Changes between Version 18 and Version 19 of ticket/1851/General
- Timestamp:
- 2017-02-24T14:57:00+01:00 (8 years ago)
Legend:
- Unmodified
- Added
- Removed
- Modified
-
ticket/1851/General
v18 v19 178 178 So in the restart case it occurs at TS=38, 43, 48, 53 etc while in the NRUN case is arises at TS=36, 41, 46, 51 etc. 179 179 180 This comes from the vn3.6 NEMO_stable branch via the GO6 branch, and is not specific to the MEDUSA branch. But it looks utter garbage.181 182 The description says "In coupled mode, the sampling is done at every coupling frequency", which is not what happens at all because,180 This comes from the vn3.6 NEMO_stable branch via the GO6 branch, and is not specific to the MEDUSA branch. But the logic looks completely inconsistent. 181 182 The description says "In coupled mode, the sampling is done at every coupling frequency", which is nothing like what happens at all because, 183 183 with a 45 minute TS and a coupling frequency of 3 hours which we have in our model: 184 184 … … 189 189 190 190 191 192 193 194 195 196 197 198 199 191 iseclast = 20834550 and never changes. 192 isecfst changes as things progress. 193 nsec_year = 20834550 194 nsec1jan000 = 0 195 rdt_sampl = 10800 196 nb_rec_per_day = 8 197 198 So what does this all mean? 199 200 201 202 203 204 205 206 207 208