Aerodynamic resistance is not used in the calculation of the GPP

Reported by: gmarie Owned by: somebody
Priority: major Milestone: ORCHIDEE 4.3
Component: Biogeochemical processes Version: trunc
Keywords: upscaling, photosynthesis, aerodynamic resistance Cc:

Description

Both transpiration and photosynthesis have to be upscale from the leaf to the canopy in order to be compared with flux tower measurement. It is done for transpiration through the stomatal conductance and vbeta3 but not for the GPP because the recalculation of gs happen after the calculation of GPP.

Change History (1)

comment:1 Changed 9 months ago by gmarie

  • Milestone changed from ORCHIDEE 4.2 to ORCHIDEE 4.3