New URL for NEMO forge!   http://forge.nemo-ocean.eu

Since March 2022 along with NEMO 4.2 release, the code development moved to a self-hosted GitLab.
This present forge is now archived and remained online for history.
Changeset 11872 for NEMO/branches/2019/fix_sn_cfctl_ticket2328/cfgs/SHARED/namelist_ref – NEMO

Ignore:
Timestamp:
2019-11-07T17:55:13+01:00 (5 years ago)
Author:
acc
Message:

Branch 2019/fix_sn_cfctl_ticket2328. See #2328. Replacement of ln_ctl and activation of full functionality with
sn_cfctl structure. These changes rename structure components l_mppout and l_mpptop as l_prtctl and l_prttrc
and introduce l_glochk to activate former ln_ctl code in stpctl.F90 to perform global location of min and max
checks. Also added is l_allon which can be used to activate all output (much like the former ln_ctl). If l_allon
is .false. then l_config decides whether or not the suboptions are used.

   sn_cfctl%l_glochk = .FALSE.    ! Range sanity checks are local (F) or global (T). Set T for debugging only
   sn_cfctl%l_allon  = .FALSE.    ! IF T activate all options. If F deactivate all unless l_config is T
   sn_cfctl%l_config = .TRUE.     ! IF .true. then control which reports are written with the remaining options

Note, these changes pass SETTE tests but all references to ln_ctl need to be removed from the sette scripts.

File:
1 edited

Legend:

Unmodified
Added
Removed
  • NEMO/branches/2019/fix_sn_cfctl_ticket2328/cfgs/SHARED/namelist_ref

    r11869 r11872  
    13221322&namctl        !   Control prints                                       (default: OFF) 
    13231323!----------------------------------------------------------------------- 
    1324    ln_ctl = .FALSE.                 ! Toggle all report printing on/off (T/F); Ignored if sn_cfctl%l_config is T 
     1324   sn_cfctl%l_glochk = .FALSE.    ! Range sanity checks are local (F) or global (T). Set T for debugging only 
     1325   sn_cfctl%l_allon  = .FALSE.    ! IF T activate all options. If F deactivate all unless l_config is T 
    13251326     sn_cfctl%l_config = .TRUE.     ! IF .true. then control which reports are written with the following 
    13261327       sn_cfctl%l_runstat = .FALSE. ! switches and which areas produce reports with the proc integer settings. 
     
    13281329       sn_cfctl%l_oceout  = .FALSE. ! that  all areas report. 
    13291330       sn_cfctl%l_layout  = .FALSE. ! 
    1330        sn_cfctl%l_mppout  = .FALSE. ! 
    1331        sn_cfctl%l_mpptop  = .FALSE. ! 
     1331       sn_cfctl%l_prtctl  = .FALSE. ! 
     1332       sn_cfctl%l_prttrc  = .FALSE. ! 
    13321333       sn_cfctl%l_oasout  = .FALSE. ! 
    13331334       sn_cfctl%procmin   = 0       ! Minimum area number for reporting [default:0] 
Note: See TracChangeset for help on using the changeset viewer.