    21 '''Note:''' If the variable is only calculated for a specific option, it is good to add an exception in xios_orchidee_init. This avoids that the variable will be initialized in the output file without being written if you keep the same .xml files. For example if the variable new_var is only calculated for the case ok_newvar, then deactivated it for the other case as follow: 
     21'''Note:''' If the variable is only calculated for a specific option, it is good to add an exception in the subroutine xios_orchidee_init written in src_parallel/xios_orchidee.f90. This avoids that the variable will be initialized in the output file without being written. For example if the variable new_var is only calculated for the case ok_newvar, then deactivated it for the other case as follow: 
    2222 
    2323{{{ 
     
    2727 
    2828== 2. Modifications in the xml files == 
    29 All the xml files are stored in the model directory ORCHIDEE/src_xml. When using the libIGCM configurations, file_def_orchidee.xml is duplicated in PARAM/ directory and it is this file that will be considered.[[BR]] 
     29All the xml files are stored in the model directory ORCHIDEE/src_xml. When running the model using the libIGCM configurations, file_def_orchidee.xml is copied from ORCHIDEE/src_xml into PARAM/ directory during the simulation and it is this file that will be considered.[[BR]] 
    3030 
    3131=== field_def_orchidee.xml === 
     
    6464}}} 
    6565 
    66 For the moment, using XIOS1 it is not possible to have more than one vertical axis.[[BR]] 
     66For the moment, using XIOS1 it is not possible to have more than one vertical axis (e.g. solay and soildiag at the same time).[[BR]] 