Opened 7 years ago

Closed 7 years ago

#265 closed enhancement (fixed)

Activate hydraulic architecture

Reported by: luyssaert Owned by: alanso
Priority: major Milestone: IPSLCM6.v2
Component: Biogeochemical processes Version:
Keywords: Cc:

Description

(1) Activate hydraulic architecture. (2) Check whether the waterstress is correctly passed between sechiba and stomate.

Change History (5)

comment:1 Changed 7 years ago by luyssaert

  • Type changed from defect to enhancement

comment:2 Changed 7 years ago by alanso

  • Owner changed from somebody to alanso
  • Status changed from new to accepted

comment:3 Changed 7 years ago by alanso

  • Resolution set to fixed
  • Status changed from accepted to closed

Several bugs were fix before the hydraulic architecture worked correctly. The major ones are:

  • swc was calculated and added to the argument list in hydrol_main, as swc is neeed in the hydrol_arch routine
  • the variables unstressed and stressed were not include in the argument list or declared in sechiba_mleb_hs subroutine. They were only declared as module variables, and thus the the information were not passed correctly around between the subroutines.

Futhermore, a little cleaning has been done with the following unused variables; veg_soiltext, sfcfrz, radsink,radxs,soilfxresiel.

comment:4 Changed 7 years ago by luyssaert

  • Resolution fixed deleted
  • Status changed from closed to reopened

The ticket was re-opened because this tasks needs to be redone for the merge with the trunk.

comment:5 Changed 7 years ago by alanso

  • Resolution set to fixed
  • Status changed from reopened to closed
Note: See TracTickets for help on using tickets.