New URL for NEMO forge!   http://forge.nemo-ocean.eu

Since March 2022 along with NEMO 4.2 release, the code development moved to a self-hosted GitLab.
This present forge is now archived and remained online for history.
Changeset 2349 for branches/nemo_v3_3_beta/DOC/TexFiles/Namelist/nambdy – NEMO

Ignore:
Timestamp:
2010-11-01T15:21:01+01:00 (13 years ago)
Author:
gm
Message:

v3.3beta: #658 phasing of the doc - key check + many minor changes

File:
1 edited

Legend:

Unmodified
Added
Removed
  • branches/nemo_v3_3_beta/DOC/TexFiles/Namelist/nambdy

    r2282 r2349  
    22&nambdy        !  unstructured open boundaries                          ("key_bdy") 
    33!----------------------------------------------------------------------- 
    4     filbdy_mask    =  ''                  !  name of mask file (if ln_bdy_mask=.TRUE.) 
    5     filbdy_data_T  = 'bdydata_grid_T.nc'  !  name of data file (T-points) 
    6     filbdy_data_U  = 'bdydata_grid_U.nc'  !  name of data file (U-points) 
    7     filbdy_data_V  = 'bdydata_grid_V.nc'  !  name of data file (V-points) 
    8     filbdy_data_bt_T  = 'bdydata_bt_grid_T.nc'  !  name of data file for Flather condition (T-points) 
    9     filbdy_data_bt_U  = 'bdydata_bt_grid_U.nc'  !  name of data file for Flather condition (U-points) 
    10     filbdy_data_bt_V  = 'bdydata_bt_grid_V.nc'  !  name of data file for Flather condition (V-points) 
    11     ln_bdy_clim    = .false.              !  contain 1 (T) or 12 (F) time dumps and be cyclic 
    12     ln_bdy_vol     = .true.               !  total volume correction (see volbdy parameter) 
    13     ln_bdy_mask    = .false.              !  boundary mask from filbdy_mask (T) or boundaries are on edges of domain (F) 
    14     ln_bdy_tides   = .true.               !  Apply tidal harmonic forcing with Flather condition 
    15     ln_bdy_dyn_fla = .true.               !  Apply Flather condition to velocities 
    16     ln_bdy_tra_frs = .false.              !  Apply FRS condition to temperature and salinity  
    17     ln_bdy_dyn_frs = .false.              !  Apply FRS condition to velocities 
    18     nbdy_dta       =  1                   !  = 0, bdy data are equal to the initial state 
    19                                           !  = 1, bdy data are read in 'bdydata   .nc' files 
    20     nb_rimwidth    = 9                    !  width of the relaxation zone 
    21     volbdy         = 0                    !  = 0, the total water flux across open boundaries is zero 
    22                                           !  = 1, the total volume of the system is conserved 
     4   cn_mask       =  ''                    !  name of mask file (if ln_bdy_mask=.TRUE.) 
     5   cn_dta_frs_T  = 'bdydata_grid_T.nc'    !  name of data file (T-points) 
     6   cn_dta_frs_U  = 'bdydata_grid_U.nc'    !  name of data file (U-points) 
     7   cn_dta_frs_V  = 'bdydata_grid_V.nc'    !  name of data file (V-points) 
     8   cn_dta_fla_T  = 'bdydata_bt_grid_T.nc' !  name of data file for Flather condition (T-points) 
     9   cn_dta_fla_U  = 'bdydata_bt_grid_U.nc' !  name of data file for Flather condition (U-points) 
     10   cn_dta_fla_V  = 'bdydata_bt_grid_V.nc' !  name of data file for Flather condition (V-points) 
     11   ln_clim       = .false.                !  contain 1 (T) or 12 (F) time dumps and be cyclic 
     12   ln_vol        = .true.                 !  total volume correction (see volbdy parameter) 
     13   ln_mask       = .false.                !  boundary mask from filbdy_mask (T) or boundaries on edges of domain (F) 
     14   ln_tides      = .true.                 !  Apply tidal harmonic forcing with Flather condition 
     15   ln_dyn_fla    = .true.                 !  Apply Flather condition to velocities 
     16   ln_tra_frs    = .false.                !  Apply FRS condition to temperature and salinity  
     17   ln_dyn_frs    = .false.                !  Apply FRS condition to velocities 
     18   nn_rimwidth   =  9                     !  width of the relaxation zone 
     19   nn_dtactl     =  1                     !  bdy data read in 'bdydata_...nc' (=1) or set to the initial state (=0) 
     20   nn_volctl     =  0                     !  set to zero the net flux across open boundaries (=0) including E-P-R (=1) 
    2321/ 
    2422 
Note: See TracChangeset for help on using the changeset viewer.