Changes between Version 2 and Version 3 of 2016WP/NocWad
- Timestamp:
- 2016-04-07T12:50:56+02:00 (8 years ago)
Legend:
- Unmodified
- Added
- Removed
- Modified
-
2016WP/NocWad
v2 v3 54 54 advection is the main process causing the wetting and drying on the grid cells (with the 55 55 evaporation and precipitation as the other two reasons which will be dealt separately). 56 For such a control volume V, we can define a flux limiter as follows: 57 58 [[Image(math figs/fig01.png)]] 56 For such a control volume V, we can define a flux limiter, [[Image(fig01.png)]], as follows: 57 58 The overshooting flux across a W/D grid cell is: 59 60 [[Image(fig02.png)]] 61 62 To preserve the positivity of water mass at each cell, the limiter coefficient [[Image(fig01.png)]] must satisfy: 63 64 [[Image(fig04.png)]] 65 66 59 67 60 68 This section should be completed before starting to develop the code, in order to find agreement on the method beforehand.