Version 43 (modified by nicolasmartin, 6 years ago) (diff) |
---|
TOP interface User Quick Guide
The present Quick Guide applies to NEMO 4.0+ releases.
TOP interface Structure
TOP (Tracers in the Ocean Paradigm) is the NEMO hardwired interface toward biogeochemical models and provide the physical constraints/boundaries for oceanic tracers. It consists of a modular framework to handle multiple ocean tracers, including also a variety of built-in modules.
This component of the NEMO framework allows one to exploit available modules (see below) and further develop a range of applications, spanning from the implementation of a dye passive tracer to evaluate dispersion processes (by means of MY_TRC), track water masses age (AGE module), assess the ocean interior penetration of persistent chemical compounds (e.g., gases like CFC or even PCBs), up to the full set of equations involving marine biogeochemical cycles.
TOP interface has the following location in the code repository
<repository>/NEMOGCM/NEMO/TOP_SRC/
and the following modules are available:
TRP | Interface to NEMO physical core for computing tracers transport |
CFC | Inert carbon tracers (CFC11,CFC12, SF6) |
C14 | Radiocarbon passive tracer |
AGE | Water age tracking |
MY_TRC | Template for creation of new modules and external BGC models coupling |
PISCES | Built in BGC model. See Aumont et al. (2015) for a throughout description. |
The usage of TOP is activated i) by including in the configuration definition the component TOP_SRC and ii) by adding the macro key_top in the configuration cpp file (see for more details Learn more about the model).
As an example, the user can refer to already available configurations in the code, GYRE_PISCES being the NEMO biogeochemical demonstrator and GYRE_BFM to see the required configuration elements to couple with an external biogeochemical model (see also Section 4) .
Note that, since version 4.0, TOP interface core functionalities are activated by means of logical keys and all submodules preprocessing macros from previous versions were removed.
Here below the list of preprocessing keys that applies to the TOP interface (beside key_top):
key_iomput : use XIOS I/O
key_zdfddm & key_zdftke & key_zdfgls: vertical schemes (need to be updated after Merge2017 finalization)
key_trabbl : bottom boundary layer parameterization
key_agrif : enable AGRIF coupling
key_trdtrc & key_trdmxl_trc : trend computation for tracers
TOP synthetic Workflow
A synthetic description of the TOP interface workflow is given below to summarize the steps involved in the computation of biogeochemical and physical trends and their time integration and outputs, by reporting also the principal Fortran subroutine herein involved.
Model initialization (OPA_SRC/nemogcm.F90)
call to trc_init (trcini.F90)
↳ call trc_nam (trcnam.F90) to initialize TOP tracers and run setting
↳ call trc_ini_sms, to initialize each submodule
↳ call trc_ini_trp, to initialize transport for tracers
↳ call trc_ice_ini, to initialize tracers in seaice
↳ call trc_ini_state, read passive tracers from a restart or input data
↳ call trc_sub_ini, setup substepping if nn_dttrc /= 1
Time marching procedure (OPA_SRC/stp.F90)
call to trc_stp.F90 (trcstp.F90)
↳ call trc_sub_stp, averaging physical variables for sub-stepping
↳ call trc_wri, call XIOS for output of data
↳ call trc_sms, compute BGC trends for each submodule
↳ call trc_sms_my_trc, includes also surface and coastal BCs trends
↳ call trc_trp (TRP/trctrp.F90), compute physical trends
↳ call trc_sbc, get trend due to surface concentration/dilution
↳ call trc_adv, compute tracers advection
↳ call to trc_ldf, compute tracers lateral diffusion
↳ call to trc_zdf, vertical mixing and after tracer fields
↳ call to trc_nxt, tracer fields at next time step. Lateral Boundary Conditions are solved in here.
↳ call to trc_rad, Correct artificial negative concentrations
↳ call trc_rst_wri, output tracers restart files
TOP namelists Walkthrough
namelist_top
Here below are listed the features/options of the TOP interface accessible through the namelist_top_ref and modifiable by means of namelist_top_cfg (as for NEMO physical ones).
Note that ## is used to refer to a number in an array field.
IncludeSource(/NEMO/trunk/cfgs/SHARED/namelist_top_ref, start=13, end=26, line_numbers=0)?
&namtrc_run ! run information | |
nn_dttrc | Time step frequency for TOP computation (if >1 substepping is used) |
ln_top_euler | Use Euler Forward integration instead of leap-frog |
ln_rsttr | Start from a restart file (T) or not (F) |
nn_rsttr | Restart control. 0 : initial time step is not compared to the restart file value. 1 : do not use the value in the restart file. 2 : calendar parameters read in the restart file. |
cn_trcrst_in cn_trcrst_indir | Suffix of tracers INPUT restart file Root directory for the location of INPUT restart files |
cn_trcrst_out cn_trcrst_outdir | suffix of tracers OUTPUT restart file Root directory for the location of OUTPUT restart files |
IncludeSource(/NEMO/trunk/cfgs/SHARED/namelist_top_ref, start=27, end=49, line_numbers=0)?
&namtrc ! tracers definition | |
jp_bgc | Number of passive tracers of the BGC model |
ln_pisces / ln_my_trc | Run PISCES or MY_TRC BGC modules. These modules cannot be run at the same time since they both rely on jp_bgc |
ln_age, ln_cfc11, ln_cfc12, ln_sf6, ln_c14 | Activate sub-modules: tracers are automatically defined within each module. These can run along with main BGC modules. |
ln_trcdta | Initialisation from data input file (T) or not (F) |
ln_trcdmp ln_trcdmp_clo | Add a damping term (T) or not (F) Add a damping term (T) or not (F) for closed seas |
jp_dia3d, jp_dia2d | Number of 3D/2D diagnostic variables to populate dedicated array beside the direct usage of iom_put calls. |
sn_tracer(##) | Data structure to specify tracer name and metadata for the chosen BGC module. Here set initialization and Boundary conditions. See structure description after this table. |
IncludeSource(/NEMO/trunk/cfgs/SHARED/namelist_top_ref, start=56, end=64, line_numbers=0)?
&namtrc_dta ! Initialisation from data input file | |
sn_trcdta(##) | Data structure to read tracers Initial conditions according to sn_tracer%llinit option. See structure description after this table. |
rf_trfac(##) | Multiplicative factor for initialized tracer. If omitted default is 1.0. |
cn_dir | Root directory for the location of INPUT data files |
IncludeSource(/NEMO/trunk/cfgs/SHARED/namelist_top_ref, start=65, end=80, line_numbers=0)?
&namtrc_adv ! advection scheme for passive tracer | |
ln_trcadv_OFF | No passive tracer advection |
ln_trcadv_cen nn_cen_h nn_cen_v | 2nd order centered scheme =2 or 4, horizontal 2nd / 4th order =2 or 4, vertical 2nd / 4th order |
ln_trcadv_fct nn_fct_h nn_fct_v nn_fct_zts | FCT scheme =2 or 4, horizontal 2nd / 4th order =2 or 4, vertical 2nd / 4th order >=1, number of sub-timestep for 2nd order vertical scheme |
ln_trcadv_mus ln_mus_ups | MUSCL scheme use (T) or not (F) upstream scheme near river mouths |
ln_trcadv_ubs nn_ubs_v | UBS scheme = 2 , vertical 2nd order FCT |
ln_trcadv_qck | QUICKEST scheme |
IncludeSource(/NEMO/trunk/cfgs/SHARED/namelist_top_ref, start=81, end=90, line_numbers=0)?
&namtrc_ldf ! lateral diffusion scheme for passive tracer | |
ln_trcldf_OFF | No passive tracer diffusion |
ln_trcldf_tra | Use the same diffusion of active tracers |
rn_ldf_multi | Multiplier of active tracers mixing coefficient (aht) |
rn_fact_lap | Equatorial enhanced zonal eddy diffusivity (laplacian only) |
IncludeSource(/NEMO/trunk/cfgs/SHARED/namelist_top_ref, start=91, end=95, line_numbers=0)?
&namtrc_rad ! treatment of negative concentrations | |
ln_trcrad | Artificially correct negative concentrations (T) or not (F) |
IncludeSource(/NEMO/trunk/cfgs/SHARED/namelist_top_ref, start=96, end=103, line_numbers=0)?
&namtrc_dmp ! passive tracer newtonian damping | |
nn_zdmp_tr | Vertical shape of damping term 0 : damping throughout the water column 1 : no damping in the mixing layer (kz criteria) 2 : no damping in the mixed layer (rho crieria) |
cn_resto_tr | NetCDF filename with input damping coefficients |
IncludeSource(/NEMO/trunk/cfgs/SHARED/namelist_top_ref, start=104, end=111, line_numbers=0)?
&namtrc_ice ! Representation of sea ice growth & melt effects | |
nn_ice_tr | Tracer concentration in sea ice. Available options -1 (no vvl: identical cc in ice and ocean / vvl: cc_ice = 0) 0 (no vvl: cc_ice = zero / vvl: cc_ice = ) 1 prescribed to a namelist value (implemented in pisces or through user definition in trcice_my_trc) |
IncludeSource(/NEMO/trunk/cfgs/SHARED/namelist_top_ref, start=112, end=124, line_numbers=0)?
&namtrc_trd ! diagnostics on tracer trends ('key_trdtrc') | |
nn_trd_trc | Time step frequency and tracers trends |
nn_ctls_trc | Control surface type in mixed-layer trends (0,1 or n<jpk) |
rn_ucf_trc | Unit conversion factor (=1 -> /seconds ; =86400. -> /day) |
ln_trdmld_trc_restart | Use restart (T) or not (F) for ML diagnostics |
ln_trdmld_trc_instant | Diagnose trends of instantaneous (T) or mean (F) ML T/S |
ln_trdtrc(##) | Compute trend for nth tracer. Array of logical values. |
IncludeSource(/NEMO/trunk/cfgs/SHARED/namelist_top_ref, start=125, end=133, line_numbers=0)?
&namtrc_bc ! Forcing data for boundary conditions | |
sn_trcsbc(##), sn_trccbc(##), sn_trcobc(##) | Data structure to read tracers boundary conditions according to sn_tracer%llsbc,sn_tracer%llcbc, sn_tracer%llobc options. See structure description after this table. |
rn_trsfac(##), rn_trcfac(##), rn_trofac(##) | Multiplicative factor for SURFACE (sbc), COASTAL (cbc), and LATERAL (obc) forcing data files |
cn_dir_sbc, cn_dir_cbc, cn_dir_obc | Root directory for the location of SURFACE (sbc), COASTAL (cbc), and LATERAL (obc) forcing data files |
ln_rnf_ctl | Remove runoff dilution on tracers with absent river load (only without VVL) |
rn_bc_time | Time scaling factor for SBC and CBC data (seconds in a day) |
IncludeSource(/NEMO/trunk/cfgs/SHARED/namelist_top_ref, start=134 , line_numbers=0)?
&namtrc_bdy ! Setup of tracer boundary conditions | |
cn_trc_dflt | Open Boundary Condition applied by default to all tracers |
cn_trc | Boundary conditions used for tracers with data files (selected in namtrc using sn_tracer%llobc) |
nn_trcdmp_bdy | Use damping timescales defined in nambdy of namelist 0 : NO damping of tracers at open boundaries 1 : Only for tracers forced with external data 2 : Damping applied to all tracers |
IncludeSource(/NEMO/trunk/cfgs/SHARED/namelist_top_ref, start=50, end=55, line_numbers=0)?
&namage ! Water Age module | |
rn_age_depth | Depth over which age tracer reset to zero |
rn_age_kill_rate | Relaxation timescale (s) for age tracer shallower than age depth |
Two main types of data structure are used within TOP interface to initialize tracer properties (1) and to provide related initial and boundary conditions (2).
1. TOP tracers initialization : sn_tracer (namtrc)
Beside providing name and metadata for tracers, here are also defined the use of initial (sn_tracer%llinit) and boundary (sn_tracer%llsbc, sn_tracer%llcbc, sn_tracer%llobc) conditions.
In the following, an example of the full structure definition is given for two idealized tracers both with initial conditions given, while the first has only surface boundary forcing and the second both surface and coastal forcings:
! ! name ! title of the field ! units ! initial data ! sbc ! cbc ! obc ! sn_tracer(1) = 'TRC1' , 'Tracer 1 Concentration ', ' - ' , .true. , .true., .false., .true. sn_tracer(2) = 'TRC2 ' , 'Tracer 2 Concentration ', ' - ' , .true. , .true., .true. , .false.
As tracers in BGC models are increasingly growing, the same structure can be written also in a more compact and readable way:
! ! name ! title of the field ! units ! initial data ! sn_tracer(1) = 'TRC1' , 'Tracer 1 Concentration ', ' - ' , .true. sn_tracer(2) = 'TRC2 ' , 'Tracer 2 Concentration ', ' - ' , .true. ! sbc sn_tracer(1)%llsbc = .true. sn_tracer(2)%llsbc = .true. ! cbc sn_tracer(2)%llcbc = .true.
The data structure is internally initialized by code with dummy names and all initialization/forcing logical fields set to .false. .
2. Structures to read input initial and boundary conditions :namtrc_dta (sn_trcdta), namtrc_bc (sn_trcsbc/sn_trccbc/sn_trcobc)
The overall data structure (Fortran type) is based on the general one defined for NEMO core in the SBC component (see details in User Manual SBC Chapter on Input Data specification).
Input fields are prescribed within namtrc_dta (with sn_trcdta structure), while Boundary Conditions are applied to the model by means of namtrc_bc, with dedicated structure fields for surface (sn_trcsbc), riverine (sn_trccbc), and lateral open (sn_trcobc) boundaries.
The following example illustrates the data structure in the case of initial condition for a single tracer contained in the file named tracer_1_data.nc (.nc is implicitly assumed in namelist filename), with a doubled initial value, and located in the usr/work/model/inputdata/ folder:
! ! file name ! frequency (hours) ! variable ! time interp. ! clim ! 'yearly'/ ! weights ! rotation ! land/sea mask ! ! ! ! (if <0 months) ! name ! (logical) ! (T/F) ! 'monthly' ! filename ! pairing ! filename ! sn_trcdta(1) = 'tracer_1_data' , -12 , 'TRC1' , .false. , .true. , 'yearly' , '' , '' , '' rf_trfac(1) = 2.0 cn_dir = “usr/work/model/inputdata/”
Note that, the Lateral Open Boundaries conditions are applied on the segments defined for the physical core of NEMO (see BDY description in the User Manual).
namelist_trc
Here below the description of namelist_trc_ref used to handle Carbon tracers modules, namely CFC and C14.
source:/NEMO/trunk/cfgs/SHARED/namelist_trc_ref IncludeSource(/NEMO/trunk/cfgs/SHARED/namelist_trc_ref, start=6, end=14, line_numbers=0)?
&namcfc ! CFC | |
ndate_beg | Initial calendar date (yymmdd) for CFC |
nyear_res | Restoring time constant (year) |
clname | Name of formatted file with annual hemisperic CFCs concentration in the atmosphere (ppt) |
IncludeSource(/NEMO/trunk/cfgs/SHARED/namelist_trc_ref, start=16, end=23, line_numbers=0)?
&namc14_typ ! C14 - type of C14 tracer, default values of C14/C and pco2 | |
kc14typ | Type of C14 tracer (0=equilibrium; 1=bomb transient; 2=past transient) |
rc14at | Default value for atmospheric C14/C (used for equil run) |
pco2at | Default value for atmospheric pcO2 [atm] (used for equil run) |
rc14init | Default value for initialization of ocean C14/C (when no restart) |
IncludeSource(/NEMO/trunk/cfgs/SHARED/namelist_trc_ref, start=25, end=31, line_numbers=0)?
&namc14_sbc ! C14 - surface BC | |
ln_chemh | Use (T) or not (F) Chemical enhancement in piston velocity |
xkwind | Coefficient for gas exchange velocity |
xdicsur | Reference DIC surface concentration (mol/m3) |
IncludeSource(/NEMO/trunk/cfgs/SHARED/namelist_trc_ref, start=33, end=44, line_numbers=0)?
&namc14_fcg ! files & dates | |
cfileco2 | Name of formatted file with atmospheric co2 - Bomb |
cfilec14 | Name of formatted file with atmospheric c14 - Bomb |
tyrc14_beg | starting year of experiment - Bomb |
MY_TRC interface for coupling external BGC models
The generalized interface is pivoted on MY_TRC module that contains template files to build the coupling between NEMO and any external BGC model.
The call to MY_TRC is activated by setting ln_my_trc = .true. (in namtrc)
The following 6 fortran files are available in MY_TRC with the specific purposes here described.
par_my_trc.F90
This module allows to define additional arrays and public variables to be used within the MY_TRC interface
trcini_my_trc.F90
Here are initialized user defined namelists and the call to the external BGC model initialization procedures to populate general tracer array (trn and trb). Here are also likely to be defined suport arrays related to system metrics that could be needed by the BGC model.
trcnam_my_trc.F90
This routine is called at the beginning of trcini_my_trc and should contain the initialization of additional namelists for the BGC model or user-defined code.
trcsms_my_trc.F90
The routine performs the call to Boundary Conditions and its main purpose is to contain the Source-Minus-Sinks terms due to the biogeochemical processes of the external model. Be aware that lateral boundary conditions are applied in trcnxt routine. IMPORTANT: the routines to compute the light penetration along the water column and the tracer vertical sinking should be defined/called in here, as generalized modules are still missing in the code.
trcice_my_trc.F90
Here it is possible to prescribe the tracers concentrations in the seaice that will be used as boundary conditions when ice melting occurs (nn_ice_tr =1 in namtrc_ice). See e.g. the correspondent PISCES subroutine.
trcwri_my_trc.F90
This routine performs the output of the model tracers (only those defined in namtrc) using IOM module (see Manual Chapter “Output and Diagnostics”). It is possible to place here the output of additional variables produced by the model, if not done elsewhere in the code, using the call to iom_put.
Coupling an external BGC model using NEMO framework
The coupling with an external BGC model through the NEMO compilation framework can be achieved in different ways according to the degree of coding complexity of the Biogeochemical model, like e.g., the whole code is made only by one file or it has multiple modules and interfaces spread across several subfolders.
Beside the 6 core files of MY_TRC module, let’s assume an external BGC model named “MYBGC” and constituted by a rather essential coding structure, likely few Fortran files. The new coupled configuration name is NEMO_MYBGC.
The best solution is to have all files (the modified MY_TRC routines and the BGC model ones) placed in a unique folder with root <MYBGCPATH> and to use the makenemo external readdressing of MY_SRC folder.
The coupled configuration listed in cfg.txt will look like
NEMO_MYBGC OPA_SRC TOP_SRC
and the related cpp_MYBGC.fcm content will be
bld::tool::fppkeys key_zdftke key_dynspg_ts key_iomput key_mpp_mpi key_top
the compilation with makenemo will be executed through the following syntax
makenemo -n NEMO_MYBGC -m <arch_my_machine> -j 8 -e <MYBGCPATH>
The makenemo feature “-e” was introduced to readdress at compilation time the standard MY_SRC folder (usually found in NEMO configurations) with a user defined external one.
The compilation of more articulated BGC model code & infrastructure, like in the case of BFM (BFM-NEMO coupling manual), requires some additional features.
As before, let’s assume a coupled configuration name NEMO_MYBGC, but in this case MYBGC model root becomes <MYBGCPATH> that contains 4 different subfolders for biogeochemistry, named initialization, pelagic, and benthic, and a separate one named nemo_coupling including the modified MY_SRC routines. The latter folder containing the modified NEMO coupling interface will be still linked using the makenemo “-e” option.
In order to include the BGC model subfolders in the compilation of NEMO code, it will be necessary to extend the configuration cpp_NEMO_MYBGC.fcm file to include the specific paths of MYBGC folders, as in the following example
bld::tool::fppkeys key_zdftke key_dynspg_ts key_iomput key_mpp_mpi key_top src::MYBGC::initialization <MYBGCPATH>/initialization src::MYBGC::pelagic <MYBGCPATH>/pelagic src::MYBGC::benthic <MYBGCPATH>/benthic bld::pp::MYBGC 1 bld::tool::fppflags::MYBGC %FPPFLAGS bld::tool::fppkeys %bld::tool::fppkeys MYBGC_MACROS
where MYBGC_MACROS is the space delimited list of macros used in MYBGC model for selecting/excluding specific parts of the code. The BGC model code will be preprocessed in the configuration BLD folder as for NEMO, but with an independent path, like NEMO_MYBGC/BLD/MYBGC/<subforlders>.
The compilation will be performed similarly to in the previous case with the following
makenemo -n NEMO_MYBGC -m <arch_my_machine> -j 8 -e <MYBGCPATH>/nemo_coupling
Note that, the additional lines specific for the BGC model source and build paths, can be written into a separate file, e.g. named MYBGC.fcm, and then simply included in the cpp_NEMO_MYBGC.fcm as follow
bld::tool::fppkeys key_zdftke key_dynspg_ts key_iomput key_mpp_mpi key_top inc <MYBGCPATH>/MYBGC.fcm
This will enable a more portable compilation structure for all MYBGC related configurations.
Important: the coupling interface contained in nemo_coupling cannot be added using the FCM syntax, as the same files already exists in NEMO and they are overridden only with the readdressing of MY_SRC contents to avoid compilation conflicts due to duplicate routines.
All modifications illustrated above, can be easily implemented using shell or python scripting to edit the NEMO configuration cpp.fcm file and to create the BGC model specific FCM compilation file with code paths.