Opened 14 years ago
Closed 12 years ago
#667 closed Bug (fixed)
lbc_lnk on emp
Reported by: | molines | Owned by: | smasson |
---|---|---|---|
Priority: | high | Milestone: | |
Component: | OCE | Version: | v3.4 |
Severity: | Keywords: | ||
Cc: |
Description
- this concerns ORCA configuration, at least ORCA025 and ORCA05.
- This problem was raised in ticket #424: We need to have a call to lbc_lnk(emp) ( actually at the end of sbcmod.F90).
- It was once claimed that this was necessary because of input data not previously 'filtered' by a lbc_lnk. Thus the ticket #424 was labeled invalid ...
- Now, we are running with Interpolation On the Fly and we also need this fix, even if we do not really inderstand why !
- If you do not have it, the model blows up in the arctic within 6 months from start.
Commit History (2)
Changeset | Author | Time | ChangeLog |
---|---|---|---|
2503 | rblod | 2010-12-22T15:33:04+01:00 | Ugly fix for #667 for safety in 3.2 |
2502 | rblod | 2010-12-22T15:32:50+01:00 | Ugly fix for #667 for safety in 3.2 |
Change History (2)
comment:1 Changed 12 years ago by vichi
- Owner changed from NEMO team to smasson
- Version changed from v3.2 to v3.4
comment:2 Changed 12 years ago by smasson
- Resolution set to fixed
- Status changed from new to closed
Note: See
TracTickets for help on using
tickets.
done (even if we don't understand why...) in r2502