#931 (pH is not well diagnosed in PISCES model) – NEMO

Opened 12 years ago

Closed 12 years ago

#931 closed Bug (fixed)

pH is not well diagnosed in PISCES model

Reported by: cetlod Owned by: nemo
Priority: low Milestone:
Component: TOP Version: v3.4
Severity: Keywords: PISCES, pH
Cc:

Description

The pH as it now diagnosed in PISCES is wrong. The diagnostic in the outputs corresponds to the concentration of ion [H+], not to the pH.

The pH must be calculated as follows : pH =-log10 ([H+])

Commit History (1)

ChangesetAuthorTimeChangeLog
3321cetlod2012-03-05T18:10:55+01:00

trunk:bugfix on pH diagnostic in PISCES, see ticket #931

Change History (1)

comment:1 Changed 12 years ago by cetlod

  • Resolution set to fixed
  • Status changed from new to closed