Changeset 12724 for NEMO/branches/2020/dev_r12377_KERNEL-06_techene_e3/src/OCE/SBC/sbcblk_algo_ncar.F90
- Timestamp:
- 2020-04-08T21:37:59+02:00 (4 years ago)
- Location:
- NEMO/branches/2020/dev_r12377_KERNEL-06_techene_e3
- Files:
-
- 2 edited
Legend:
- Unmodified
- Added
- Removed
-
NEMO/branches/2020/dev_r12377_KERNEL-06_techene_e3
- Property svn:externals
-
old new 3 3 ^/utils/build/mk@HEAD mk 4 4 ^/utils/tools@HEAD tools 5 ^/vendors/AGRIF/dev _r11615_ENHANCE-04_namelists_as_internalfiles_agrif@HEAD ext/AGRIF5 ^/vendors/AGRIF/dev@HEAD ext/AGRIF 6 6 ^/vendors/FCM@HEAD ext/FCM 7 7 ^/vendors/IOIPSL@HEAD ext/IOIPSL 8 9 # SETTE 10 ^/utils/CI/sette@HEAD sette
-
- Property svn:externals
-
NEMO/branches/2020/dev_r12377_KERNEL-06_techene_e3/src/OCE/SBC/sbcblk_algo_ncar.F90
r12377 r12724 112 112 REAL(wp), DIMENSION(jpi,jpj) :: stab ! stability test integer 113 113 !!---------------------------------------------------------------------------------- 114 ! 115 l_zt_equal_zu = .FALSE. 116 IF( ABS(zu - zt) < 0.01_wp ) l_zt_equal_zu = .TRUE. ! testing "zu == zt" is risky with double precision 114 l_zt_equal_zu = ( ABS(zu - zt) < 0.01_wp ) ! testing "zu == zt" is risky with double precision 117 115 118 116 U_blk = MAX( 0.5_wp , U_zu ) ! relative wind speed at zu (normally 10m), we don't want to fall under 0.5 m/s … … 143 141 ENDIF 144 142 145 !! Initializing values at z_u with z_t values: 146 t_zu = t_zt ; q_zu = q_zt 143 !! First guess of temperature and humidity at height zu: 144 t_zu = MAX( t_zt , 180._wp ) ! who knows what's given on masked-continental regions... 145 q_zu = MAX( q_zt , 1.e-6_wp ) ! " 147 146 148 147 !! ITERATION BLOCK
Note: See TracChangeset