New URL for NEMO forge!   http://forge.nemo-ocean.eu

Since March 2022 along with NEMO 4.2 release, the code development moved to a self-hosted GitLab.
This present forge is now archived and remained online for history.
Changeset 9526 for branches/2017/dev_merge_2017/NEMOGCM/NEMO/OPA_SRC/DYN/dynadv.F90 – NEMO

Ignore:
Timestamp:
2018-04-30T12:22:35+02:00 (6 years ago)
Author:
gm
Message:

dev_merge_2017: rename ln_...NONE as ln_...OFF (CONFIG, OPA_SRC, TOP_SRC) ; agrif zoom now only in AGRIF_NORDIC configuration

File:
1 edited

Legend:

Unmodified
Added
Removed
  • branches/2017/dev_merge_2017/NEMOGCM/NEMO/OPA_SRC/DYN/dynadv.F90

    r9490 r9526  
    3030   PUBLIC dyn_adv_init  ! routine called by opa  module 
    3131  
    32    !                                    !* namdyn_adv namelist * 
    33    LOGICAL, PUBLIC ::   ln_dynadv_NONE  !: linear dynamics (no momentum advection) 
     32   !                                   !!* namdyn_adv namelist * 
     33   LOGICAL, PUBLIC ::   ln_dynadv_OFF   !: linear dynamics (no momentum advection) 
    3434   LOGICAL, PUBLIC ::   ln_dynadv_vec   !: vector form 
    3535   INTEGER, PUBLIC ::      nn_dynkeg       !: scheme of grad(KE): =0 C2 ; =1 Hollingsworth 
     
    9595      INTEGER ::   ioptio, ios   ! Local integer 
    9696      ! 
    97       NAMELIST/namdyn_adv/ ln_dynadv_NONE, ln_dynadv_vec, nn_dynkeg, ln_dynadv_cen2, ln_dynadv_ubs 
     97      NAMELIST/namdyn_adv/ ln_dynadv_OFF, ln_dynadv_vec, nn_dynkeg, ln_dynadv_cen2, ln_dynadv_ubs 
    9898      !!---------------------------------------------------------------------- 
    9999      ! 
     
    114114      IF(lwp) THEN                    ! Namelist print 
    115115         WRITE(numout,*) '   Namelist namdyn_adv : chose a advection formulation & scheme for momentum' 
    116          WRITE(numout,*) '      linear dynamics : no momentum advection          ln_dynadv_NONE = ', ln_dynadv_NONE 
     116         WRITE(numout,*) '      linear dynamics : no momentum advection          ln_dynadv_OFF  = ', ln_dynadv_OFF 
    117117         WRITE(numout,*) '      Vector form: 2nd order centered scheme           ln_dynadv_vec  = ', ln_dynadv_vec 
    118118         WRITE(numout,*) '         with Hollingsworth scheme (=1) or not (=0)       nn_dynkeg   = ', nn_dynkeg 
     
    122122 
    123123      ioptio = 0                      ! parameter control and set n_dynadv 
    124       IF( ln_dynadv_NONE ) THEN   ;   ioptio = ioptio + 1   ;   n_dynadv = np_LIN_dyn   ;   ENDIF 
     124      IF( ln_dynadv_OFF ) THEN   ;   ioptio = ioptio + 1   ;   n_dynadv = np_LIN_dyn   ;   ENDIF 
    125125      IF( ln_dynadv_vec  ) THEN   ;   ioptio = ioptio + 1   ;   n_dynadv = np_VEC_c2    ;   ENDIF 
    126126      IF( ln_dynadv_cen2 ) THEN   ;   ioptio = ioptio + 1   ;   n_dynadv = np_FLX_c2    ;   ENDIF 
Note: See TracChangeset for help on using the changeset viewer.