Ignore:
Timestamp:
12/03/18 14:03:08 (4 years ago)
Author:
tlurton
Message:

New commit for scenario_CMIP6 experiment (starting from svn cp from historical_CMIP6).

File:
1 edited

Legend:

Unmodified
Added
Removed
  • CONFIG/UNIFORM/v6/IPSLCM6/EXPERIMENTS/IPSLCM/scenario_CMIP6/config.card

    r4139 r4162  
    99[UserChoices] 
    1010#=========================== 
    11 JobName= CM61-LR-hist-XX 
     11JobName=CM61-LR-scen-ssp245 
    1212#----- Short Name of Experiment 
    13 ExperimentName=historical 
     13#----- Possible values: ssp119 ; ssp126 ; ssp245 : ssp370 ; ssp434 ; ssp460 ; ssp534-over ; ssp585 
     14ExperimentName=ssp245 
    1415#----- DEVT TEST PROD 
    15 SpaceName=DEVT 
     16SpaceName=PROD 
    1617LongName="IPSLCM6.1.8-LR" 
    1718TagName=IPSLCM6 
     
    1920Member=r1i1p1f1 
    2021#D- Choice of experiment in EXPERIMENTS directory 
    21 ExpType=IPSLCM/historical_CMIP6 
     22ExpType=IPSLCM/scenario_CMIP6 
    2223#============================ 
    2324#-- leap, noleap, 360d 
     
    2526#-- Experiment dates : Beginning and ending 
    2627#-- "YYYY-MM-DD" 
    27 DateBegin=1850-01-01 
    28 DateEnd=2020-12-31 
     28DateBegin=2015-01-01 
     29DateEnd=2100-12-31 
    2930#============================ 
    3031ORCA_version=eORCA1.2 
     
    4243#D- If you want to restart all components from the same simulation, 
    4344#D-      put OveRule flag to 'y' and set the next 3 parameters 
    44 OverRule=n 
     45OverRule=y 
    4546#D- Last day of the experience used as restart for all components 
    46 RestartDate=1869-12-31 
     47RestartDate=2014-12-31 
    4748#D- Define restart simulation name for all components 
    48 RestartJobName=CM61-LR-pi-03 
    49 #D- Path Server Group Login 
    50 RestartPath=${R_IN}/RESTART/IPSLCM6/PROD/piControl 
     49RestartJobName=CM61-LR-hist-03.1910 
     50#D- Path Server Group Login 
     51RestartPath=${R_IN}/RESTART/IPSLCM6/PROD/historical 
    5152 
    5253#======================================================================== 
     
    5758Restart= y 
    5859# Last day of the experience used as restart for this component if Restart=y 
    59 RestartDate=1869-12-31 
    60 #D- Define restart simulation name for this component 
    61 RestartJobName=CM61-LR-pi-03 
    62 #D- Path Server Group Login 
    63 RestartPath=${R_IN}/RESTART/IPSLCM6/PROD/piControl 
     60RestartDate=2014-12-31 
     61#D- Define restart simulation name for this component 
     62RestartJobName=CM61-LR-hist-03.1910 
     63#D- Path Server Group Login 
     64RestartPath=${R_IN}/RESTART/IPSLCM6/PROD/historical 
    6465 
    6566#======================================================================== 
     
    7071Restart= y 
    7172##-- Last day of the experience used as restart for this component if Restart=y 
    72 RestartDate=1869-12-31 
    73 #D- Define restart simulation name for this component 
    74 RestartJobName=CM61-LR-pi-03 
    75 #D- Path Server Group Login 
    76 RestartPath=${R_IN}/RESTART/IPSLCM6/PROD/piControl 
     73RestartDate=2014-12-31 
     74#D- Define restart simulation name for this component 
     75RestartJobName=CM61-LR-hist-03.1910 
     76#D- Path Server Group Login 
     77RestartPath=${R_IN}/RESTART/IPSLCM6/PROD/historical 
    7778 
    7879#======================================================================== 
     
    8384Restart= y 
    8485##-- Last day of the experience used as restart for this component if Restart=y 
    85 RestartDate=1869-12-31 
    86 #D- Define restart simulation name for this component 
    87 RestartJobName=CM61-LR-pi-03 
    88 #D- Path Server Group Login 
    89 RestartPath=${R_IN}/RESTART/IPSLCM6/PROD/piControl 
     86RestartDate=2014-12-31 
     87#D- Define restart simulation name for this component 
     88RestartJobName=CM61-LR-hist-03.1910 
     89#D- Path Server Group Login 
     90RestartPath=${R_IN}/RESTART/IPSLCM6/PROD/historical 
    9091 
    9192#======================================================================== 
     
    9596Restart= y 
    9697##-- Last day of the experience used as restart for this component if Restart=y 
    97 RestartDate=1869-12-31 
    98 #D- Define restart simulation name for this component 
    99 RestartJobName=CM61-LR-pi-03 
    100 #D- Path Server Group Login 
    101 RestartPath=${R_IN}/RESTART/IPSLCM6/PROD/piControl 
     98RestartDate=2014-12-31 
     99#D- Define restart simulation name for this component 
     100RestartJobName=CM61-LR-hist-03.1910 
     101#D- Path Server Group Login 
     102RestartPath=${R_IN}/RESTART/IPSLCM6/PROD/historical 
    102103 
    103104#======================================================================== 
     
    109110Restart= y 
    110111# Last day of the experience used as restart for this component if Restart=y 
    111 RestartDate=1869-12-31 
    112 #D- Define restart simulation name for this component 
    113 RestartJobName=CM61-LR-pi-03 
    114 #D- Path Server Group Login 
    115 RestartPath=${R_IN}/RESTART/IPSLCM6/PROD/piControl 
     112RestartDate=2014-12-31 
     113#D- Define restart simulation name for this component 
     114RestartJobName=CM61-LR-hist-03.1910 
     115#D- Path Server Group Login 
     116RestartPath=${R_IN}/RESTART/IPSLCM6/PROD/historical 
    116117 
    117118#======================================================================== 
     
    123124Restart= y 
    124125# Last day of the experience used as restart for this component if Restart=y 
    125 RestartDate=1869-12-31 
    126 #D- Define restart simulation name for this component 
    127 RestartJobName=CM61-LR-pi-03 
    128 #D- Path Server Group Login 
    129 RestartPath=${R_IN}/RESTART/IPSLCM6/PROD/piControl 
     126RestartDate=2014-12-31 
     127#D- Define restart simulation name for this component 
     128RestartJobName=CM61-LR-hist-03.1910 
     129#D- Path Server Group Login 
     130RestartPath=${R_IN}/RESTART/IPSLCM6/PROD/historical 
    130131 
    131132#======================================================================== 
     
    136137Restart= y 
    137138# Last day of the experience used as restart for this component if Restart=y 
    138 RestartDate=1869-12-31 
    139 #D- Define restart simulation name for this component 
    140 RestartJobName=CM61-LR-pi-03 
    141 #D- Path Server Group Login 
    142 RestartPath=${R_IN}/RESTART/IPSLCM6/PROD/piControl 
     139RestartDate=2014-12-31 
     140#D- Define restart simulation name for this component 
     141RestartJobName=CM61-LR-hist-03.1910 
     142#D- Path Server Group Login 
     143RestartPath=${R_IN}/RESTART/IPSLCM6/PROD/historical 
    143144 
    144145#======================================================================== 
     
    151152RestartDate= 
    152153# Define restart simulation name for this component 
    153 RestartJobName= 
     154RestartJobName=CM61-LR-hist-03.1910 
    154155RestartPath= 
    155156 
Note: See TracChangeset for help on using the changeset viewer.