Custom Query (126 matches)

Filters
 
Or
 
  
 
Columns

Show under each result:


Results (88 - 90 of 126)

Ticket Resolution Summary Owner Reporter
#113 fixed XIOS attribute to specify netcdf attribute "cell_methods" ymipsl aclsce
Description

For CMIP6 workflow, the user needs to specify by hand, the netcdf attribute "cell_methods", especially when the requested cell_methods attribute is not associated to a XIOS filter. For example : "area: mean where land time: mean". Examples of cell_methids required by CMIP Data Request are here : http://clipc-services.ceda.ac.uk/dreq/index/cellMethods.html

#114 fixed Output_freq non initialized do not raise error message ? ymipsl ymipsl
Description

Checking this point that has been reported by S.Farroux

#116 fixed reduce_domain workflow issue when combined with vertical interpolation ymipsl ssenesi
Description

Using r1028 and a toy derived from test_xios2_cmpi6 (attached) , which also sends a pressure field, I am able to correctly derive :

  • a profile of a 3D field (with a 'reduce_domain' applied on horizontal domain)
  • a vertical interpolation of the same field on pressure levels

but when trying to get the profile of the vertically interpolated field, I get sensible values only for the first output timestep; for the remaining timsteps the values are largely underestimated, and their vertical structure is unconsistent with the original field

The set of xml files and the output file are attached.

Note: See TracQuery for help on using queries.