- Timestamp:
- 2020-07-01T15:42:06+02:00 (4 years ago)
- Location:
- NEMO/branches/2020/dev_r12377_KERNEL-06_techene_e3
- Files:
-
- 2 edited
Legend:
- Unmodified
- Added
- Removed
-
NEMO/branches/2020/dev_r12377_KERNEL-06_techene_e3
- Property svn:externals
-
old new 8 8 9 9 # SETTE 10 ^/utils/CI/sette@ HEADsette10 ^/utils/CI/sette@12931 sette
-
- Property svn:externals
-
NEMO/branches/2020/dev_r12377_KERNEL-06_techene_e3/cfgs/SHARED/namelist_ref
r12724 r13193 1134 1134 ! ! = 3 as =2 with distinct dissipative an mixing length scale 1135 1135 ln_mxl0 = .true. ! surface mixing length scale = F(wind stress) (T) or not (F) 1136 nn_mxlice = 0 ! type of scaling under sea-ice 1137 ! = 0 no scaling under sea-ice 1138 ! = 1 scaling with constant sea-ice thickness 1139 ! = 2 scaling with mean sea-ice thickness ( only with SI3 sea-ice model ) 1140 ! = 3 scaling with maximum sea-ice thickness 1141 rn_mxlice = 10. ! max constant ice thickness value when scaling under sea-ice ( nn_mxlice=1) 1136 1142 rn_mxl0 = 0.04 ! surface buoyancy lenght scale minimum value 1137 1143 ln_drg = .false. ! top/bottom friction added as boundary condition of TKE … … 1394 1400 &namctl ! Control prints (default: OFF) 1395 1401 !----------------------------------------------------------------------- 1396 sn_cfctl%l_glochk = .FALSE. ! Range sanity checks are local (F) or global (T). Set T for debugging only 1397 sn_cfctl%l_allon = .FALSE. ! IF T activate all options. If F deactivate all unless l_config is T 1398 sn_cfctl%l_config = .TRUE. ! IF .true. then control which reports are written with the following 1399 sn_cfctl%l_runstat = .TRUE. ! switches and which areas produce reports with the proc integer settings. 1400 sn_cfctl%l_trcstat = .FALSE. ! The default settings for the proc integers should ensure 1401 sn_cfctl%l_oceout = .FALSE. ! that all areas report. 1402 sn_cfctl%l_layout = .FALSE. ! 1403 sn_cfctl%l_prtctl = .FALSE. ! 1404 sn_cfctl%l_prttrc = .FALSE. ! 1405 sn_cfctl%l_oasout = .FALSE. ! 1406 sn_cfctl%procmin = 0 ! Minimum area number for reporting [default:0] 1407 sn_cfctl%procmax = 1000000 ! Maximum area number for reporting [default:1000000] 1408 sn_cfctl%procincr = 1 ! Increment for optional subsetting of areas [default:1] 1409 sn_cfctl%ptimincr = 1 ! Timestep increment for writing time step progress info 1410 nn_print = 0 ! level of print (0 no extra print) 1411 nn_ictls = 0 ! start i indice of control sum (use to compare mono versus 1412 nn_ictle = 0 ! end i indice of control sum multi processor runs 1413 nn_jctls = 0 ! start j indice of control over a subdomain) 1414 nn_jctle = 0 ! end j indice of control 1415 nn_isplt = 1 ! number of processors in i-direction 1416 nn_jsplt = 1 ! number of processors in j-direction 1417 ln_timing = .false. ! timing by routine write out in timing.output file 1418 ln_diacfl = .false. ! CFL diagnostics write out in cfl_diagnostics.ascii 1402 sn_cfctl%l_runstat = .TRUE. ! switches and which areas produce reports with the proc integer settings. 1403 sn_cfctl%l_trcstat = .FALSE. ! The default settings for the proc integers should ensure 1404 sn_cfctl%l_oceout = .FALSE. ! that all areas report. 1405 sn_cfctl%l_layout = .FALSE. ! 1406 sn_cfctl%l_prtctl = .FALSE. ! 1407 sn_cfctl%l_prttrc = .FALSE. ! 1408 sn_cfctl%l_oasout = .FALSE. ! 1409 sn_cfctl%procmin = 0 ! Minimum area number for reporting [default:0] 1410 sn_cfctl%procmax = 1000000 ! Maximum area number for reporting [default:1000000] 1411 sn_cfctl%procincr = 1 ! Increment for optional subsetting of areas [default:1] 1412 sn_cfctl%ptimincr = 1 ! Timestep increment for writing time step progress info 1413 nn_print = 0 ! level of print (0 no extra print) 1414 nn_ictls = 0 ! start i indice of control sum (use to compare mono versus 1415 nn_ictle = 0 ! end i indice of control sum multi processor runs 1416 nn_jctls = 0 ! start j indice of control over a subdomain) 1417 nn_jctle = 0 ! end j indice of control 1418 nn_isplt = 1 ! number of processors in i-direction 1419 nn_jsplt = 1 ! number of processors in j-direction 1420 ln_timing = .false. ! timing by routine write out in timing.output file 1421 ln_diacfl = .false. ! CFL diagnostics write out in cfl_diagnostics.ascii 1419 1422 / 1420 1423 !-----------------------------------------------------------------------
Note: See TracChangeset
for help on using the changeset viewer.