Changeset 1912 for XIOS/trunk/generic_testcase
- Timestamp:
- 06/26/20 13:17:56 (4 years ago)
- Location:
- XIOS/trunk/generic_testcase
- Files:
-
- 2 edited
Legend:
- Unmodified
- Added
- Removed
-
XIOS/trunk/generic_testcase/context_atm.xml
r1904 r1912 21 21 </axis_definition> 22 22 23 <axis_definition>24 <axis id="axis_zoom" axis_ref="axis">25 <zoom_axis begin="0" n="5"/>26 </axis>27 </axis_definition>28 29 23 <scalar_definition> 30 24 <scalar id="scalar" /> … … 129 123 </grid> 130 124 131 132 133 134 125 135 126 … … 228 219 </grid> 229 220 230 231 232 233 234 235 236 237 238 239 <grid id="grid_vert_reduce"> 240 <domain domain_ref="domain" /> 241 <scalar > 242 <reduce_axis operation="sum" /> 243 </scalar> 244 </grid> 245 246 <grid id="grid_horiz_reduce"> 247 <scalar > 248 <reduce_domain operation="sum" /> 249 </scalar> 250 <axis axis_ref="axis" /> 251 </grid> 252 253 <grid id="grid_zoom_vert"> 254 <domain domain_ref="domain" /> 255 <axis axis_ref="axis_zoom" /> 256 </grid> 257 258 <grid id="grid_zoom_vert_sum"> 259 <scalar > 260 <reduce_domain operation="sum" /> 261 </scalar> 262 <axis axis_ref="axis_zoom" /> 263 </grid> 264 265 <grid id="grid_lat"> 266 <axis axis_ref="domain_Y"> 267 <reduce_domain direction="iDir" operation="sum"/> 268 </axis> 269 <axis axis_ref="axis" /> 270 </grid> 271 272 273 <grid id="grid3D_invert"> 274 <domain domain_ref="domain"> 275 <reorder_domain invert_lat="true" /> 276 </domain> 277 <axis axis_ref="axis" /> 278 </grid> 279 280 <grid id="grid2D_invert"> 281 <domain domain_ref="domain"> 282 <reorder_domain invert_lat="true" shift_lon_fraction="0.5" min_lon="0" max_lon="360"/> 283 </domain> 284 </grid> 285 286 221 287 222 </grid_definition> 288 223 … … 290 225 <field_definition level="1" prec="8" operation="instant" freq_op="1ts" enabled=".true." default_value="1.e+20" detect_missing_value="true"> 291 226 <field id="field2D" grid_ref="grid2D" /> 292 <field id="field3D" grid_ref="grid3D" build_workflow_graph="true"/>227 <field id="field3D" grid_ref="grid3D" /> 293 228 <field id="pressure" grid_ref="grid3D" /> 294 229 <field id="field3D_recv" read_access="true" grid_ref="grid3D" field_ref="field3D" /> … … 303 238 <field id="field_YZ" grid_ref="grid_YZ" /> 304 239 305 <field id="field_zoom_vert" field_ref="field3D" grid_ref="grid_zoom_vert" />306 <field id="field_zoom_vert_sum" field_ref="field_zoom_vert" grid_ref="grid_zoom_vert_sum" />307 308 309 240 310 241 <field id="field2D_W" grid_ref="grid2D_W"/> … … 323 254 324 255 325 326 327 256 <field id="other_field2D" grid_ref="other_grid2D"/> 328 257 <field id="other_field3D" grid_ref="other_grid3D" /> … … 353 282 <field id="other_field_YZW" grid_ref="other_grid_YZW" /> 354 283 355 356 357 358 284 359 285 360 286 </field_definition> 287 288 289 290 <!-- implementation of specifics test case --> 291 <!-- simplest test cases : output data to file --> 292 361 293 362 294 363 295 <file_definition type="one_file" > 364 296 365 <file id="atm_output" output_freq="4ts" type="one_file" enabled="true"> 366 <!-- <field field_ref="field3D" /> 367 <field field_ref="field2D" /> 368 <field field_ref="field3D" grid_ref="grid_vert_reduce" name="field_vert_reduced" /> 369 <field field_ref="field3D" grid_ref="grid_horiz_reduce" name="field_horiz_reduced" /> 370 <field field_ref="field_zoom_vert" /> 371 <field field_ref="field_zoom_vert_sum" /> 372 <field field_ref="pressure" /> 373 <field field_ref="field3D_resend" /> --> 374 375 <field field_ref="field3D" enabled="true"/> 376 <field field_ref="field2D" enabled="true"/> 377 <field field_ref="field_X" enabled="true"/> 378 <field field_ref="field_Y" enabled="true"/> 379 <field field_ref="field_XY" enabled="true"/> 380 <field field_ref="field_Z" enabled="true"/> 381 <field field_ref="field_XYZ" enabled="true"/> 382 <field field_ref="field_XZ" enabled="true"/> 383 <field field_ref="field_YZ" enabled="true"/> 297 <file id="atm_output" output_freq="1ts" type="one_file" enabled="true"> 298 <field field_ref="field3D" /> 299 <field field_ref="field2D" /> 300 <field field_ref="field_X" /> 301 <field field_ref="field_Y" /> 302 <field field_ref="field_XY" /> 303 <field field_ref="field_Z" /> 304 <field field_ref="field_XYZ" /> 305 <field field_ref="field_XZ" /> 306 <field field_ref="field_YZ" /> 307 <field field_ref="pressure" /> 308 <field field_ref="field3D_resend" /> 384 309 </file> 385 310 386 311 <file id="atm_output_other" output_freq="1ts" type="one_file" enabled="true"> 387 <field field_ref="other_field3D" enabled="true"/> 388 <field field_ref="other_field2D" enabled="true"/> 389 <field field_ref="other_field_X" enabled="true"/> 390 <field field_ref="other_field_Y" enabled="true"/> 391 <field field_ref="other_field_XY" enabled="true"/> 392 <field field_ref="other_field_Z" enabled="true"/> 393 <field field_ref="other_field_XYZ" enabled="true"/> 394 <field field_ref="other_field_XZ" enabled="true"/> 395 <field field_ref="other_field_YZ" enabled="true"/> 312 <field field_ref="other_field3D" /> 313 <field field_ref="other_field2D" /> 314 <field field_ref="other_field_X" /> 315 <field field_ref="other_field_Y" /> 316 <field field_ref="other_field_XY" /> 317 <field field_ref="other_field_Z" /> 318 <field field_ref="other_field_XYZ" /> 319 <field field_ref="other_field_XZ" /> 320 <field field_ref="other_field_YZ" /> 321 <field field_ref="other_pressure" /> 322 <field field_ref="other_field3D_resend" /> 396 323 </file> 397 324 398 <file id="atm_output_W" output_freq="1ts" enabled=" false">399 <field field_ref="field3D_W" enabled="true"/>400 <field field_ref="field2D_W" enabled="true"/>401 <field field_ref="field_XW" enabled="true"/>402 <field field_ref="field_YW" enabled="true"/>403 <field field_ref="field_XYW" enabled="true"/>404 <field field_ref="field_ZW" enabled="true"/>405 <field field_ref="field_XYZW" enabled="true"/>406 <field field_ref="field_XZW" enabled="true"/>407 <field field_ref="field_YZW" enabled="true"/>325 <file id="atm_output_W" output_freq="1ts" enabled="true"> 326 <field field_ref="field3D_W" /> 327 <field field_ref="field2D_W" /> 328 <field field_ref="field_XW" /> 329 <field field_ref="field_YW" /> 330 <field field_ref="field_XYW" /> 331 <field field_ref="field_ZW" /> 332 <field field_ref="field_XYZW" /> 333 <field field_ref="field_XZW" /> 334 <field field_ref="field_YZW" /> 408 335 </file> 409 336 410 411 <file id="atm_output_reorder" output_freq="1ts" enabled="false" >412 <field field_ref="field2D" grid_ref="grid2D_invert" enabled="true"/>413 </file>414 415 <file id="test_grid_lat" output_freq="1ts" enabled="false">416 <field field_ref="field3D" operation="instant" />417 <field id="field_reduce_lat" field_ref="field3D" grid_ref="grid_lat" operation="instant" />418 </file>419 337 420 338 </file_definition> -
XIOS/trunk/generic_testcase/param.def
r1904 r1912 1 1 ¶ms_run 2 2 duration='1d' 3 nb_proc_atm= 43 nb_proc_atm=1 4 4 /
Note: See TracChangeset
for help on using the changeset viewer.