( TRIM(bf_alias(jp_bdytsu)%clrootname) /= 'NOT USED' .AND. TRIM(bf_alias(jp_bdyt_s)%clrootname) == 'NOT USED' ) & 
    299                &   bf_alias(jp_bdyt_s)%fnow(:,1,:) = bf_alias(jp_bdytsu)%fnow(:,1,:) 
    300             ! if T_s is read and not T_su, set T_su = T_s 
    301             IF( TRIM(bf_alias(jp_bdyt_s)%clrootname) /= 'NOT USED' .AND. TRIM(bf_alias(jp_bdytsu)%clrootname) == 'NOT USED' ) & 
    302                &   bf_alias(jp_bdytsu)%fnow(:,1,:) = bf_alias(jp_bdyt_s)%fnow(:,1,:) 
    303310            ! if T_s is read and not T_i, set T_i = (T_s + T_freeze)/2 
    304311            IF( TRIM(bf_alias(jp_bdyt_s)%clrootname) /= 'NOT USED' .AND. TRIM(bf_alias(jp_bdyt_i)%clrootname) == 'NOT USED' ) & 
  • NEMO/trunk/src/OCE/SBC/sbc_ice.F90

    r10425 r12396  
    7070   REAL(wp), PUBLIC, ALLOCATABLE, SAVE, DIMENSION(:,:)   ::   wndm_ice       !: wind speed module at T-point                 [m/s] 
    7171   REAL(wp), PUBLIC, ALLOCATABLE, SAVE, DIMENSION(:,:)   ::   sstfrz         !: wind speed module at T-point                 [m/s] 
    72    REAL(wp), PUBLIC, ALLOCATABLE, SAVE, DIMENSION(:,:,:) ::   tsfc_ice       !: sea ice surface skin temperature (on categories) 
    7372#endif 
    7473 
     
    132131         &      qemp_ice(jpi,jpj)     , qevap_ice(jpi,jpj,jpl) , qemp_oce   (jpi,jpj)     ,   & 
    133132         &      qns_oce (jpi,jpj)     , qsr_oce  (jpi,jpj)     , emp_oce    (jpi,jpj)     ,   & 
    134          &      emp_ice (jpi,jpj)     , tsfc_ice (jpi,jpj,jpl) , sstfrz     (jpi,jpj)     , STAT= ierr(2) ) 
     133         &      emp_ice (jpi,jpj)     , sstfrz   (jpi,jpj)     , STAT= ierr(2) ) 
    135134#endif 
    136135 
Note: See TracChangeset for help on using the changeset viewer.