#606 closed Bug (fixed)
emp conversion to m/s
Reported by: | rblod | Owned by: | smasson |
---|---|---|---|
Priority: | low | Milestone: | |
Component: | OCE | Version: | v3.2 |
Severity: | Keywords: | OPA SBC v3.2 | |
Cc: |
Description
We now use rau0 instead of rauw to obtain emp in m/s (emp/rau0). Furthermore, rau0 is now change from 1020 to 1035 kg/m3. I add in attachment a clean version of phycst.
Commit History (1)
Changeset | Author | Time | ChangeLog |
---|---|---|---|
1739 | rblod | 2009-11-19T14:24:00+01:00 | Use rau0 instead of rauw for sbc, uchange rau0 to 1035, see ticket #606 |
Attachments (1)
Change History (10)
Changed 15 years ago by rblod
comment:1 Changed 15 years ago by anonymous
- Milestone 2009 Stream 0: Coupled Ready deleted
comment:2 Changed 15 years ago by smasson
- Owner changed from NEMO team to smasson
comment:3 Changed 15 years ago by smasson
- Status changed from new to assigned
comment:4 Changed 14 years ago by smasson
- Resolution set to fixed
- Status changed from assigned to closed
done, see changeset:1931 and changeset:1932
comment:5 Changed 8 years ago by nicolasmartin
- Keywords SBC added; sbc removed
comment:6 Changed 8 years ago by nicolasmartin
- Keywords nemo_v3_2* added
comment:7 Changed 8 years ago by nicolasmartin
- Keywords emp removed
comment:8 Changed 7 years ago by nemo
- Keywords nemo_v3_2* removed
comment:9 Changed 3 years ago by nemo
- Keywords OPA v3.2 added
Note: See
TracTickets for help on using
tickets.
Milestone 2009 Stream 0: Coupled Ready deleted